Cart  |  Contact  |  Help  | 
US and Canada1-888-826-6342
International1-203-359-1660

Your Source for Process Measurement & Control

Mini RTD Temperature Transmitter With M12 Connectors

TX-M12-RTD Series

Temperature Transmitter for RTD with M12 Connectors | TX-M12-RTD Series

Temperature Transmitter for RTD with M12 Connectors

$182.00 TX-M12-RTD-C-1

  • bvseo_sdk, net_sdk, 3.1.1.0
  • CLOUD, getAggregateRating, 47ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
RoHS
  • Programmable RTD Transmitter for use with Pt100, 500 or 1000 ohm RTD Sensors
  • M12 Connections Provide Easy Attachment to Your Sensor and Instrumentation
  • Can be used with 2-Wire, 3-Wire or 4-Wire RTD Sensors (See Wiring Information Below)
  • Small Size, 38mm Diameter Housing Weighs Just 100 grams (3 1/2 oz)
  • 4 to 20mA or 0 to 10VDC Output Models Available.
  • Rangeable from -200 to 850°C (-328 to 1862°F)
RTD (PT100)  Probes, Elements and Assemblies - View related products

Description

Omega’s TX-M12-RTD Series RTD transmitters offer improved performance over conventional in-head transmitters yet are a fraction of their size and weight. Integral M12 connectors maintain IP67 protection and connection integrity while allowing for a quick and simple change of sensor. Two models are available with either 4 to 20 mA or 0 to 10 Vdc output. Default scaling for the full output is 0 to 100°C (32 to 212°F), other ranges can be scaled at time of purchase for an additional charge; or the optional USB programming module (USB-CONFIG-UNIT) will allow the end user to perform scaling.

The TX-M12-RTD transmitter is ideal for use with Omega’s 4-wire PR-21, PR-22 and PRS-M12 Series RTD probes, or any RTD probes with an M12 “A” coded pin style connector which connects directly to theTX-M12-RTD sensor input. Other 2-wire, 3-wire or 4-wire RTD probes, as well as slide wire resistance devices, can be easily connected to the TX-M12-RTD transmitter by using a field mountable M12-R-M-FM or M12-S-M-FM plug style connector. Please see the wiring diagrams below for 2-wire, 3-wire and 4-wire RTDs, as well as other slide wire resistance devices.

Don't forget to order an M12 extension cable to connect your transmitter to your process instrumentation.

SPECIFICATIONS
Update Time: 200 mS
Response Time: 0.5 seconds
Warm-up Time: 1 minute to full accuracy
Sensor Connection: 2, 3 or 4-wire M12
Minimum Span: 25°C Thermal Drift
    Pt100: 0.013 Ω/°C
    Pt500/Pt1000: 0.063 Ω/°C
Accuracy: ±0.2°C + (0.05%) + output accuracy
Excitation Current: <200 uA
Lead Resistance Effect: 0.002°C/Ω
Maximum Lead Resistance: 20 Ω per leg
Operating Ambient: -40 to 85°C; 10 to 90% RH (non condensing)
Configuration Ambient: 10 to 30°C
Weight: Approx 100 g 4 to 20 mA Output Model
Output Type: 2-wire, 4 to 20 mA current loop
Output Range: 4.0 to 20.0 mA
Output Connection: M12 connector
Output Limits: 3.8 to 21.5 mA
Accuracy: mA output/2000 or 5 uA (whichever is the greater)
Loop Voltage Effect: 0.2 uA/V
Thermal Drift: 1 uA/°C
Maximum Output Load: [(Vsupply-10)/20] KΩ
Start Up Time 4 Seconds: I out < 4 mA during start up
Power Supply: 8 to 30 Vdc 0 to 10 Vdc Output Model
Output Type: 3-wire voltage
Output Range: Selectable within 0 to 10V
Current Drive: 2 mA max
Output Connection: M12 connector
Output Limits: -0.1 to 10.5V
Accuracy: Voltage output/1000 or 5 mV (whichever is the greater)
Thermal Drift: 1 mV/°C
Minimum Output: Load 5000 Ω
Power Supply: 12 to 30 Vdc

