text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Universal Temperature/Process Controllers

Item# CN8541MA-DC1

Universal Temperature/Process Controllers Universal Temperature/Process Controllers

The CN8500 Series temperature controller is versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application. A dual digital display offers optimal process information at a glance. The dedicated upper display shows the process temperature, while the lower display displays setpoint and setup parameters. Individual LEDs identify the status outputs, alarms, digital communications, and special options. The CN8500 Series features a NEMA 4X front panel and a universal power supply that accepts 103 to 253 Vac and 103 to 330 Vdc. Control algorithms available are P, PI, PD, PID, and on/off. The autotune feature automatically sets proportional band, rate, and reset before the process reaches setpoint. These parameters provide quick stabilization of both the heating and cooling process without overshoot, hunting, or cycling. The standard dual control outputs can be configured in a variety of control and alarm applications such as heat, heat/cool, heat/alarm, cool, or cool/alarm. The ramp-to-setpoint feature allows the user to define the rate of rise to reach the setpoint, thus minimizing thermal shock to the load during start-up. 

SPECIFICATIONS

Input CodeTypeRangeResolution
TCJ
Iron-constantan
-18 to 760°C1°C
0 to 1400°F1°F
K
CHROMEGA™-ALOMEGA
-18 to 1349°C1°C
0 to 2460°F1°F
T
Copper-constantan
-129 to 316°C1°C
-200 to 600°F1°F
N
OMEGALLOY™
-18 to 1299°C1°C
0 to 2370°F1°F
R
Pt/13% Rh-Pt
-18 to 1299°C1°C
0 to 3200°F1°F
S
Pt/10% Rh-Pt
-18 to 1299°C1°C
0 to 3200°F1°F
RTDRTD
3-wire, 100 Ω Pt
-200 to 850°C1°C
-328 to 1562°F1°F
RTD
3-wire, 100 Ω Pt
-128.8 to 232.2°C0.1°C
-199.0 to 450.0°F0.1°F
V51 to 5 VScalable (-1999 to 9999)Selectable
0 to 5 V
V102 to 10 VScalable (-1999 to 9999)Selectable
0 to 10 V
MV10 to 50 mVScalable (-1999 to 9999)Selectable
0 to 50 mV
MA4 to 29 mAScalable (-1999 to 9999)Selectable
0 to 20 mA


Performance 
Accuracy: ±0.2% FS, ±1 digit 
Setpoint Resolution: 1 count/0.1 count 
Repeatability: ±1.0 count 
Temperature Stability: 5 µV/°C max; 3 ìV/°C typical 
Thermocouple Cold-Junction Tracking: 0.05°C/°C ambient 
Common Mode Rejection: >100 dBA 
Series Mode Rejection: >70 dBA 
Process Sampling: 10 Hz (100 ms) 

Inputs 
Thermocouple Lead Resistance: 100 Ω max for rated accuracy 
Response Time: 0.1, 1.0 or 10 s 
Decimal Position: Selectable 

Outputs 
Output #1: Reverse acting (heating) 
Output #2: Direct acting (cooling) 
Mechanical Relay: Rated 5 A @ 120 Vac, 3 A @ 240 Vac 
Current: 4 to 20 mA, 500 Ω max 
Voltage: 20 Vdc pulse, 1 kΩ min load 
Triac: Solid state relay, 120/240 Vac, zero voltage switched rated 1 A continuous, 10 A surge @ 25°C (77°F) 
Alarms: Optically isolated triac rated 1 A, 120/240 Vac @ 25°C (77°F) 

Control Characteristics 
Setpoint Limits: Limited to configured range for thermocouple and RTD; limited to scaled range 
Alarms: Adjustable for high/low, process or deviation 
Rate: 0 to 900 s 
Reset: 0 to 3600 s 
Cycle Time: 0.2 to 120 s 
Gain: 0 to 400 
Gain Ratio: 0 to 2.0 (in 0.1 increments) 
On/Off Deadband: 1 to 100 counts 
Spread (Output 2): 0 to 100 counts (above setpoint) 
Damping: Adjustable (low, normal or high) 
Ramp to Setpoint: 1 to 100 minutes 
Autotune: Operator-initiated from front panel 
Manual Control: Operator-initiated from front panel 

