| Ultrasonic Flow Meter Types | |
![]() |
Ultrasonic Flowmeter with Totalization These ultrasonic flowmeters are for applications with 100 PPM of 100 microns in size particulates or bubbles in the liquid. They are good for pipe sizes 0.25 to 120". These flow meters are used for flow measurement applicatons of 0.1 to 30 FPS. The FD6000 series has a standard display and 4 to 20 mA, Relay and 12 V pulse outputs. |
![]() |
Ultrasonic Flow Meter The FD-301A Series ultrasonic flow meter transmitter systems are designed for use where a sensor cannot be installed in the process. For liquids with suspended solids or aeration, standard and enhanced models. Available in non-invasive fixed position style. The FD-301A is an ideal doppler flow measurement solution. They are well suited for full pipes of liquid that contain at least 100 ppm of 100 micron or larger suspended particles or gas bubbles which act as sound “reflectors” and are necessary for operation. Ideal uses for this technology include: flow measurement of wastewater sewage, reactivated sludge, waste activated sludge, primary sludge, slurries, crude oils, lime slurries, phosphates and pulp stock. |
![]() |
Portable Ultrasonic Flow Meter The FD610 Series ultrasonic flow meter features advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed piping systems. The FD610 Series utilizes a non-invasive clamp-on transducer which is placed on the outside of a pipe. Within seconds, the large 18 mm (0.7") LCD provides stable flowrate readings in feet per second or meters per second. This product operates on metal or plastic pipes containing liquids with more than 100 ppm of 100 micron or larger suspended solids or entrained gases. |
![]() |
Clean Liquid Ultrasonic Flow Meter The FD-7000 is used to measure the flow of liquids containing suspended solids or bubbles, the transducers are mounted on a straight run of pipe in the same manner as other ultrasonic meters. In applications where insufficient “reflectors” exist (a condition indicated by a low reading on the FD-7000’s Flow Analyzer bar graph), the transducers are relocated to a point in the piping where non-symmetrical hydraulic turbulence will be present – ideally just downstream of a 90-degree elbow. |
| ^top |
| Automation |Accelerometers | Calibrators | Cartridge Heaters | Chart Recorders | Cryogenics | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Flexible Heaters | Flowmeters | Glass Bulb Thermometers | Heaters | Humidity Measurement | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells |
Magnetic Flow Meters | Panel Meters | Pressure Gauges | Pressure Transducers | Rotameters | RTD
| Signal Conditioners | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Transmitters | Thermistors | Thermocouple |
Thermocouple Wire | Thermowell | Ultrasonic Flow Meters ©2003-2008 Omega Engineering |