Tungsten-Rhenium thermocouples were developed to meet the requirements for measuring ultra-high temperatures in
the 2760°C (5000°F) range.
OMEGA makes available three widely used Tungsten-Rhenium thermocouple calibrations. Tungsten versus
Tungsten-26% Rhenium, Tungsten-5% Rhenium versus Tungsten-26% Rhenium and Tungsten-3% Rhenium
versus Tungsten-25% Rhenium.
OMEGA® Tungsten-Rhenium Thermocouples conform to the limits of error listed in the Table: “Limits of Error for
Tungsten-Rhenium Thermocouple Wire combinations.”
Because of the inherent brittleness of unalloyed Tungsten, the Tungsten versus Tungsten-26% Rhenium thermocouples
are more difficult to handle than the Tungsten-5% Rhenium versus Tungsten-26% Rhenium combination.
The average EMF of the W-3% Re/W-25% Re is slightly less than that of W/W-26% Re and slightly more than that
of W-5% Re/W-26% Re. The ductility of W-3% Re is about equal to that of W-5%Re, but superior to that of unalloyed
Tungsten.
All three thermocouple calibrations can be used to 2760°C (5000°F) in hydrogen or inert gas atmospheres and in a
vacuum. They undergo rapid deterioration under oxidizing conditions and should not be used in air or atmospheres
containing oxygen.
OMEGA® Tungsten-Rhenium thermocouples are supplied in 12-inch lengths which corresponds to each leg for a 24"
total length. Longer lead lengths are available, Consult Sales.
Model No.**
Materials
Wire Dia. mm (inches)
T5R-010-12-BW T5R-015-12-BW T5R-020-12-BW
C* Tungsten 5% Re- Tungsten 26% Re
0.25 (.010) 0.38 (.015) 0.50 (.020)
T3R-010-12-BW T3R-015-12-BW T3R-020-12-BW
D Tungsten 3% Re- Tungsten 25% Re
0.25 (.010) 0.38 (.015) 0.50 (.020)
* Most popular of the three Tungsten-Rhenium thermocouples, a large selection of instrumentation is available.
** Tungsten-Rhenium alloy thermocouples are supplied in standard 300 mm (12") lengths, which corresponds to each leg for a
600 mm (24") total length. Change suffix “-12” in model number to indicate additional length required in inches.
NOTE: Butt-Welded Tungsten-Rhenium thermocouples cannot be bent in the butt-welded area. All warranties are voided if the
customer chooses to bend the thermocouple.
† All dollar amounts on this site are shown in US currency.
Note: Other lengths are available please consult sales.
Keywords:Butt-Welded Unsheathed Fine Gage Tungsten-Rhenium Thermocouple, shaft torque measurement