1-888-TC-OMEGA (1-888-826-6342) US and Canada
1-203-359-1660 INTERNATIONAL
Home >> Flow and Level Produ... >> Sanitary >> Sanitary Sensors >> TX94A-SS Series Temperature Transmitter
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation

RTD Temperature Transmitter - 316 Stainless Steel Construction

TX94A-SS Series Temperature Transmitter   
 
RTD PT100 Temperature Transmitter
TX94A-SS Series Temperature Transmitter:RTD Temperature Transmitter - 316 Stainless Steel Construction
   
$195.00  TX94A-1-SS-M12F-1
PLACE ORDER
Ideal for Wash-down, Outdoor, Sanitary or Marine Environments
Compact Design Attaches Directly to Most 3-Wire and 4-Wire, Pt100, 0.00385 Curve Sanitary Probes and Sensors with M12 Style Connectors
True 2-Wire Operation, Loop Powered 4 to 20 mA Output
Sealed Signal Conditioner Built Into NEMA 4X (IP67) 316 Stainless Steel Housing
±0.1% FS Accuracy, High Repeatability, and Stability
Both Zero and Span Adjustments for Field Calibration
Provides “Upscale” Break Detection and Compensates for Long Lead Wires

View related products - Sanitary

Click to scroll below to order See Specs PDF Related Items View a printer friendly page

Loop Powered! The OMEGA® 2-wire TX94A-SS Series temperature transmitters are high-performance, industrial transmitters designed for direct connection to most CIP (clean-inplace) Sanitary Pt100 probes and sensors that incorporate a M12 style connection. All models feature a miniature signal conditioner built into a sealed stainless steel connector housing. The signal conditioner converts the resistive change of a 100 Ω, 0.00385 RTD probe or sensor into an industry-standard 2-wire, 4 to 20 mA analog output across a dedicated temperature range. Output connection is also a standard M12 connector.

M12 RTD SENSOR WIRING
Wiring option #1Wiring option #2

The TX94A-SS transmitter is provided with two RTD wiring configurations as shown. The wiring style is identified at the end of the model number by either a "-1" or "-2". If used with an Omega PR-21 sensor, then the "-1" or "-2" selection should match the final charecters following the "-M12" in the sensor model number (ie: PR-21A-3-100-A-1/4-0600-M12-1). When using the transmitter with an Omega PR-22 style RTD, then please select the -2 wiring configuration.
Examples:
For use with a PR-21A-3-100-A-1/4-0600-M12-1, use an TX94A-2-SS-M12F-1 Transmitter (Range is -18 to 93°C).
For use with a PR-22-3-100-A-M6-250-M12 sensor, use an TX94A-2-SS-M12F-2 Transmitter (Range is -18 to 93°C).


SPECIFICATIONS
Supply Voltage: 8 to 35 Vdc; (24 Vdc recommended)
Max Load: Rmax (Ω) = (Vsupply - 8V)/0.02 A
Output: Linearized 4 to 20 mA
Accuracy: ±0.1% FS (includes effects of linearity, hysteresis and repeatability)
Frequency Response: 3 dB @ 3Hz
Range:
    1: -40 to 49°C (-40 to 120°F)
    2: -18 to 93°C (0 to 200°F)
    3: -18 to 149°C (0 to 300°F)
    4: -18 to 260°C (0 to 500°F)
Input: 3-wire, Pt100 (α = 0.00385), 4-wire RTD compatible Probe/Sensor Input
Connection:
    TX94A-SS-M12M: M12 style, 4-pin male
    TX94A-SS-M12F: M12 style, 4-pin female
Transmitter Operating Temp: -40 to 85°C (-40 to 185°F)
Output Connection (All Models): M12 style (order cable from table below)
Housing: 316 stainless steel, polished mirror finish
Approvals: CE marked
Dimensions: 51 H x 38 mm D (2.0 x 1.50")