General 
Power: 115 to 230 Vac ±10%, 50/60 Hz; 115 to 300 Vdc ±10% (auto-polarity) 
Display: Dual LED, 4-digit process display, green menu/parameter display; 9.2 mm (0.37") high for 1/8 DIN models; 14 mm (0.55") process display for 1/4 DIN units 
Power Consumption: Less than 6 VA (instrument) @ 120 Vac 
Weight (1/8 DIN): 0.34 kg (12 oz) 
Weight (1/4 DIN): 0.425 kg (15 oz) 
Panel Cutout (1/8 DIN): 45 x 92 mm (1.772 x 3.622") 
Panel Cutout (1/4 DIN): 92 mm (3.622") square 
Dimensions (1/8 DIN Horizontal): 53 x 100 mm (2.1 x 3.95"); 18.3 mm (0.72") depth 
Dimensions (1/4 DIN): 100 W x 100 H x 18.3 min bezel (3.95 x 3.95 x 0.72") 
Panel Depth: 100 mm (3.937") 
Front-Panel Rating: NEMA 4X (IP66) 
Operating Ambient Range: 0 to 55°C (32 to 131°F) @ 90% RH max, non-condensing 
Memory Protection: Solid state non-volatile memory 
Connections: Rear barrier strip with locking terminals 
Contacts: Twin bifurcated

CN8541MA-DC1
  • NEMA 4X (IP66) Front Panel Standard
  • Universal Power Supply
  • User-Selectable Ramp to Setpoint
  • Smooth Auto/Manual Operation
  • Optional RS232 or RS485 Communications
  • Autotuning Heat or Cool
  • Thermocouple, RTD, Voltage, or Current Input
  • Plug-In Outputs Modules (Field Installable)
  • Dual Outputs and Alarms
  • Optional Heater Break Alarm, Remote Setpoint, Transducer Power Supply, and Recorder Output
Measurement Type
Input Type
Number of Inputs
DIN Size
Display Type
Number of Outputs
Output Type
Max Sampling Rate
Supply Voltage Type
Supply Voltage
Communincations
Accuracy Rating
Other Features
See All Options
Quantity Price each
1-9 $383.25
10-24 $364.09
25-49 $344.93
50-99 $325.76
100-499 $306.60
500+ $287.44

In stock

Lead Time ( If not in Stock): 4 weeks

Product Specs

  • Analog Voltage Input Ranges 1 to 5 V
    1 to 5 V
  • Communication Protocols (Sku Variant) RS232 or RS485
    RS232 or RS485
  • Analog Current Input Ranges 0 to 20 mA or 4 to 20 mA
    0 to 20 mA or 4 to 20 mA
  • Analog Input Accuracy ±0.2% FS
    ±0.2% FS
  • Control/Alarm Outputs, Maximum 2
    2
  • Control Algorithms Autotune PID Manual Control Mode Remote Setpoint
    Autotune PID Manual Control Mode Remote Setpoint
  • Display Color Green
    Green
  • Display Digit Height 9.2 mm 14 mm
    9.2 mm 14 mm
  • Maximum Ambient Humidity 90% RH non-condensing
    90% RH non-condensing
  • Maximum Ambient Temperature 55 {C} (131 {F})
    55 {C} (131 {F})
  • Measurement Type Temperature
    Temperature
  • Minimum Ambient Temperature 0 {C} (32 {F})
    0 {C} (32 {F})
  • Number of Display Lines (Sku Variant) 2
    2
  • Other Features (Sku Variant) Recorder Retransmission Low Voltage Power Software
    Recorder Retransmission Low Voltage Power Software
  • RTD Connection 2
    2
  • Remote Setpoint Capability 1 count/0.1 count
    1 count/0.1 count
  • RTD Curves Supported 385
    385
  • RTD Types Supported RTD( 2
    RTD( 2
  • Supply Frequency 50/60 Hz
    50/60 Hz
  • Sampling Rate 0.1
    0.1
  • Thermocouple Type J
    J

The CN8500 Series temperature controller is versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application. A dual digital display offers optimal process information at a glance. The dedicated upper display shows the process temperature, while the lower display displays setpoint and setup parameters. Individual LEDs identify the status outputs, alarms, digital communications, and special options. The CN8500 Series features a NEMA 4X front panel and a universal power supply that accepts 103 to 253 Vac and 103 to 330 Vdc. Control algorithms available are P, PI, PD, PID, and on/off. The autotune feature automatically sets proportional band, rate, and reset before the process reaches setpoint. These parameters provide quick stabilization of both the heating and cooling process without overshoot, hunting, or cycling. The standard dual control outputs can be configured in a variety of control and alarm applications such as heat, heat/cool, heat/alarm, cool, or cool/alarm. The ramp-to-setpoint feature allows the user to define the rate of rise to reach the setpoint, thus minimizing thermal shock to the load during start-up. 

