text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Ethernet to Serial Device Server

Item# OM-ES-020

Ethernet to Serial Device Server Ethernet to Serial Device Server
The OM-ES-020 ethernet to serial device server is ideal for industrial applications. Data transfer rates up to 1,000,000 baud, coupled with 1Mbit/s line drivers deliver uncompromising performance. The OM-ES-020 range provides simple instant networked serial ports. A web interface allows secure configuration and control of the serial ports over a local network or the internet using any browser.

For Windows® our 32- and 64-bit driver gives you local COM ports, retaining existing software applications and allowing you to connect across your network to remote devices just as if they were attached locally. You can access the device via TCP/IP sockets from any networked device like an Android tablet, PC or phone. Serial port tunneling (individually configurable) allows serial cable replacement over any distance, no software required. On Windows OS TCP/IP sockets are handled by the Winsock API, this will differ on other OSs. The OM-ES-020 can be wired into existing power and network infrastructure or it can be used with a separate power supply.

Windows Users Our software drivers give you local COM ports, allowing you to retain your existing software applications and connect to your devices over the network. COM Port can be assigned from COM1 to COM255 and the OM-ES-020 ethernet to serial device remembers your COM Port assignment on reboots.

Web Interface Users (Linux/Apple OS/Android)
Alternatively access the device via TCP/IP socket from any networked device. Configure options via web interface.
OM-ES-020
  • 1 Port RS232 to Ethernet Device Server
  • Maximum Baud Rate 1,000,000 (1 MegaBaud)
  • 10/100Base TX Ethernet Port
  • User Friendly Interface
  • Web Configuration and RFC2217 Compliant Interface for Non-Windows Users
  • NEMA 1 (IP-30) Rated Enclosure
  • LED Status Indication
  • Serial Port Tunneling (Individually Configurable) Allows Serial Cable Replacement Over Any Distance, No Software Required
Communications Protocols
Data Rate
Quantity Price each
1-9 $249.00
10-24 $236.55
25-49 $231.57
50-99 $221.61
100-199 $216.63
200+ $211.65

In stock

Lead Time ( If not in Stock): 8 weeks

Product Specs

  • Connectivity Method 1 port RS232

The OM-ES-020 ethernet to serial device server is ideal for industrial applications. Data transfer rates up to 1,000,000 baud, coupled with 1Mbit/s line drivers deliver uncompromising performance. The OM-ES-020 range provides simple instant networked serial ports. A web interface allows secure configuration and control of the serial ports over a local network or the internet using any browser.

For Windows® our 32- and 64-bit driver gives you local COM ports, retaining existing software applications and allowing you to connect across your network to remote devices just as if they were attached locally. You can access the device via TCP/IP sockets from any networked device like an Android tablet, PC or phone. Serial port tunneling (individually configurable) allows serial cable replacement over any distance, no software required. On Windows OS TCP/IP sockets are handled by the Winsock API, this will differ on other OSs. The OM-ES-020 can be wired into existing power and network infrastructure or it can be used with a separate power supply.

Windows Users Our software drivers give you local COM ports, allowing you to retain your existing software applications and connect to your devices over the network. COM Port can be assigned from COM1 to COM255 and the OM-ES-020 ethernet to serial device remembers your COM Port assignment on reboots.

Web Interface Users (Linux/Apple OS/Android)
Alternatively access the device via TCP/IP socket from any networked device. Configure options via web interface.

  • CE Icon CE

en-US
en
Save Configuration