text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Portable Pressure Calibrators with Internal Pressure Source

Item# PCL-5000A

Portable Pressure Calibrators with Internal Pressure Source Portable Pressure Calibrators with Internal Pressure Source
For rapid on-site calibration of transducers, transmitters, gages, and many other pressure-sensitive devices, OMEGA ® PCL-5000 Series calibrators provide high accuracy, reliability, and automatic pushbutton operation. OMEGA’s PCL-5000 portable, precision pressure calibrator is designed for the higher pressure range calibrations (20 to 2000 psi) and has its own self-contained 2000 psi nitrogen cylinder. It also provides push-button operation and switch selectable calibration modes for absolute or gagepressure. An extremely accurate instrument (±0.05% FS), the PCL-5000 comes complete with quick disconnect fittings and hoses for input and output pressure. The PCL-5100, a low-pressure unit with ranges from 30 inHG to 100 psi, offers five independent selectable ranges. Specifically designed for rugged field usage, it weighs less than 25 pounds and has its own built-in pressure and vacuum source.
PCL-5000A
  • 0.05% FS Accuracy
  • Dual Scale Gage and Absolute Pressure Ranges
  • Portable, Lightweight, Approx. 11 kg (24 lb)
  • NIST Certificate Provided
  • All Hoses, Fittings, Connectors Supplied
  • Voltage/Current Display Mode for Transducer Testing
  • Over-Pressure Protection
Pressure Ranges
Accuracy Value
Pressure Type
Features
Function
See All Options
Quantity Price each
1-4 $9,750.00
5-9 $9,262.50
10-24 $9,067.50
25-49 $8,677.50
50-99 $8,482.50
100+ $8,287.50

In stock

Lead Time ( If not in Stock): 7 weeks

Product Specs

  • Accuracy Value ±0.05% FS Max. (Accuracy statement includes all effects of linearity
  • Fill and Test Port Rating 3000 psig
  • Fill and Test Port Type Quick Disconnect
  • Filter Rating 7 microns
  • Internal Pressure Cylinder Rating 2015 psi
  • Internal Pressure Cylinder Volume 80 cubic inches
  • Maximum Connection Rating Style quick disconnect type
  • Internal Volume 80 cubic inches
  • Maximum Ambient Temperature 43 {C} (110 {F})
  • Overpressure Rating 3000 psig
  • Overpressure Rupture Disk Rating 3000 psig
  • Power Source 117 or 220 Vac ±10%
  • Pressure Connection Style quick disconnect type
  • Pressure Media Filter Rating 3000 psig

For rapid on-site calibration of transducers, transmitters, gages, and many other pressure-sensitive devices, OMEGA ® PCL-5000 Series calibrators provide high accuracy, reliability, and automatic pushbutton operation. OMEGA’s PCL-5000 portable, precision pressure calibrator is designed for the higher pressure range calibrations (20 to 2000 psi) and has its own self-contained 2000 psi nitrogen cylinder. It also provides push-button operation and switch selectable calibration modes for absolute or gagepressure. An extremely accurate instrument (±0.05% FS), the PCL-5000 comes complete with quick disconnect fittings and hoses for input and output pressure. The PCL-5100, a low-pressure unit with ranges from 30 inHG to 100 psi, offers five independent selectable ranges. Specifically designed for rugged field usage, it weighs less than 25 pounds and has its own built-in pressure and vacuum source.