The FMG600 Series electromagnetic flow meters are designed for measurement of conductive liquids. The FMG600 magmeters have no moving parts and a PTFE lining, they can handle applications involving wastewater, pulp, food, and slurries. Standard outputs include analog, frequency, and RS485 communications. Optional sanitary tri-clamp mounting allows use of the FMG600 flow meters in applications not previously open to magmeters. Local- and remote-display models are available.
NOTE: HEAVY WEIGHT - NO UPS - MOTOR FREIGHT ONLY!!! OVERWEIGHT SHIPPING CHARGES WILL APPLY FOR THIS PRODUCT. IF ORDERED ON-LINE INTERNET SALES WILL CONTACT YOU AFTER ORDER PLACEMENT UNLESS YOU OPT TO CHARGE FREIGHT TO YOUR CARRIER ACCOUNT.
SPECIFICATIONS Flange Sizes: 150# ANSI: 19 to 305 mm (¾ to 12") Sanitary Tri-Clamp: 13 to 305 mm (½ to 12") Maximum Pressure: 145 psi Minimum Conductivity: 20 µS Electrode Material: Hastelloy C4 (standard), tantalum (TGE optional) Environmental Temperature: -5 to 55°C (23 to 131°F) Sensor Lining: PTFE Electronics Housing: Local or remote (optional) Liquid Temperature: 0 to 50°C (32 to 122°F) STD, 0 to 150°C (32 to 302°F) with remote electronics Empty Pipe Alarm: 2" and larger sizes (EPD optional) Accuracy: ±0.5% from 5 to 100% Qs, ±1% from 1 to 5% Qs Range: 0.1 to 10 m/s (0.328 to 32.81 fps) Outputs: Adjustable from 0.1 to 1000 gallons/pulse Current: 4 to 20 mA with galvanic isolation Frequency: 0 to 1000 Hz with galvanic isolation Communications: RS485 Power: 24 Vdc, 115/230 Vac switchable (optional) Consumption: 15 VA Protection: IP67 Storage Temperature and Humidity: -10 to 70°C (14 to 158°F) at max; relative humidity 70%
Does this meter require calibration after purchase? If, so how often and by who can perform the calibration.
Asked by: Jerald Mitchell
Thank you for your inquiry about the magnetic flow meter. This meter will factory calibrated prior to shipping and requires an annual calibration and returned to Omega who will calibrate.