Small Economical Transmitters |
| TX66A |
|
 |
|
|
Small Economical TemperatureTransmitters
 |
| Click for larger image. |
|
|
|
|
| |
Small, Economical
|
| |
2-Wire, 4 to 20 mA output
|
| |
Thermocouple, RTD, and mV Inputs
|
| |
Automatic Cold Junction Compensation
|
| |
Automatic Self-Calibration
|
View related products - Transmitters
|
| |
|
|
|
 |
The TX66 "smart" transmitter offers isolation, linearization, automatic temperature compensation, automatic self-calibration, and easy-to-use menus. These compact units accept a large number of inputs. The optional 1-line display will fit within the same footprint as the transmitter. The 2-line plug-in display is slightly larger, with two push buttons and LCD glass. Both displays are easily field mounted. At least one display is required to set up the transmitter.
SPECIFICATIONS
Linearization: ±0.05°C
Output:
Analog: 2-wire
Digital: 4 to 20 mA
Minimum Output Range: None
Output Rezolution:
Analog: 3.5 µA
Digital: 4 significant digits
Accuracy:
Digital: ±0.03% of the mV or equivalent reading or the accuracy from the table below, whichever is greater
Analog: Digital accuracy plus ±4 µA, typical, ±8 µA max
Repeatability: One half of accuracy
Failsafe: User-programmable for high, low, or off
Operating Temp Range:
Transmitter: -40 to 85°C (-40 to 185°F)
Display: -20 to 70°C (-4 to 158°F) 0 to 100% RH (non-condensing)
Isolation: 500 Vdc or Vac p-p; operating input-output voltage: 250 Vac p-p or ±250 Vdc
Power and Load: 12 to 48 Vdc; VSUPPLY (MIN) = 12 + (RLOAD in kΩ) x 23 mA
Common-Mode Rejection: 120 dB
Reverse Polarity Protection: 42 Vdc applied with either polarity
Dimensions: 41 mm H x 61 Dia. (1.6 x 2.4")
Weight: 227 g (8 oz)
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes with complete operator’s manual
Ordering Example: (1) TX67A Intrinsically safe transmitter, $340
|
|
 |
|
 |
|  |
|
Back to top
|
|