Miniature Low-Cost Temperature Transmitters

  
5 year warranty CE
 
Temperature Transmitters, Miniature Low Cost
:Miniature Low-Cost Temperature Transmitters
Click for larger image.
   
$ 109.00  TX91A-J2
Two-Wire Transmitter
4-20 mAdc Output
±0.1% Accuracy
Upscale Break Protection
Non-Isolated
Mountable in any Standard Protection Head
Accepts J, K, T, E Thermocouple or 100 ohm Platinum RTD Inputs

View related products - Signal Conditioners/Transmitters

Click to scroll below to order See Specs PDF Manuals View a printer friendly page

The non-isolated TX90A Series transmitters convert thermocouple or RTD signals into a 4 to 20 mA dc signal output that is directly referenced to the mV input of a thermocouple or resistance of a 100 Ohm platinum RTD.

For thermocouple transmitters, the 4 to 20mA output is not linearized. T/C transmitters are available for type K, J, T, and E with color coding for each T/C type. The transmitters for RTD’s are available with the 4 to 20mA output directly proportional to the input resistance or with the 4 to 20mA output linearized to tempearature.

Note, RTD’s are slightly non-linear with the resistance diverging from actual temperature by approximately 1% at the mid point of full scale. (For linearized RTD transmitters, specify “RTD-L”. Non-linearized transmitters are the more popular choice).

The TX90A transmitters mount directly within OMEGA’s standard protection heads for connection to your sensor. OMEGA also provides complete thermocouple and RTD assemblies.

Specifications
Output Range: 4 to 20 mA dc
Zero and Span Adjustment Range: ±25% for °F and ±10% for °C
Accuracy: ±0.1% of FS (includes effects of linearity, hysteresis and repeatability) referenced to the mV input
Operating Temperature Range: -40 to 85°C (-40 to 185°F)
Storage Temperature Range: -46 to 121°C (-50 to 250°F)
Max Loop Resistance: (Vs – 8) / 0.020A
Supply Voltage: 8-50 Vdc, 24V nominal
Dimensions: 44.5 D x 31.75 mm H (1.75 x 1.25"); height includes terminal strip

Range Codes
TX91ATX92ARange
JKTERTDRTD-L 
11-L-40 to 60°C (-40 to 140°F)
J2K2T2E222-L-18 to 93°C (0 to 200°F)
J3K3T3E333-L-18 to 149°C (0 to 300°F)
J4K4T4E444-L-18 to 260°C (0 to 500°F)
J5K5T5E555-L-18 to 399°C (0 to 750°F)
J6K6E666-L-18 to 538°C (0 to 1000°F)
J7K7T7E777-L0 to 100°C (32 to 212°F)
J8K8T8E888-L0 to 150°C (32 to 302°F)
J9K9T9E999-L0 to 250°C (32 to 482°F)
J10K10T10E101010-L0 to 400°C (32 to 752°F)
J11K11E110 to 500°C (32 to 932°F)


To Order (Specify Model Number)    
expand listWhat Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 Part Number   Availability   Price   Description    Qty.
 Thermocouple Transmitters
    TX91A-K2 In Stock   $109.00    TYPE K T/C transmitter, Range -18 to 93°C (0 to 200°F)  
    TX91A-J4 In Stock   $109.00    TYPE J T/C transmitter, Range -18 to 260°C (0 to 500°F)  
    TX91A-K4 In Stock   $109.00    TYPE K T/C transmitter, Range -18 to 260°C (0 to 500°F)  
    TX91A-T4 In Stock   $109.00    TYPE T T/C transmitter, Range -18 to 260°C (0 to 500°F)  
    TX91A-E4 In Stock   $109.00    TYPE E T/C transmitter, Range -18 to 260°C (0 to 500°F)  
    TX91A-K6 In Stock   $109.00    TYPE K T/C transmitter, Range -18 to 538°C (0 to 1000°F)  
 RTD Transmitters
Click to expand/minimize a list of what others bought with the TX92A-1  TX92A-1 In Stock   $109.00    RTD transmitter 100 ohm, Range -40 to 60°C (-40 to 140°F)  
    TX92A-2 In Stock   $109.00    RTD transmitter 100 ohm, Range -18 to 93°C (0 to 200°F)  
Click to expand/minimize a list of what others bought with the TX92A-3  TX92A-3 In Stock   $109.00    RTD transmitter 100 ohm, Range -18 to 149°C (0 to 300°F)  
Click to expand/minimize a list of what others bought with the TX92A-4  TX92A-4 In Stock   $109.00    RTD transmitter 100 ohm, Range -18 to 260°C (0 to 500°F)  
    TX92A-5 In Stock   $109.00    RTD transmitter 100 ohm, Range -18 to 399°C (0 to 750°F)  
    TX92A-6 In Stock   $109.00    RTD transmitter 100 ohm, Range -18 to 538°C (0 to 1000°F)  
 RTD Probe and Transmitter Assembly
    PRTXA-1-12 1 Week   $215.00    RTD transmitter with 12 inch Probe and Head, 100 ohm, Range -40 to 60°C (-40 to 140°F)  
    PRTXA-2-12 1 Week   $215.00    RTD transmitter with 12 inch Probe and Head, 100 ohm, Range -18 to 93°C (0 to 200°F)  
    PRTXA-3-12 1 Week   $215.00    RTD transmitter with 12 inch Probe and Head, 100 ohm, Range -18 to 149°C (0 to 300°F)  
    PRTXA-4-12 1 Week   $215.00    RTD transmitter with 12 inch Probe and Head, 100 ohm, Range -18 to 260°C (0 to 500°F)  
    PRTXA-5-12 1 Week   $215.00    RTD transmitter with 12 inch Probe and Head, 100 ohm, Range -18 to 399°C (0 to 750°F)  
    PRTXA-6-12 1 Week   $215.00    RTD transmitter with 12 inch Probe and Head, 100 ohm, Range -18 to 538°C (0 to 1000°F)  
 TC Probe and Transmitter Assembly
    NB1TXA-J4 1 Week   $171.00    TX91A-J4 Transmitter in Cast Iron Head with 12"L, 1/4" O.D., ungrounded junction, 304SS sheath probe.  
    NB1TXA-K2 1 Week   $171.00    TX91A-J2 Transmitter in Cast Iron Head with 12"L, 1/4" O.D., ungrounded junction, 304SS sheath probe.  
    NB1TXA-T4 1 Week   $171.00    TX91A-T4 Transmitter in Cast Iron Head with 12"L, 1/4" O.D., ungrounded junction, 304SS sheath probe.  
    NB1TXA-E6 1 Week   $171.00    TX91A-E6 Transmitter in Cast Iron Head with 12"L, 1/4" O.D., ungrounded junction, 304SS sheath probe.  
    NBSTXA-J4 2 Weeks   $171.00    TX91A-J4 Transmitter in Aluminum Head with 12"L, 1/4" O.D., ungrounded junction, 304SS sheath probe.  
    NBSTXA-K2 2 Weeks   $171.00    TX91A-K2 Transmitter in Aluminum Head with 12"L, 1/4" O.D., ungrounded junction, 304SS sheath probe.  
 Accessories
Click to expand/minimize a list of what others bought with the TX90-BR  TX90-BR In Stock   $18.00    Mounting Bracket for DIN Rail or Mounting to Surface  
Click to expand/minimize a list of what others bought with the TX90-DIN  TX90-DIN In Stock   $27.50    DIN rail mounting adaptor  
Click to expand/minimize a list of what others bought with the RT  RT In Stock   $30.00    1.2 m (48") mounting track  
Click to expand/minimize a list of what others bought with the RAIL-35-2  RAIL-35-2 In Stock   $19.00    2 m (6.5') section 35 mm DIN rail  
Click to expand/minimize a list of what others bought with the PSR-24L  PSR-24L In Stock   $60.00    Regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, stripped leads, UL  
Click to expand/minimize a list of what others bought with the PSR-24S  PSR-24S In Stock   $60.00    Regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL  
    PSR-24L-230 In Stock   $60.00    Regulated power supply, 24 Vdc, 400 mA, stripped leads, 230 Vac input, CE  
All dollar amounts on this site are shown in US currency.