SPECIFICATIONS

Input CodeTypeRangeResolution
TCJ
Iron-constantan
-18 to 760°C1°C
0 to 1400°F1°F
K
CHROMEGA™-ALOMEGA
-18 to 1349°C1°C
0 to 2460°F1°F
T
Copper-constantan
-129 to 316°C1°C
-200 to 600°F1°F
N
OMEGALLOY™
-18 to 1299°C1°C
0 to 2370°F1°F
R
Pt/13% Rh-Pt
-18 to 1299°C1°C
0 to 3200°F1°F
S
Pt/10% Rh-Pt
-18 to 1299°C1°C
0 to 3200°F1°F
RTDRTD
3-wire, 100 Ω Pt
-200 to 850°C1°C
-328 to 1562°F1°F
RTD
3-wire, 100 Ω Pt
-128.8 to 232.2°C0.1°C
-199.0 to 450.0°F0.1°F
V51 to 5 VScalable (-1999 to 9999)Selectable
0 to 5 V
V102 to 10 VScalable (-1999 to 9999)Selectable
0 to 10 V
MV10 to 50 mVScalable (-1999 to 9999)Selectable
0 to 50 mV
MA4 to 29 mAScalable (-1999 to 9999)Selectable
0 to 20 mA


Performance 
Accuracy: ±0.2% FS, ±1 digit 
Setpoint Resolution: 1 count/0.1 count 
Repeatability: ±1.0 count 
Temperature Stability: 5 µV/°C max; 3 ìV/°C typical 
Thermocouple Cold-Junction Tracking: 0.05°C/°C ambient 
Common Mode Rejection: >100 dBA 
Series Mode Rejection: >70 dBA 
Process Sampling: 10 Hz (100 ms) 

Inputs 
Thermocouple Lead Resistance: 100 Ω max for rated accuracy 
Response Time: 0.1, 1.0 or 10 s 
Decimal Position: Selectable 

Outputs 
Output #1: Reverse acting (heating) 
Output #2: Direct acting (cooling) 
Mechanical Relay: Rated 5 A @ 120 Vac, 3 A @ 240 Vac 
Current: 4 to 20 mA, 500 Ω max 
Voltage: 20 Vdc pulse, 1 kΩ min load 
Triac: Solid state relay, 120/240 Vac, zero voltage switched rated 1 A continuous, 10 A surge @ 25°C (77°F) 
Alarms: Optically isolated triac rated 1 A, 120/240 Vac @ 25°C (77°F) 

Control Characteristics 
Setpoint Limits: Limited to configured range for thermocouple and RTD; limited to scaled range 
Alarms: Adjustable for high/low, process or deviation 
Rate: 0 to 900 s 
Reset: 0 to 3600 s 
Cycle Time: 0.2 to 120 s 
Gain: 0 to 400 
Gain Ratio: 0 to 2.0 (in 0.1 increments) 
On/Off Deadband: 1 to 100 counts 
Spread (Output 2): 0 to 100 counts (above setpoint) 
Damping: Adjustable (low, normal or high) 
Ramp to Setpoint: 1 to 100 minutes 
Autotune: Operator-initiated from front panel 
Manual Control: Operator-initiated from front panel 

General 
Power: 115 to 230 Vac ±10%, 50/60 Hz; 115 to 300 Vdc ±10% (auto-polarity) 
Display: Dual LED, 4-digit process display, green menu/parameter display; 9.2 mm (0.37") high for 1/8 DIN models; 14 mm (0.55") process display for 1/4 DIN units 
Power Consumption: Less than 6 VA (instrument) @ 120 Vac 
Weight (1/8 DIN): 0.34 kg (12 oz) 
Weight (1/4 DIN): 0.425 kg (15 oz) 
Panel Cutout (1/8 DIN): 45 x 92 mm (1.772 x 3.622") 
Panel Cutout (1/4 DIN): 92 mm (3.622") square 
Dimensions (1/8 DIN Horizontal): 53 x 100 mm (2.1 x 3.95"); 18.3 mm (0.72") depth 
Dimensions (1/4 DIN): 100 W x 100 H x 18.3 min bezel (3.95 x 3.95 x 0.72") 
Panel Depth: 100 mm (3.937") 
Front-Panel Rating: NEMA 4X (IP66) 
Operating Ambient Range: 0 to 55°C (32 to 131°F) @ 90% RH max, non-condensing 
Memory Protection: Solid state non-volatile memory 
Connections: Rear barrier strip with locking terminals 
Contacts: Twin bifurcated

en-US