text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

1/8 DIN Dual Input Process Panel Meter

Item# DP6060-6H0

1/8 DIN Dual Input Process Panel Meter 1/8 DIN Dual Input Process Panel Meter

Description

The DP6060 Series process meter combines two independently programmed analog inputs with powerful math functions to make an advanced meter capable of handling complex math requirements common in the process industry. Various math functions may be applied to the inputs including addition, difference, average, multiplication, division, ratio, and more. A customizable dual-line display allows a wide variety of input variables, math calculations, or units and tags to be displayed based on your application needs. Sunlight readable display models have an extraordinarily bright LED display. The DP6060 has two red LED displays, an upper display 15 mm (0.60") high, and a lower display 12 mm (0.46") high. Each display is a full 6 digits (-99999 to 999999). The displays can be set up to read input channels (A or B), math function channel C, toggle between A & B, B & C, A & C, A & B & C, toggle between channels A, B, or C & units, the max/min of any of the channels, including the math channel (C), set points, gross (without tare) or net (with tare) and gross values of channel A or B, or the Modbus input. No jumpers to set for input selection. All setup and programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. The Copy feature is used to copy (or clone) all the settings from one DP6060 to other meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adaptor, only an optional cable assembly. The DP6060 minimizes the menu selections by auto-detecting the installed options to determine what menu navigation is required.
DP6060-6H0
  • Modular USB, RS232, RS485 Serial Communication Options and Relays
  • Math Functions: Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, and More
  • 0 to 20 mA, 4 to 20 mA, 0 to 5V, 1 to 5V, and ±10V Inputs
  • Large Dual-Line 6-Digit Display, 15 and 12 mm (0.60 and 0.46")
  • Sunlight Readable Display Models
  • NEMA 4X (IP65) Front
  • Universal 85 to 265 Vac, or 12/24 Vdc Input Power Models
  • Isolated 24 Vdc @ 200 mA Transmitter Power Supply
  • Free Software for Operation, Monitoring, and Programming
Measure Type
Input Type
Number of Inputs
DIN Size
Display Type
Number of Output
Output Type
Max Sampling Rate
Supply Voltage Type
Supply Voltage
Communications Protocol
Accuracy Rating
Other Features
See All Options
Quantity Price each
1-9 $635.00
10-24 $603.25
25-49 $571.50
50-99 $539.75
100-499 $508.00
500+ $476.25

In stock

Lead Time ( If not in Stock): 5 weeks

Product Specs

  • Analog Current Input Ranges 0% RH
  • Housing Material black high impact plastic
  • Maximum Ambient Humidity 90%
  • Minimum Ambient Temperature USB
  • Minimum Storage Temperature -40 {C} (-40 {F})
  • Number of Alarm Outputs, Maximum 85 {C} (185 {F})
  • Number of Display Lines 0 to 20 mA
  • Power 85 to 265 Vac 50/60 Hz
  • RTD Connection -40 {C} (-40 {F})
  • RTD Curves Supported 2
  • Sampling Rate Yes
  • Supply Frequency 50/60 hz

Description

The DP6060 Series process meter combines two independently programmed analog inputs with powerful math functions to make an advanced meter capable of handling complex math requirements common in the process industry. Various math functions may be applied to the inputs including addition, difference, average, multiplication, division, ratio, and more. A customizable dual-line display allows a wide variety of input variables, math calculations, or units and tags to be displayed based on your application needs. Sunlight readable display models have an extraordinarily bright LED display. The DP6060 has two red LED displays, an upper display 15 mm (0.60") high, and a lower display 12 mm (0.46") high. Each display is a full 6 digits (-99999 to 999999). The displays can be set up to read input channels (A or B), math function channel C, toggle between A & B, B & C, A & C, A & B & C, toggle between channels A, B, or C & units, the max/min of any of the channels, including the math channel (C), set points, gross (without tare) or net (with tare) and gross values of channel A or B, or the Modbus input. No jumpers to set for input selection. All setup and programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. The Copy feature is used to copy (or clone) all the settings from one DP6060 to other meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adaptor, only an optional cable assembly. The DP6060 minimizes the menu selections by auto-detecting the installed options to determine what menu navigation is required.