text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

PROGRAMMABLE INTERFACE DISPLAY FOR RATE, TOTAL AND CONTROL COMMANDS

Item# FMI-102

PROGRAMMABLE INTERFACE DISPLAY FOR RATE, TOTAL AND CONTROL COMMANDS PROGRAMMABLE INTERFACE DISPLAY FOR RATE, TOTAL AND CONTROL COMMANDS
The FMI-100 Series is for flowmeters and controllers with analog 0 to 5, 5 to 10, 0 to 10 Vdc or 4 to 20 mA input output interface, where flow indications/control, totalizers or alarm functions are required. Also when re-transmission of the flow rate and/or totalizer functions via optically-isolated pulse output or serial communication is desired. Local or programmable set point control for flow controllers (no host PC presence required). The graphical LCD has large 13 mm (0.51") digits for flow rate and 5.5 mm (0.21") for total and can be set by user to simultaneously show different combination of the flow parameters: flow rate, totalizers, flow alarms, and diagnostic events. All configuration parameter settings are easily accessed via a simple user-interface menu driven by a 6 button key-pad which can be password-protected. For flowmeters and/or flow controllers, FMI-100 provides jumpers selectable for 0 to 5 Vdc or 4 to 20 mA analog set point control signals. The flow rate set point can be adjusted locally via key-pad, remotely via host PC using digital communication interface, or programmed in advance using built-in 16 steps batch table with ramping up/down support. The programmable flow pulse output operates independently from the totalizers and based on configuration settings can provide pulse frequency proportional to instantaneous fluid flow rate. The FMI-100 provides two independent programmable flow totalizers. Both totalizers are updated every 100 ms and can be set to activate different events. Main totalizer accumulated total is backed-up in EEPROM memory every second. And it provides the user with a flexible alarm/warning system that monitors the fluid flow for conditions that fall outside configurable limits as well as visual feedback for the user via the LCD or via an optically-isolated output. All process data and settings can be read and modified manually via local LCD key-pad or through the digital RS232 or RS485 communication interface. Proprietary ASCII software interface command set and free Communication Utility software are provided.
FMI-102
  • Displays Instantaneous and Total Flow
  • Digital RS232 or RS485 Interface (Multi-Drop Up to 64 Devices)
  • Programmable, Optically- Isolated Pulse and Digital Outputs
  • For Use with FMA1700/1800 or FMA5400/5500 Series
  • 16 Point Programmable Controls, With Ramping Up/Down
  • Free Configuration and Monitoring Utility Software
Input Type
Supply Voltage
Communications Protocol
Features
Quantity Price each
1-9 $260.00
10-24 $247.00
25-49 $241.80
50-99 $231.40
100-199 $226.20
200+ $221.00

In stock

Lead Time ( If not in Stock): 4 weeks

Product Specs

  • Baud Rate 1200/2400/4800/9600/19200/38400/57600/115200 baud (user selectable)
  • Functions RATE
  • Maximum Ambient Temperature 0 {C} (32 {F})
  • Minimum Ambient Temperature -10 {C} (14 {F})
  • Output Type 0 to 5 Vdc

The FMI-100 Series is for flowmeters and controllers with analog 0 to 5, 5 to 10, 0 to 10 Vdc or 4 to 20 mA input output interface, where flow indications/control, totalizers or alarm functions are required. Also when re-transmission of the flow rate and/or totalizer functions via optically-isolated pulse output or serial communication is desired. Local or programmable set point control for flow controllers (no host PC presence required). The graphical LCD has large 13 mm (0.51") digits for flow rate and 5.5 mm (0.21") for total and can be set by user to simultaneously show different combination of the flow parameters: flow rate, totalizers, flow alarms, and diagnostic events. All configuration parameter settings are easily accessed via a simple user-interface menu driven by a 6 button key-pad which can be password-protected. For flowmeters and/or flow controllers, FMI-100 provides jumpers selectable for 0 to 5 Vdc or 4 to 20 mA analog set point control signals. The flow rate set point can be adjusted locally via key-pad, remotely via host PC using digital communication interface, or programmed in advance using built-in 16 steps batch table with ramping up/down support. The programmable flow pulse output operates independently from the totalizers and based on configuration settings can provide pulse frequency proportional to instantaneous fluid flow rate. The FMI-100 provides two independent programmable flow totalizers. Both totalizers are updated every 100 ms and can be set to activate different events. Main totalizer accumulated total is backed-up in EEPROM memory every second. And it provides the user with a flexible alarm/warning system that monitors the fluid flow for conditions that fall outside configurable limits as well as visual feedback for the user via the LCD or via an optically-isolated output. All process data and settings can be read and modified manually via local LCD key-pad or through the digital RS232 or RS485 communication interface. Proprietary ASCII software interface command set and free Communication Utility software are provided.