To Order (Specify Model Number)
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 Part Number   Availability   Price   Description    Qty.
    TX94A-1-SS-M12M-1 In Stock   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -40 to 49°C (-40 to 120°F)  
    TX94A-1-SS-M12M-2 In Stock   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -40 to 49°C (-40 to 120°F)  
    TX94A-2-SS-M12M-1 2 Weeks   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 93°C (0 to 200°F)  
    TX94A-2-SS-M12M-2 In Stock   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 93°C (0 to 200°F)  
    TX94A-3-SS-M12M-1 In Stock   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 149°C (0 to 300°F)  
    TX94A-3-SS-M12M-2 2 Weeks   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 149°C (0 to 300°F)  
    TX94A-4-SS-M12M-1 2 Weeks   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 260°C (0 to 500°F)  
    TX94A-4-SS-M12M-2 2 Weeks   $195.00    4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 260°C (0 to 500°F)  
    TX94A-1-SS-M12F-1 In Stock   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -40 to 49°C (-40 to 120°F)  
    TX94A-1-SS-M12F-2 In Stock   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -40 to 49°C (-40 to 120°F)  
    TX94A-2-SS-M12F-1 2 Weeks   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 93°C (0 to 200°F)  
    TX94A-2-SS-M12F-2 In Stock   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 93°C (0 to 200°F)  
    TX94A-3-SS-M12F-1 In Stock   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 149°C (0 to 300°F)  
    TX94A-3-SS-M12F-2 In Stock   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 149°C (0 to 300°F)  
    TX94A-4-SS-M12F-1 2 Weeks   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 260°C (0 to 500°F)  
    TX94A-4-SS-M12F-2 2 Weeks   $195.00    4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 260°C (0 to 500°F)  
 Accessories
Click to expand/minimize a list of what others bought with the PSR-24S  PSR-24S In Stock   $65.00    Regulated power supply, 24 Vdc, 400 mA, screw terminal  
Click to expand/minimize a list of what others bought with the PSR-24L  PSR-24L In Stock   $65.00    Regulated power supply, 24 Vdc, 400 mA, UL, stripped leads  
    PSR-24L-230 In Stock   $65.00    Regulated power supply, 24 Vdc, 400 mA, stripped leads, 230 Vac input, CE  
    CAL-3    Consult sales   NIST traceable calibration with data  
 Output Cables
Click to expand/minimize a list of what others bought with the M12C-PUR-4-S-F-5  M12C-PUR-4-S-F-5 In Stock   $16.50    Cable, M12, 4-pin female, polyurethane jacket, 5 m (16.4') long  
Click to expand/minimize a list of what others bought with the M12C-PVC-4-S-F-5  M12C-PVC-4-S-F-5 In Stock   $15.50    Cable, M12, 4-pin female, PVC jacket, 5 m (16.4') long  
All dollar amounts on this site are shown in US currency.

 Note: The TX94A-SS series has not been designed for use in medical or nuclear applications, nor flammable or explosive environments.
 Ordering Example: (1) TX94A-2-SS-M12F-2 4 to 20 mA output transmitter with -18 to 93°C (0 to 200°F) temperature range, M12 style 3-pin male connection, $195.00,  plus (1) PSR-24L Power supply, $65.00, $195.00 + 65.00 = $260.00

 Related Links - Related Products
 Related Products
PR-21 Series PR-21 Series:
Vibration Resistant Platinum RTD (PT100) Sensor with M12 Connector and Mounting Thread
PR-22 Series PR-22 Series:
PT100 RTD Probes with M12 Molded Connectors
PRS-M12 Series Sanitary RTD Sensors PRS-M12 Series Sanitary RTD Sensors:
3-A Approved Sanitary RTD Sensor with M12 Connector for use in Sanitary or Hygienic Clean-In-Place (CIP) Applications
PRS-TW-M12 Series Sanitary RTD Sensors PRS-TW-M12 Series Sanitary RTD Sensors:
Sanitary RTD Sensors with Thermowell Removable Sensor M12 Connector for use in CIP Clean-In-Place Processes
M12C Series Extension Cables M12C Series Extension Cables:
DC Cable Assemblies for Probes, Sensors and Transmitters
   
Keywords:4 to 20mA Temperature Transmitter in Stainless Steel Housing for Use with Pt100 Platinum RTD Sensors with M12 Connections, room heater rotary shaft encoder tubular heating used borescope

   Back to topBack to top




MMV | 79 | 013