text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Submersible Flat Surface pH/ORP Electrodes

Item# ORE-6510-ACRYL-GL

Submersible Flat Surface pH/ORP Electrodes
The OMEGA™ PHE/ORE-6510 Series submersible electrodes are designed for use in drums, open tanks and streams, etc. The flat sensing surface is surrounded by a porous polyethylene reference junction which minimizes fouling. Electrode installation and removal done by a simple 1/4 turn quick disconnect. The cable assembly's cap has 1/2" MNPT thread, which can be connected to a coupling and support pipe. The pipe allows easy mechanical mounting and protects the cable from the liquid measured. The resulting assembly is lightweight for convenient handling when maintenance is needed. ATC is available as part of the mounting assembly.

The flat surface design is well suited for applications with relatively high suspended solids or where flocculation operations require low velocities.

Where only low velocities are present and coating is a problem, the electrode can be mounted at a 45° angle facing the flow so as to obtain increased scrubbing action across the measuring surface.
ORE-6510-ACRYL-GL
  • CPVC or PVDF Construction
  • Designed For Mounting in Tanks, Flumes, etc
  • Easy Mounting in Tanks
Electrode Material
Connection Type
Length
Maximum Temperature Measurement
Connection Size
RTD type
Electrical Connection
Features
See All Options
Quantity Price each
1-9 $475.00
10-24 $451.25
25-49 $441.75
50-99 $422.75
100-199 $413.25
200+ $403.75

In stock

Lead Time ( If not in Stock): 6 weeks

Product Specs

The OMEGA™ PHE/ORE-6510 Series submersible electrodes are designed for use in drums, open tanks and streams, etc. The flat sensing surface is surrounded by a porous polyethylene reference junction which minimizes fouling. Electrode installation and removal done by a simple 1/4 turn quick disconnect. The cable assembly's cap has 1/2" MNPT thread, which can be connected to a coupling and support pipe. The pipe allows easy mechanical mounting and protects the cable from the liquid measured. The resulting assembly is lightweight for convenient handling when maintenance is needed. ATC is available as part of the mounting assembly.

The flat surface design is well suited for applications with relatively high suspended solids or where flocculation operations require low velocities.

Where only low velocities are present and coating is a problem, the electrode can be mounted at a 45° angle facing the flow so as to obtain increased scrubbing action across the measuring surface.

en-US
en
Save Configuration