text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Isolated Transmitters mA input, Isolated Vdc Output or Vdc input with Isolated mA Output

Item# PXTX-4900-Series

Isolated Transmitters mA input, Isolated Vdc Output or Vdc input with Isolated mA Output Isolated Transmitters mA input, Isolated Vdc Output or Vdc input with Isolated mA Output
The OMEGA™ PXTX-4900 and PXTX-4901 transmitters isolate a 4-20 mA current loop from the 0 to +10 Vdc signal and the power line. These units are ideal for eliminating ground loops and common mode signals. In the PXTX-4901, which converts 4-20 mA to 0 to 10 Vdc, the input resistance is less than 50 Ohms, generating less than 1 Volt drop at 20 mA loop current. The PXTX-4900 converts a 0 to 10 Vdc to a 4-20 mA output signal. For both models, the 400 Hz frequency response provides a settling time of less than 0.003 seconds to 0.1%, which prevents signal degradation. Both models are completely encapsu-lated for use in rugged environments. They are similarly protected against shock and vibration for years of reliable and accurate operation. All connections are easily made to conveniently located barrier strips.
PXTX-4900-Series
  • Voltage Input with Current Output or Current Input with Voltage Output
  • 1500 Volts RMS of CMV Isolation
  • Factory Calibrated for Accuracy of ±0.1%
  • Operates from 115 Vac 50/60 Hz or 230 Vac
  • Rugged Epoxy Encapsulated Design

In stock

Lead Time ( If not in Stock): 0 week

Product Specs

  • Accuracy Value ±0.1% of span maximum
  • Maximum Ambient Temperature 85 {C} (185 {F})
  • Minimum Ambient Temperature -20 {C} (-4 {F})
  • Maximum Storage Temperature 85 {C} (185 {F})
  • Minimum Storage Temperature -20 {C} (-4{F})
  • Supply Frequency 50/60 Hz
  • Accuracy Value ±0.1% of span maximum
  • Maximum Storage Temperature 85 {C} (185 {F})
  • Maximum Ambient Temperature 85 {C} (185 {F})
  • Minimum Ambient Temperature -20 {C} (-4 {F})
  • Minimum Storage Temperature -20 {C} (-4{F})
  • Supply Frequency 50/60 Hz

The OMEGA™ PXTX-4900 and PXTX-4901 transmitters isolate a 4-20 mA current loop from the 0 to +10 Vdc signal and the power line. These units are ideal for eliminating ground loops and common mode signals. In the PXTX-4901, which converts 4-20 mA to 0 to 10 Vdc, the input resistance is less than 50 Ohms, generating less than 1 Volt drop at 20 mA loop current. The PXTX-4900 converts a 0 to 10 Vdc to a 4-20 mA output signal. For both models, the 400 Hz frequency response provides a settling time of less than 0.003 seconds to 0.1%, which prevents signal degradation. Both models are completely encapsu-lated for use in rugged environments. They are similarly protected against shock and vibration for years of reliable and accurate operation. All connections are easily made to conveniently located barrier strips.