The LCM101 & LCM111 are also available in standard configurations, with 0-25 to 0-40,000 lb ranges and standard threads.
Please see the LC101 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS Excitation: 10 Vdc, 15 Vdc max
Output: 3 mV/V ±.0075 mV/V
Linearity: ±0.03% FSO
Hysteresis: ±0.02% FSO
Repeatability: ±0.01% FSO
Zero Balance: ±1% FSO
Agency Approval: FM Intrinsically Safe IS/I.II.III/1/CDEFG — Standard
Operating Temp Range: -40 to +93°C (-40 to 200°F)
Compensated Temp Range: 17 to 71°C (60 to 160°F)
Thermal Effects: Zero: 0.0018% FSO/°C Span: 0.0018% FSO/°C
Safe Overload: 150% of Capacity
Ultimate Overload: 300% of Capacity
Input Resistance: 350 ±10 Ohms
Output Resistance: 350.±10 Ohms
Full Scale Deflection: 0.25 to 0.50 mm
Construction: 17-4 PH Stainless Steel
Electrical (LCM101): <100 kg = 9 m (30 ft) 24 AWG; =250 kg 4.6 m (30 ft) 20 AWG; =1500 kg 4.6 m (15 ft) 20 AWG 4-conductor shielded cable
Mating Connector (LCM111): 100 kgF and below = PT06F8-4S, 250 kgF and above = PT06F10-6S (not included)
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: To order connector style, change Model No. to LCM111, no extra charge. Mating Connector, PT06F10-6S $26.50 or PT06F8-4S $24.00, sold separately. (OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) LCM101-2K is a ±2,000 kgF capacity cable style "S" beam load cell = $445
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |