text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Conductivity, Resistivity or TDS Controller

Item# CDCN-961

Conductivity, Resistivity or TDS Controller Conductivity, Resistivity or TDS Controller
The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for inline monitoring of process solutions and water applications.

The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.
CDCN-961
  • Monitors conductivity, resistivity and TDS in process solutions and water applications.
  • Menu-Driven Programming
  • NEMA 4X (IP65) Protection
  • Programmable High/Low, and Alarm Relays
  • Dual Backlit LCD
  • Calibration Reminder Via Alarm Relay Setting
  • Isolated 0.4 to 20 mA Output
  • RS485 Output
  • Applications
  • Waste Water Treatment
  • Power Plants
  • Thermo-Electric Plants
  • Pharmaceutical
  • Photographic Industries
  • Soft Drink Industries
Range
Supply Voltage
Number of Control Outputs
Control Output Type
Form Factor
Number of Display Digits
Cell Constants

$1,220.00

In stock

Lead Time ( If not in Stock): 12 weeks

Product Specs

  • Accuracy Value ±1% FS
  • Cell Material PPS/graphite
  • Cell Range 0.000 to 3.000
  • Communication Output Types 0/4 to 20 mA/600Ω
  • Communications Protocol RS485 Output
  • Maximum Ambient Humidity 95%
  • Maximum Ambient Temperature 50 {C} (122 {F})
  • Maximum Conductivity 0.000 to 3.000
  • Maximum Resistance 0.3 to 30.0 MΩcm
  • Measurement Type Conductivity
  • Measurement Units µS/cm
  • Minimum Ambient Humidity 10%
  • Minimum Ambient Temperature -10 {C} (14 {F}
  • Panel Cutout Size 93.5 L x 93.5 W mm (3.68 x 3.68")
  • Minimum Conductivity 0
  • Resolution 0.001/0.01/0.1 1/4S/cm
  • TDS Operating Range 0.000 to 3.000
  • Resistivity Range 0.3 to 30.0 MΩcm
  • Temperature Sensor Type PT1000

The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for inline monitoring of process solutions and water applications.

The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.

  • CE Icon CE