text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Conductivity or Resistivity Controller

Item# CDCN441

Conductivity or Resistivity Controller Conductivity or Resistivity Controller
The CDCN441 conductance/resistance analyzercontroller is designed for online monitoring of process solutions and water applications. Applications include: waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries and soft drinks industries. The menus are self guiding with simple three button programming. Available control outputs include ON-OFF or pulse width modulation. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the cell used and the buffer solution resulting in a simple and straight forward system calibration.

Equipment is built with solid state technology, electronic contacts and not electrical contacts, avoiding mechanical movement and off course no sparks.
CDCN441
  • Analyzer/Transmitter/Controller
  • Self-Guided Menu
  • Auto-Range Scales
  • Automatic Calibration and Check
  • Recognizes Standard and Cell
  • Automatic Temperature Compensation
  • On-Off/PWM Control
  • Programmable Transmitter Output
  • RS485 Output
Range
Supply Voltage
Number of Control Outputs
Control Output Type
Form Factor
Number of Display Digits
See All Options
Quantity Price each
1-4 $999.60
5-9 $949.62
10-24 $929.63
25-49 $889.64
50-99 $869.65
100+ $849.66

In stock

Lead Time ( If not in Stock): 8 weeks

Product Specs

  • Cell Connection Type 316 SS
  • Cell Material Aluminum (SAE323)
  • Cell Insertion Length 42 mm (1.7")
  • Communication Output Types 2 N.O. (1A/240 Vac) on/off alarm or PWM 4 to 20 mA for PID control or retransmission
  • Maximum Ambient Temperature 40 {C} (104 {F})
  • Maximum Conductivity 1µS/cm to 2S/cm2S/cm
  • Maximum Resistance infinity
  • Measurement Units µS
  • Minimum Ambient Temperature 5 {C} (41 {F})
  • Minimum Conductivity 1µS/cm
  • Minimum Resistance 10 MΩ/cm
  • Reading Modes Continuous
  • Resolution 0.1 or 0.01
  • Resistivity Range 10 MΩ/cm to infinity
  • Temperature Compensation 0 to 100°C (32 to 212°F)

The CDCN441 conductance/resistance analyzercontroller is designed for online monitoring of process solutions and water applications. Applications include: waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries and soft drinks industries. The menus are self guiding with simple three button programming. Available control outputs include ON-OFF or pulse width modulation. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the cell used and the buffer solution resulting in a simple and straight forward system calibration.

Equipment is built with solid state technology, electronic contacts and not electrical contacts, avoiding mechanical movement and off course no sparks.

  • CE Icon CE