text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Portable Data Logger with 16 or 32 Universal Inputs Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs

Item# OM-SQ2040-2F16

Portable Data Logger with 16 or 32 Universal Inputs Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs Portable Data Logger with 16 or 32 Universal Inputs Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs

Description

The OM-SQ2040 Series combines a higher channel count with the same high performance, comprehensive features and universal inputs as the OM-SQ2020 in a neat compact and portable instrument. Using multiple 24-bit analog to digital convertors, twin processors and removable memory options provide great flexibility to handle a wide range of complex and demanding multichannel applications.

The OM-SQ2040 series are the ideal data loggers for industrial, scientific research and quality assurance applications. The OM-SQ2040 provides standalone data acquisition, advanced networked solutions and data analysis straight out-of-the-box.

Input Connections:
The OM-SQ2040-2F16 data logger has two analog to digital converters (A/D’s) which increases logging flexibility over the OM-2020-1F8 model. The first corresponds to inputs on blocks A, B, C and D and the second corresponds to inputs on blocks G, H, J and K. Each connection block will accept up to 2 differential inputs or up to 4 single-ended inputs (it is not possible to mix single ended and differential inputs on a block). The OM-SQ2040-4F16 data logger has four analog to digital converters (A/D’s) which increases logging flexibility over the other OM-SQ2020 and OM-SQ2040 models. The first corresponds to inputs on blocks A and B, the second corresponds to inputs on blocks C and D, the third corresponds to inputs on blocks G and H and the fourth corresponds to inputs on blocks J and K. Each connection block will accept up to 2 differential inputs or up to 4 single— ended inputs (it is not possible to mix single-ended and differential inputs on a block).

Concurrent Sampling:
The OM-SQ2040 series uses |multiple analog to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100 Hz while retaining different sample speeds on other channels. This makes the OM-SQ2040 ideal for measuring dynamic parameters that change at different rates such as temperature and pressure.

Communications:
Ethernet, Wi-Fi (on the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading. This flexibility enables global data access and retrieval as well as complete system integration of the OM-SQ2040 series into complex and critical applications.

Multiple Configurations Stored in the Logger:
Up to six logger configurations (channel type, names, logging speeds, triggers, etc.), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC.

Comprehensive Software Configuration
The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2040. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2040 data logger in a familiar Explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get astatistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels.

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.
OM-SQ2040-2F16
  • 16 True Differential or 32 Single-Ended Universal Analog Inputs for Voltage, Current or Resistance Measurements - Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs
  • Analog Inputs Can Be Used with Thermistors, Thermocouples, 2, 3 or 4-Wire RTD Temperature Sensors and 4 to 20 mA Signals
  • User Selectable Logging Rates of Up to 100 Hz on Up to 4 Channels
  • Download of Internal Data to Removable MMC/SD (Multi Media Card/Secure Digital) Memory
  • Large Non-Volatile Internal Memory - Data Retention is Virtually Indefinite
  • Ethernet, Wi-FI (On the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 Communication Ports
  • Ethernet, USB and RS-232 Communication Ports
  • Sensor Power and FET Alarm Outputs For Use With External Devices
  • Easy Access to Information Using the 2 Line, 20 Character LCD and Push Button Panel
  • Calculated Channels Derived from Real Channels Using Advanced Mathematical Functions
Number of Inputs
Measurement Type
Input Type
Data Points (Records) / Channel
Max Sampling Rate
Accuracy Rating
Display Type
Form Factor
Certificate
Power Supply Option
Communication
Additional Features
 This item is available for quick shipping
See All Options
Quantity Price each
1-4 $3,462.00
5-9 $3,288.90
10-24 $3,219.66
25-49 $3,081.18
50-99 $3,011.94
100+ $2,942.70

In stock

Lead Time ( If not in Stock): 2 weeks

Product Specs

  • Common Mode Rejection Ratio 100 dB
  • Analog Input Impedance >1 MΩ
  • Analog to Digital Converter Type Sigma-Delta
  • Display Type 2 line x 20 character LCD display battery state and external power indicator keypad lock
  • Display Size 2 line x 20 character
  • Maximum Ambient Temperature 65°C (150°F)
  • Minimum Ambient Temperature -30°C (-22°F)

Description

The OM-SQ2040 Series combines a higher channel count with the same high performance, comprehensive features and universal inputs as the OM-SQ2020 in a neat compact and portable instrument. Using multiple 24-bit analog to digital convertors, twin processors and removable memory options provide great flexibility to handle a wide range of complex and demanding multichannel applications.

The OM-SQ2040 series are the ideal data loggers for industrial, scientific research and quality assurance applications. The OM-SQ2040 provides standalone data acquisition, advanced networked solutions and data analysis straight out-of-the-box.

Input Connections:
The OM-SQ2040-2F16 data logger has two analog to digital converters (A/D’s) which increases logging flexibility over the OM-2020-1F8 model. The first corresponds to inputs on blocks A, B, C and D and the second corresponds to inputs on blocks G, H, J and K. Each connection block will accept up to 2 differential inputs or up to 4 single-ended inputs (it is not possible to mix single ended and differential inputs on a block). The OM-SQ2040-4F16 data logger has four analog to digital converters (A/D’s) which increases logging flexibility over the other OM-SQ2020 and OM-SQ2040 models. The first corresponds to inputs on blocks A and B, the second corresponds to inputs on blocks C and D, the third corresponds to inputs on blocks G and H and the fourth corresponds to inputs on blocks J and K. Each connection block will accept up to 2 differential inputs or up to 4 single— ended inputs (it is not possible to mix single-ended and differential inputs on a block).

Concurrent Sampling:
The OM-SQ2040 series uses |multiple analog to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100 Hz while retaining different sample speeds on other channels. This makes the OM-SQ2040 ideal for measuring dynamic parameters that change at different rates such as temperature and pressure.

Communications:
Ethernet, Wi-Fi (on the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading. This flexibility enables global data access and retrieval as well as complete system integration of the OM-SQ2040 series into complex and critical applications.

Multiple Configurations Stored in the Logger:
Up to six logger configurations (channel type, names, logging speeds, triggers, etc.), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC.

Comprehensive Software Configuration
The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2040. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2040 data logger in a familiar Explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get astatistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels.

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.

  • CE Icon CE

en-US
en
Save Configuration