text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

ALARM MODULE - DC INPUT TO SINGLE ALARM

Item# DMD1080

ALARM MODULE - DC INPUT TO SINGLE ALARM ALARM MODULE - DC INPUT TO SINGLE ALARM
The DMD1080 accepts a DC voltage or current input and provides visual alarm indication and alarm relay contact outputs. 15 voltage and 9 current input ranges can be field configured via external rotary and slide switches. Offset ranges such as 1 to 5 Vdc and 4 to 20 mAdc are also included. Heavy-duty relay contacts allow the module to directly control high capacity loads. Front accessible potentiometers are used to adjust the alarm setpoint from 0 to 100% and the deadband from 1 to 100%. The unit provides a single setpoint adjustment of the two DPST relay contacts. The alarm output can be field configured for HI or LO operation, latching or non-latching, and normal or reverse acting.
DMD1080
  • Easy Field Setup --- One Minute Setup for 24 Input Ranges
  • Switch Selectable Relay Configuration
  • Removable Plugs for Faster Installation
  • Input Tracker and Alarms Status LEDs
  • Full 1200V Isolation
  • Alarm Test/Reset Button
  • Built-In Loop Power Supply for Sink/Source Input
Relay Type
Number of Relay Outputs
Input Type
Supply Voltage
 This item is available for quick shipping
Quantity Price each
1-4 $265.00
5-9 $251.75
10-24 $246.45
25-49 $235.85
50-99 $230.55
100+ $225.25

In stock

Lead Time ( If not in Stock): 5 weeks

Product Specs

  • Current Input Ranges 0-1 mADC to 0-20 mADC
  • Maximum Ambient Temperature 60°C (140°F)
  • Minimum Ambient Temperature -10°C (14°F)
  • Voltage Input Ranges Voltage: 0-50 mV to 0-10 Vdc Bipolar Voltage: ±5 Vdc or ±10 Vdc
  • Response Time 70 milliseconds typical

The DMD1080 accepts a DC voltage or current input and provides visual alarm indication and alarm relay contact outputs. 15 voltage and 9 current input ranges can be field configured via external rotary and slide switches. Offset ranges such as 1 to 5 Vdc and 4 to 20 mAdc are also included. Heavy-duty relay contacts allow the module to directly control high capacity loads. Front accessible potentiometers are used to adjust the alarm setpoint from 0 to 100% and the deadband from 1 to 100%. The unit provides a single setpoint adjustment of the two DPST relay contacts. The alarm output can be field configured for HI or LO operation, latching or non-latching, and normal or reverse acting.