 Note: Range Code "T6" is not available

 Ordering Example: (1) TX91A-J2 Specifies a Type J transmitter, with 0 to 200°F range, $109.00
 Part Number Builder
(1) (2) (3) (4) (5)
-
  
Option Descriptions
(1) Transmitter Type
  Select
TX91A for Thermocouple transmitter only
TX92A for RTD transmitter only
NB1TXA for Thermocouple transmitter with Cast-Iron head and 12 inch probe
NBSTXA for Thermocouple transmitter with Aluminum head and 12 inch probe
PRTXA for RTD transmitter with Cast-Iron head and 12 inch RTD probe
(2) Input Type
  Select
Nothing(leave field blank) for RTD transmitter
J for Type J thermocouple (Iron-Constantan)
K for Type K thermocouple (Chromega®-Alomega®)
T for Type T thermocouple (Copper-Constantan) (ranges 6 and 11 excluded)
E for Type E thermocouple (Chromega®-Constantan)
(3) Range for transmitter
  Select
Nothing(leave field blank) for RTD probe assemblies
1 for -40 to 140°F (RTD only)
2 for 0 to 200°F
3 for 0 to 300°F
4 for 0 to 500°F
5 for 0 to 750°F
6 for 0 to 1000°F (Thermocouple J K E and RTD only)
7 for 0 to 100°C
8 for 0 to 150°C
9 for 0 to 250°C
10 for 0 to 400°C
11 for 0 to 500°C (Thermocouple J K E only)
(4) Range for RTD probe assemblies only
  Select
Nothing(leave field blank) for single transmitter units
1-12 for -40 to 140°F (RTD)
2-12 for 0 to 200°F (RTD)
3-12 for 0 to 300°F (RTD)
4-12 for 0 to 500°F (RTD)
5-12 for 0 to 750°F (RTD)
6-12 for 0 to 1000°F (RTD)
7-12 for 0 to 100°C (RTD)
8-12 for 0 to 150°C (RTD)
9-12 for 0 to 250°C (RTD)
10-12 for 0 to 400°C (RTD)
(5) Linearized RTD
  Select
Nothing(leave field blank) for standard non-linearized transmitter
-L for for the 4-20mA output linearized to temperature and selected range
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Manual
 Product Manual
   Download  TX92A - RTD Transmitter Manual
   Download  TX91A - Mini Temperature Transmitter
   
Keywords:Miniature Temperature Transmitter, low-cost, complete probe assembly, 4-20 mA transmitters, protection head assemblies, transmit thermocouple signals, RTD transmitter, thermocouple transmitter, 4-20 mA transmitter, linearized, clamp on ultrasonic flow meters liquid level controller

   Back to topBack to top

© Copyright 2003-2013  |  OMEGA ENGINEERING, Inc.
OMEGA
Privacy Statement  |  Terms and Conditions
   MXV MMV | 71
VerisignAmex, Visa, Mastercard
Skip to navigation


Home Quick Order Products Literature My Omega Omega Info Contact Us Cart Help Global