A temperature calibrator todayneeds to be versatile and meeta wide range of requirements. Itshould be an easily portable deviceto cope with frequently changingoperation locations, as in multipletest bays or in production locations.A calibrator should also be equallysuitable for stationary use in themeasurement lab or in testing andinspection. To meet these demands,these calibrators are lightweightand easy-to-use at each site. Fivetemperature calibrators are availableto cover the range from -35 to 650°C(-31 to 1202°F) and wet or drycalibration requirements.
• Dry Block Calibrator: TCL-650S-D, ambient to 650°C (1202°F) • Dry Block Calibrator: TCL-165S-D, -35 to 165°C (-31 to 329°F) • Micro Bath Calibrator: TCL-M165S-B, -35 to 165°C (-31 to 329°F) • Micro Bath Calibrator: TCL-M255S-B, ambient to 255°C (491°F)
Why Calibrate? Temperature sensorsare subject to mechanical, thermaland chemical stresses. This resultsin a drift the longer the sensors arein use. Only the regular calibrationof the sensors provides informationon the difference between the actualtemperature and the measuredtemperature and makes the specificdrift visible. This data can be criticalto maintaining a stable processoperation.OMEGA™ Dry block calibrators andmicro bath calibrators are one of thebest means to check and calibratea wide range of temperaturemeasuring instruments andtemperature sensors. Mechanical,electro-mechanical or electronicmeasurement equipment can bechecked with ease. These compactand durable calibrators are easy totransport, user-friendly and offerall the features required for thespecific test.
Specifications Control Sensor: Switchable internal/external Micro Bath Temperature Range: -35 to 165°C (-31 to 329°F) Tolerance: ±0.1°C (±0.18°F) Stability: ±0.05°C (±0.09°F) Measurement Zone: 110 to 150 mm (4.33 to 5.91") DRY BLOCK Temperature Range: -35 to 165°C (-31 to 329°F) Tolerance: ±0.3°C (±0.54°F) Stability: ±0.05°C (±0.09°F) Measurement Zone: 123 to 163 mm (4.84 to 6.42") Infrared Temperature Range: -35 to 165°C (-31 to 329°F) Tolerance: ±0.5°C (±0.9°F) Stability: ±0.05°C (±0.09°F) Measurement Zone: 110 mm (4.33") Surface Temperature Range: -25 to 150°C (-13 to 302°F) Tolerance: ±1°C (±1.8°F) Stability: ±0.2°C (±0.36°F) Block: 60 mm (2.36") diameter,170 mm (6.69") depth Display: 178 mm (7") bright colortouch screen, 120 to 140° viewingangle Units: C°/F° switchable Display Range: -50 to 165°C (-58 to 329°F) Resolution: 0.1/0.01/0.001°C (0.18/0.02/0.002°F) Dimensions Width: 210 mm (8.27") Height: 380 x 50 mm (14.96 x 1.97") Depth: 300 mm (11.81") Weight: Approximately 13 kg (28.7 lb) Power Supply: 100 to 240 Vac, 50/60 Hz Power Consumption: Approximately 400 VA