TRANSMITTER SELECTION TABLE
Transmitter Model Transmitter Output Compatible Omega Sensors
TX-M12-RTD-V 0 to 10VDC PR-21…-2, PR-22, P-L-M12
TX-M12-RTD-V-1 0 to 10VDC PR-21…-1, PRS-M12, PR-25AP
TX-M12-RTD-C 4 to 20mA PR-21…-2, PR-22, P-L-M12
TX-M12-RTD-C-1 4 to 20mA PR-21…-1, PRS-M12, PR-25AP

Sensor Input Wiring Diagrams

TX-M12-RTD-C and TX-M12-RTD-V


TX-M12-RTD-C-1 and TX-M12-RTD-V-1
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Star

Most Popular Models!

Part Number/ Desc.
Qty
RoHS
Description
  
TX-M12-RTD-C Star
$182.00
Available In 1 Week
RoHS compliancy undetermined
4 to 20 mA output, RTD Transmitter connects to PR-21...-2 wiring, PR-22 and P-L-M12 sensors
  
TX-M12-RTD-C-1 Star
$182.00
25 In Stock
RoHS compliancy undetermined
4 to 20 mA output, RTD Transmitter connects to PR-21...-1 wiring, PRS-M12 and PR-25AP sensors
  
TX-M12-RTD-V Star
$202.00
Available In 3 Weeks
RoHS compliancy undetermined
0 to 10 Vdc output, RTD Transmitter connects to PR-21...-2 wiring, PR-22 and P-L-M12 sensors
  
TX-M12-RTD-V-1 Star
$202.00
4 In Stock
RoHS compliancy undetermined
0 to 10 Vdc output, RTD Transmitter connects to PR-21...-1 wiring, PRS-M12 and PR-25AP sensors
Click to expand/minimize a list of what others bought with theM12C-SIL-4-S-F-3
Customers also bought
M12C-SIL-4-S-F-3 Star
$12.75
1 In Stock
RoHS compliancy undetermined
Extension cable with straight socket M12 connector and 3 meters of silicone insulation cable
Click to expand/minimize a list of what others bought with thePR-22-3-100-A-1/8-0600-M12
Customers also bought
PR-22-3-100-A-1/8-0600-M12 Star
$46.00
More Than 25 In Stock
RoHS compliant
Pt100 RTD probe, 1.8" diameter x 6" L with overmolded M12 plug connector for use with TX-M12-RTD-C
Accessories
  
USB-CONFIG-UNIT Star
$112.53
2 In Stock
RoHS compliancy undetermined
Configuration Software and interface/cable to allow scaling of transmitters with a PC
  
FS20 Star
$32.00
Available In 3 Weeks
RoHS compliancy undetermined
Factory scaling charge for ranges other than the 0 to100°C, please specify range required in order comments
All amounts shown in USD
Note: Comes complete with transmitter and operator’s manual (USB-CONFIG-UNIT interface cable sold separately).
Ordering Example: (1) TX-M12-RTD-C-1 RTD Transmitter with 4 to 20 mA Output For use with PR-21, PRS-M12 and PR-25AP Sensors, $182.00  plus (1) TX-M12-RTD-V-1 RTD Transmitter with 0 to 10VDC Output For use with PR-21, PRS-M12 and PR-25AP Sensors, $202.00, $182.00 + 202.00 = $384.00

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Output Configuration select from:
-C for 4 to 20mA Output
-V for 0 to 10VDC Output

(2) Wiring Configuration select from:
Nothing(leave field blank) for -2 wiring for PR-22 and P-L-M12 sensors
-1 for -1 wiring for PRS-M12 and PR-25AP sensors
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download Smart Transmitter (4-20ma)
Download Smart Transmitter(Voltage)
  • bvseo_sdk, net_sdk, 3.1.1.0
  • CLOUD, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;