Miniature Low-Cost Temperature Transmitters |
| |
|
 |
|
|
Temperature Transmitters, Miniature Low Cost
 |
| Click for larger image. |
|
|
|
|
|
|
 |
The non-isolated TX90A Series transmitters convert thermocouple or
RTD signals into a 4 to 20 mA dc signal output that is directly
referenced to the mV input of a thermocouple or resistance of a 100
Ohm platinum RTD.
For thermocouple transmitters, the 4 to 20mA output is not linearized. T/C
transmitters are available for type K, J, T, and E with color coding for each
T/C type. The transmitters for RTD’s are available with the 4 to 20mA
output directly proportional to the input resistance or with the 4 to 20mA
output linearized to tempearature.
Note, RTD’s are slightly non-linear with the resistance diverging from
actual temperature by approximately 1% at the mid point of full scale. (For
linearized RTD transmitters, specify “RTD-L”. Non-linearized transmitters
are the more popular choice).
The TX90A transmitters mount directly within OMEGA’s standard
protection heads for connection to your sensor. OMEGA also provides
complete thermocouple and RTD assemblies.
Specifications
Output Range: 4 to 20 mA dc
Zero and Span Adjustment Range: ±25% for °F and ±10% for °C
Accuracy: ±0.1% of FS (includes effects of linearity, hysteresis and
repeatability) referenced to the mV input
Operating Temperature Range: -40 to 85°C (-40 to 185°F)
Storage Temperature Range: -46 to 121°C (-50 to 250°F)
Max Loop Resistance: (Vs – 8) / 0.020A
Supply Voltage: 8-50 Vdc, 24V nominal
Dimensions: 44.5 D x 31.75 mm H (1.75 x 1.25"); height includes terminal strip
Range Codes
| TX91A | TX92A | Range |
| J | K | T | E | RTD | RTD-L | |
| – | – | – | – | 1 | 1-L | -40 to 60°C (-40 to 140°F) |
| J2 | K2 | T2 | E2 | 2 | 2-L | -18 to 93°C (0 to 200°F) |
| J3 | K3 | T3 | E3 | 3 | 3-L | -18 to 149°C (0 to 300°F) |
| J4 | K4 | T4 | E4 | 4 | 4-L | -18 to 260°C (0 to 500°F) |
| J5 | K5 | T5 | E5 | 5 | 5-L | -18 to 399°C (0 to 750°F) |
| J6 | K6 | – | E6 | 6 | 6-L | -18 to 538°C (0 to 1000°F) |
| J7 | K7 | T7 | E7 | 7 | 7-L | 0 to 100°C (32 to 212°F) |
| J8 | K8 | T8 | E8 | 8 | 8-L | 0 to 150°C (32 to 302°F) |
| J9 | K9 | T9 | E9 | 9 | 9-L | 0 to 250°C (32 to 482°F) |
| J10 | K10 | T10 | E10 | 10 | 10-L | 0 to 400°C (32 to 752°F) |
| J11 | K11 | – | E11 | – | – | 0 to 500°C (32 to 932°F) |
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Range Code "T6" is not available
Ordering Example: (1) TX91A-J2 Specifies a Type J transmitter, with 0 to 200°F range, $109.00
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Transmitter Type
|
| |
Select TX91A for Thermocouple transmitter only TX92A for RTD transmitter only NB1TXA for Thermocouple transmitter with Cast-Iron head and 12 inch probe NBSTXA for Thermocouple transmitter with Aluminum head and 12 inch probe PRTXA for RTD transmitter with Cast-Iron head and 12 inch RTD probe
|
(2)
|
Input Type
|
| |
Select Nothing(leave field blank) for RTD transmitter J for Type J thermocouple (Iron-Constantan) K for Type K thermocouple (Chromega®-Alomega®) T for Type T thermocouple (Copper-Constantan) (ranges 6 and 11 excluded) E for Type E thermocouple (Chromega®-Constantan)
|
(3)
|
Range for transmitter
|
| |
Select Nothing(leave field blank) for RTD probe assemblies 1 for -40 to 140°F (RTD only) 2 for 0 to 200°F 3 for 0 to 300°F 4 for 0 to 500°F 5 for 0 to 750°F 6 for 0 to 1000°F (Thermocouple J K E and RTD only) 7 for 0 to 100°C 8 for 0 to 150°C 9 for 0 to 250°C 10 for 0 to 400°C 11 for 0 to 500°C (Thermocouple J K E only)
|
(4)
|
Range for RTD probe assemblies only
|
| |
Select Nothing(leave field blank) for single transmitter units 1-12 for -40 to 140°F (RTD) 2-12 for 0 to 200°F (RTD) 3-12 for 0 to 300°F (RTD) 4-12 for 0 to 500°F (RTD) 5-12 for 0 to 750°F (RTD) 6-12 for 0 to 1000°F (RTD) 7-12 for 0 to 100°C (RTD) 8-12 for 0 to 150°C (RTD) 9-12 for 0 to 250°C (RTD) 10-12 for 0 to 400°C (RTD)
|
(5)
|
Linearized RTD
|
| |
Select Nothing(leave field blank) for standard non-linearized transmitter -L for for the 4-20mA output linearized to temperature and selected range
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
 |
|
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |