Call us at 1-888-826-6342
Thermocouple shielded extension cable with 4 to 24 pairs plus drain wire. K, J, or T calibration. PVC insulation and jacket.
Product Number | Category | Temperature range | Wire Gauge | Thermocouple Calibration Type | Cable Type | Conductor type | Number of Pairs | Conductor Insulation | Overall Insulation | Overbraiding Type | Special Limit of error | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
0 to 105°C (32 to 220°F)
|
24 AWG
|
T
|
Extension Wire
|
Stranded
|
20
|
Polyvinyl (PVC)
|
Polyvinyl (PVC)
|
None
|
No
|
ANSI (Standard)
|
Multi Pair
|
|
Thermocouple
|
0 to 105°C (32 to 220°F)
|
20 AWG
|
J
|
Extension Wire
|
Solid
|
4
|
Polyvinyl (PVC)
|
Polyvinyl (PVC)
|
None
|
No
|
ANSI (Standard)
|
Multi Pair
|
|
Thermocouple
|
0 to 105°C (32 to 220°F)
|
20 AWG
|
K
|
Extension Wire
|
Solid
|
4
|
Polyvinyl (PVC)
|
Polyvinyl (PVC)
|
None
|
No
|
ANSI (Standard)
|
Multi Pair
|
|
Thermocouple
|
0 to 105°C (32 to 220°F)
|
20 AWG
|
T
|
Extension Wire
|
Solid
|
4
|
Polyvinyl (PVC)
|
Polyvinyl (PVC)
|
None
|
No
|
ANSI (Standard)
|
Multi Pair
|
|
Thermocouple
|
0 to 105°C (32 to 220°F)
|
20 AWG
|
J
|
Extension Wire
|
Solid
|
8
|
Polyvinyl (PVC)
|
Polyvinyl (PVC)
|
None
|
No
|
ANSI (Standard)
|
Multi Pair
|
MI cable with Nickel-Chrome Omegaclad XL sheath, compacted MgO mineral insulation with K or N thermocouple calibrated conductors. Excellent long term drift
Product Number | Category | Thermocouple Type | Process Temperature Range | Sheath Material | Conductor Insulation | Conductor Material | Dual Changed From | Diagonal/Parallel Construction | Cable Diameter | Number of Conductors | Standard/Metric | Special Limit of error | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 800°C (32 to 1472°F)
|
Omegaclad XL
|
MGO
|
Chromel-Alumel
|
No
|
None
|
0.040 in
|
2
|
Standard
|
Yes
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
K
|
0 to 800°C (32 to 1472°F)
|
Omegaclad XL
|
MGO
|
Chromel-Alumel
|
No
|
None
|
0.032 in
|
2
|
Standard
|
No
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Omegaclad XL
|
MGO
|
Chromel-Alumel
|
No
|
None
|
0.062 in
|
2
|
Standard
|
No
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Omegaclad XL
|
MGO
|
Chromel-Alumel
|
No
|
None
|
0.125 in
|
2
|
Standard
|
No
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
K
|
0 to 1204°C (32 to 2200°F)
|
Omegaclad XL
|
MGO
|
Chromel-Alumel
|
No
|
None
|
0.188 in
|
2
|
Standard
|
No
|
Comes with Batch Certtifcation
|
MI cable with stainless steel or Inconel metal sheath, compacted MgO mineral insulation with K, J, T, E, or N thermocouple calibrated conductors.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sheath Material | Conductor Insulation | Conductor Material | Dual Changed From | Diagonal/Parallel Construction | Cable Diameter | Number of Conductors | Standard/Metric | Special Limit of error | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 300°C (32 to 570°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
0.010 in
|
2
|
Standard
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 300°C (32 to 570°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
0.020 in
|
2
|
Standard
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 300°C (32 to 570°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
0.032 in
|
2
|
Standard
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 300°C (32 to 570°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
0.040 in
|
2
|
Standard
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
0.062 in
|
2
|
Standard
|
No
|
None
|
MI Cable with stainless steel or Inconel metal sheath, compacted MgO mineral insulation with 2, 3, or 4 Nickel 201 conductors.For RTD and Thermistor.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sheath Material | Conductor Insulation | Conductor Material | Dual Changed From | Diagonal/Parallel Construction | Cable Diameter | Number of Conductors | Standard/Metric | Special Limit of error | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
None
|
-200 to 482°C (-328 to 900°F)
|
304 Stainless Steel
|
MGO
|
Nickel
|
No
|
None
|
0.062 in
|
3
|
Standard
|
No
|
Comes with Batch Certtifcation
|
|
RTD
|
None
|
-200 to 482°C (-328 to 900°F)
|
304 Stainless Steel
|
MGO
|
Nickel
|
No
|
None
|
0.062 in
|
3
|
Standard
|
No
|
None
|
|
RTD
|
None
|
-200 to 482°C (-328 to 900°F)
|
304 Stainless Steel
|
MGO
|
Nickel
|
No
|
None
|
0.125 in
|
3
|
Standard
|
No
|
None
|
|
RTD
|
None
|
-200 to 482°C (-328 to 900°F)
|
304 Stainless Steel
|
MGO
|
Nickel
|
No
|
None
|
0.250 in
|
3
|
Standard
|
No
|
None
|
|
RTD
|
None
|
-200 to 482°C (-328 to 900°F)
|
304 Stainless Steel
|
MGO
|
Nickel
|
No
|
None
|
0.040 in
|
4
|
Standard
|
No
|
None
|
MI cable with stainless steel or Inconel metal sheath, compacted MgO mineral insulation with dual K, J, T, E, or N thermocouple calibrated conductors.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sheath Material | Conductor Insulation | Conductor Material | Dual Changed From | Diagonal/Parallel Construction | Cable Diameter | Number of Conductors | Standard/Metric | Special Limit of error | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 730°C (32 to 1350°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
0.188 in
|
4
|
Standard
|
No
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
E
|
0 to 820°C (32 to 1510°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
0.250 in
|
4
|
Standard
|
No
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
0.062 in
|
4
|
Standard
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 650°C (32 to 1200°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
0.125 in
|
4
|
Standard
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 730°C (32 to 1350°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
0.188 in
|
4
|
Standard
|
No
|
None
|
MI cable with stainless steel or Inconel metric sized metal sheath, compacted MgO mineral insulation with K, J, T, E, or N thermocouple calibrated conductors.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sheath Material | Conductor Insulation | Conductor Material | Dual Changed From | Diagonal/Parallel Construction | Cable Diameter | Number of Conductors | Standard/Metric | Special Limit of error | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 650°C (32 to 1200°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
3.0 mm
|
2
|
Metric
|
No
|
Comes with Batch Certtifcation
|
|
Thermocouple
|
E
|
0 to 300°C (32 to 570°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
0.50 mm
|
2
|
Metric
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 300°C (32 to 570°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
1.00 mm
|
2
|
Metric
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
1.5 mm
|
2
|
Metric
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
No
|
None
|
2.0 mm
|
2
|
Metric
|
No
|
None
|
MI cable with stainless steel or Inconel metric sized metal sheath, compacted MgO mineral insulation with dual K, J, T, E, or N thermocouple calibrated conductors.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sheath Material | Conductor Insulation | Conductor Material | Dual Changed From | Diagonal/Parallel Construction | Cable Diameter | Number of Conductors | Standard/Metric | Special Limit of error | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
1.5 mm
|
4
|
Metric
|
No
|
None
|
|
Thermocouple
|
E
|
0 to 820°C (32 to 1510°F)
|
304 Stainless Steel
|
MGO
|
Chromel-Constantan
|
Yes
|
Parallel (US)
|
6.0 mm
|
4
|
Metric
|
No
|
None
|
|
Thermocouple
|
J
|
0 to 440°C (32 to 825°F)
|
304 Stainless Steel
|
MGO
|
Iron-Constantan
|
Yes
|
Parallel (US)
|
1.5 mm
|
4
|
Metric
|
No
|
None
|
|
Thermocouple
|
J
|
0 to 520°C (32 to 970°F)
|
304 Stainless Steel
|
MGO
|
Iron-Constantan
|
Yes
|
Parallel (US)
|
3.0 mm
|
4
|
Metric
|
No
|
None
|
|
Thermocouple
|
J
|
0 to 720°C (32 to 1300°F)
|
304 Stainless Steel
|
MGO
|
Iron-Constantan
|
Yes
|
Parallel (US)
|
6.0 mm
|
4
|
Metric
|
No
|
None
|