text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Please validate your credit card and billing information.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please validate your credit card and billing information.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

High accuracy Multi-Function Calibrator

Item# PCL1000

High accuracy Multi-Function Calibrator PCL1000 PCL1000
  • Excellent Accuracy ±0.6°C T/C, ±0.3°C RTD 0.015% Electrical 0.05% Pressure
  • Read and Source Modes
  • 10 T/C Types; 8 RTD types plus 400 Series Thermistor
  • Stores up to 9 setpoints for each output function
  • Measures pressure using external modules
Display Type
Input Type
Features
Quantity Price each
1-4 $1,620.00
5-9 $1,539.00
10-24 $1,506.60
25-49 $1,441.80
50-99 $1,409.40
100+ $1,377.00

In stock

Lead Time ( If not in Stock): 12 weeks

Product Specs

  • Battery Life 25 hrs
  • Batteries Included Yes
  • Battery Size AA
  • Battery Type Alkaline
  • Power Source Battery
  • Rechargeable Battery No
  • Number of Batteries 4
  • Stability 0.01% F.S./°C outside of 23°C±5°C

SPECIFICATIONS
Operational Temp Range:
0 to 50°C (14 to 122°F)
Stability:0.01% F.S./°C outside of 23°C±5°C
Pressure Accuracy: 0.05% FS
Max Overpressure: 300%
Ports:<100 psi 1/4" barbed hose fittings,≤ 100 psi: 1/8" brass swagelok fittings
Wetted Parts: clean dry gases only
T/C Types: J,K,T,E,R,S,B,N,L,U
RTD Ranges: RTD Ranges: Pt385 (100, 200, 500, 1000Ω) Pt392, JIS, Ni120, CU10, YS1400
Ohm Ranges: 0 to 400.00 and 400.0 to 4000.0
Voltage:
(Low) I/O 0-20.000 V
(High) Input only 0-250 V ac/dc
Frequency: 0-1000.0 CPS, Hz 0-10.00 kHz
Continuity: 0 to 400.0Ω audible tone under 10Ω
Accuracy: T/C Type J: ±0.3°C ± 10µV (±0.6°C total error)
RTD Pt100: ±0.1°C ±0.075 Ω (±0.3°C total error)
Ohms (400): ±0.1 Ω
Ohms (4000): ±1.0 Ω
mA Compliance: up to 1000 Ω
Voltage Drive: 1 mA
RTD IEX-range: 0.01 mA to 3 mA
RTD Frequency Response: 10 mS
Operating Temp: -10 to 50°C
Storage Temp: -40 to 60°C
Power: 4 AA alkaline batteries (included)
Dimensions: 191x102x38 mm(7.5x4x1.5")
Weight: 350g (12oz)

External Pressure Modules*
MODEL NO.Parameter Range Gauge (psig)AccuracyOver Pressure
PCL-PMAPressure Module adaptor (one required)
PCL-PM030G0 to 30 (0 to 2 bar)±0.025%300%
PCL-PM050G0 to 50 (0 to 3.5 bar)±0.03%300%
PCL-PM100G0 to 100 (0 to 7 bar)±0.025%300%
PCL-PM300G0 to 300 (0 to 20 bar)±0.025%200%
PCL-PM1KG0 to 1000 (0 to 70 bar)±0.05%200%
PCL-PM3KG0 to 3000 (0 to 200 bar)±0.1%200%
PCL-PM5KG0 to 5000 (0 to 340 bar)±0.1%200%
PCL-PM015VAC0 to -15 (0 to -1 mbar)±0.025%, ±0.0025 psi300%
PCL-PM015A0 to 15 (0 to 1 bar) abs.±0.025%, ±0.0025 psi300%
PCL-PM030A0 to 30 (0 to 2 bar) abs.±0.025%300%
PCL-PM015C-15 to 15 (-1 to 1 bar)±0.025%, ±0.0025 psi300%
PCL-PM030C-15 to 30 (-1 to 2 bar)±0.025%, ±0.0025 psi300%
PCL-PM030D0 to 30 (0 to 2 bar) diff.±0.025%300%
* Most popluar ranges (see pressure module page for all ranges).