text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Field Rangeable Miniature 2-Wire Transmitters, Isolated Models Available

Item# NB1TX901-K

Field Rangeable Miniature 2-Wire Transmitters, Isolated Models Available Field Rangeable Miniature 2-Wire Transmitters, Isolated Models Available
TX900 Series transmitters feature dip switch selection of input type and range. The following models are available: TX901 (non-isolated, accepts J, K,T, E, R or S thermocouples) TX903 (isolated, accepts J, K, T, E, R or S thermocouples TX904 (non-isolated, accepts 100 ohm Pt RTD’s 2- or 3- wire) TX905 (non-isolated, millivolt input).

For complete product specifications see the Related Links section at the bottom of this page.
NB1TX901-K
  • Thermocouple, RTD and Millivolt Input Models
  • Compact Size, Only 3/4" High (Non-Isolated) and 1.15" High (Isolated) Including Barrier Strip
  • 4-20 mA Output
  • ±0.1% FS Accuracy
  • TX903 Isolated Model (Other Models Non-Isolated)
  • Mounts in Protection Head
Input Ranges
Input Type
Number of Inputs
Output Type
Quantity Price each
1-9 $311.71
10-24 $296.12
25-49 $289.89
50-99 $277.42
100-199 $271.19
200+ $264.95

In stock

Lead Time ( If not in Stock): 2 weeks

Product Specs

  • Accuracy Value ±0.1% FS (includes effects of linearity
  • Form Factor Protection Head
  • Maximum Ambient Temperature 85 {C} (185 {F})
  • Minimum Ambient Temperature -25 {C} (-13 {F})
  • Maximum Storage Temperature 125{C} (257{F})
  • Minimum Storage Temperature -65 {C} (-85 {F})
  • RTD Curves Supported a = 0.00385
  • Supply Frequency 3 dB @ 3 Hz
  • Form Factor Protection Head
  • Accuracy Value ±0.1% FS (includes effects of linearity
  • Maximum Storage Temperature 125{C} (257{F})
  • Maximum Ambient Temperature 85 {C} (185 {F})
  • Minimum Ambient Temperature -25 {C} (-13 {F})
  • Minimum Storage Temperature -65 {C} (-85 {F})
  • Supply Frequency 3 dB @ 3 Hz
  • RTD Curves Supported a = 0.00385

TX900 Series transmitters feature dip switch selection of input type and range. The following models are available: TX901 (non-isolated, accepts J, K,T, E, R or S thermocouples) TX903 (isolated, accepts J, K, T, E, R or S thermocouples TX904 (non-isolated, accepts 100 ohm Pt RTD’s 2- or 3- wire) TX905 (non-isolated, millivolt input).

For complete product specifications see the Related Links section at the bottom of this page.