text.skipToContent text.skipToNavigation

Our response to COVID-19 and how remote monitoring can help #remotetogether.

Weather Resistant Non-Contact Infrared Temperature Sensor With Wireless Transmitter

Item# UWIR-2A-Nema-Series

In stock

Lead Time ( If not in Stock): 0 week

Weather Resistant Non-Contact Infrared Temperature Sensor With Wireless Transmitter UWIR-2A-Nema-Series UWIR-2A-Nema-Series
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 1ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • Transmit Data Wirelessly in Real-Time, up to 120 m (440')
  • -18 to 538°C (0 to 1000°F) Measurement Range
  • Adjustable Emissivity from 0.10 to 1.0
  • Low Power Operation and Sleep Mode For Long Battery Life
  • Weather Resistant NEMA 4X (IP65) Enclosure
  • Works with UWTC-REC Receivers for a Complete Wireless System

Product Specs

  • Batteries Included Yes
  • Accuracy Value ±2% rdg or 2.2°C (4°F)
  • Enclosure Material NEMA-4X (IP65) Polycarbonate
  • Battery Type Lithium
  • Battery Life 1.5 years @ 1 sample/minute reading rate @ 25°C (77°F)
  • Indoor Transmission Range Up to 400ft (120m)
  • Maximum Ambient Humidity Less than 95% RH
  • Number of Batteries 1
  • Number of Inputs 1 Input per transmitter
  • Outdoor Transmission Range Up to 400ft (120m)
  • Power Source Battery
  • Sampling Rate Programmable from 1 per minute to 30 per min (1 per 2 sec)
  • Thermocouple Measurement Range -18 to 538°C (0 to 1000°F)
  • Transmission Protocol USB

OMEGA’s new infrared sensor with wireless transmitter features a remote IR sensor and radio wireless transmitter in a NEMA enclosure. The miniature sensor head is ideal for measuring temperatures from
-18 to 538°C (0 to 1000°F) in confined, hard-to-reach places and harsh environments. The wireless transmitter is mounted in a NEMA 4X (IP65) plastic enclosure. When activated the unit will transmit readings continuously at pre-set time interval that was programmed by the user during the initial setup. Each unit measures and transmits IR sensor reading, ambient temperature, RF signal strength and battery condition to the host and is displayed on the PC screen in real time. Each compatible “UW” Series receiver includes free software that converts your PC into a monitor, chart recorder, or data logger. Readings can be saved and later printed or exported to a spreadsheet file.

Specifications
Temperature Range: -18 to 538°C (0 to 1000°F)
Accuracy @ 22°C (72°F) Ambient Temperature and Emissivity of 0.95 or Greater:
±2% rdg or 2.2°C (4°F), whichever is greater
Optical Field of View: 6:1 (distance/ spot size)
Sensor Head Cable: 1.8 m (6') standard; up to 15 m (50') total length capable
Repeatability: ±1% rdg
Spectral Response: 5 to 14 microns
Response Time: 100 ms (0 to 63% of final value)
Emissivity Range: 0.1 to 1.00, adjustable
Operating Temperature
Wireless Transmitter: -10 to 70°C (14 to 158°F)
Sensor Head: 0 to 70°C (32 to 158°F)
Sensor (-HT Model): 0 to 85°C (32 to 185°F)
Sensor Head with OS100-WC (Water Cooling Jacket): 0 to 200°C (32 to 392°F)
Operating Relative Humidity: Less than 95% RH, non-condensing
Water Flow Rate (OS100-WC): 0.25 GPM, room temperature
Thermal Shock: About 30 minutes for 25°C (77°F) abrupt ambient temperature change
Warm-Up Period: 3 minutes
Air Flow Rate (OS100-AP): 1 CFM (0.5 L/s)
Battery Life (Typ): 3 years @ 1 sample/ minute reading rate @ 25°C (77°F)
Laser Sight Accessory (OS100-LS)
  Input:
Infrared temperature
  Resolution: 1°C (1°F)
Range of RF Link:
  Indoor/Urban: Up to 40 m (131')
  Outdoor Line of Sight: Up to 120 m (400')
RF Output Power: 10 dBm (10 mW)
Sample Rate: 2 sec to 2 min
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz direct sequence spread spectrum
Outdoor Line of Sight: Up to 120 m (400')
Wavelength (Color): 630 to 670 nm (red)
Operating Distance (Laser Dot): Up to 9.1 m (30')
Max Output Optical Power: Less than 1 mW @ -6°C (22°F) ambient temperature
European Classification: Class 2, EN60825-1/11.2001
Max Operating Current: 45 mA @ 3 Vdc
FDA Classification: Complies with 21 CFR 1040.10, Class II laser product
Beam Diameter: 5 mm (0.20')
Beam Divergence: <2 mrad
Operating Temperature: 0 to 50°C (32 to 122°F)
Operating Relative Humidity: Less than 95% RH, non-condensing
Power Switch: On/off slide switch on the battery pack
Power Indicator: Red LED
Power: One 3.6V, lithium “C” cell battery (included)
Dimensions: 145.8 L x 94.7 W x 50.8 mm H (5.74 x 3.73 x 2')

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 2ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
Accessories
Replacement battery, C cell 3.6V lithium.
$16.93
41 In Stock

en-US
en
Save Configuration