text.skipToContent text.skipToNavigation

Alert: We are currently experiencing problems registering new customers, live chat, and resetting passwords. Please try again later.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Toroidal Conductivity or Concentration Analyzer

Item# CDCN442

Toroidal Conductivity or Concentration Analyzer Toroidal Conductivity or Concentration Analyzer
The CDCN442 toroidal conductivity system isdesigned for online monitoring of chemically aggressive process solutions, water applications that coat or foul traditional sensors, and plating bath operations in which high current densities are present. The sensor consists of 2 metallic ribbon coils that are fixed in place by the sensor jacket material. The drive coil is used to induce a current in the process solution. The second sensing coil is used to measure the current in the process solution the magnitude of this current is proportional to the conductivity of the process solution. Toroidal sensors are available in polypropylene, and PEEK™ to ensure that sensor-wetted materials are chemically resistant to process chemicals. The sensor material is nonconductive, thereby isolating the sensor from electrical noise and ground loops that can influence the integrity of the measurement. This material also makes the sensor resistant to electrode coating, since most substances do not adhere to the sensor material. Sensors can be submersion mounted for easy installation in open tanks or pipe mounted in the optional 51 mm (2") tee fitting, which is keyed to the sensor for proper alignment. Tee fitting material is polypropylene. For larger pipe diameters, the sensor can be insertion mounted through a 11.2 NPT ball valve for easy retraction. The monitor comes with concentration/temperature tables for sodium hydroxide, potassium hydroxide, hydrochloric acid, nitric acid, and sulfuric acid. A configurable table allows the user to enter data points for a custom concentration curve. Typical applications include waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries, soft drinks industries.
CDCN442
  • NEMA 4X (IP68) Case
  • 2 x 16 Digit LCD Readout
  • Assembly in 51 mm (2") Tube or Flat Surface or Panel 144 x 144 x 100 mm DIN (5.7 x 5.7 x 4")
  • Simple 3 Key Operation
  • Offers Cell Check
  • RS485 Output, ModBus and Proprietary Communication Protocol
Range
Supply Voltage
Number of Control Outputs
Control Output Type
Form Factor
Number of Display Digits
Cell Constants
See All Options
Quantity Price each
1-4 $989.80
5-9 $940.31
10-24 $920.51
25-49 $880.92
50-99 $861.13
100+ $841.33

In stock

Lead Time ( If not in Stock): 8 weeks

Product Specs

  • Cell Insertion Length 100 mm (3.93")
  • Cell Range 1 µS/cm to 1 S/cm
  • Communication Output Types 4 to 20 mA (2)
  • Maximum Ambient Temperature 40 {C} (104 {F})
  • Maximum Conductivity 1 S/cm
  • Maximum Loop Impedance 600 Ω
  • Maximum Resistance infinity
  • Minimum Ambient Temperature 5 {C} (41 {F})
  • Minimum Conductivity 1µS/cm
  • Minimum Resistance 10 MΩ/cm
  • Power 3.5 VA
  • Resolution 0.1 or 0.01
  • Resistivity Range 10 MΩ/cm to infinity
  • Temperature Compensation 0 to 100°C (32 to 212°F)

The CDCN442 toroidal conductivity system isdesigned for online monitoring of chemically aggressive process solutions, water applications that coat or foul traditional sensors, and plating bath operations in which high current densities are present. The sensor consists of 2 metallic ribbon coils that are fixed in place by the sensor jacket material. The drive coil is used to induce a current in the process solution. The second sensing coil is used to measure the current in the process solution the magnitude of this current is proportional to the conductivity of the process solution. Toroidal sensors are available in polypropylene, and PEEK™ to ensure that sensor-wetted materials are chemically resistant to process chemicals. The sensor material is nonconductive, thereby isolating the sensor from electrical noise and ground loops that can influence the integrity of the measurement. This material also makes the sensor resistant to electrode coating, since most substances do not adhere to the sensor material. Sensors can be submersion mounted for easy installation in open tanks or pipe mounted in the optional 51 mm (2") tee fitting, which is keyed to the sensor for proper alignment. Tee fitting material is polypropylene. For larger pipe diameters, the sensor can be insertion mounted through a 11.2 NPT ball valve for easy retraction. The monitor comes with concentration/temperature tables for sodium hydroxide, potassium hydroxide, hydrochloric acid, nitric acid, and sulfuric acid. A configurable table allows the user to enter data points for a custom concentration curve. Typical applications include waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries, soft drinks industries.