High Temperature Insertion Type pH and ORP Electrodes
High Temperature Insertion Type Electrode
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-9 | $200.24 |
10-24 | $190.23 |
25-49 | $186.22 |
50-99 | $178.21 |
100-199 | $174.21 |
200+ | $170.20 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- 16 Month Shelf Life
- High Temperature
- High Pressure
- Steam Sterilization
- Easy Installation
PHE-5431-10 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Measurement Type
Range
Features
Wetted Materials
Max Operating Pressure
Max Temperature
Process Connection Type
The high temperature insertion type electrode is designed for periodic exposure to steam sterilization or continuous high temperature. This pH electrode is housed in a durable thermoplastic (PAS) body and is rated for temperatures up to 135°C. The use of the double Porous PTFE liquid junctions with matched viscosity electrolytes provides a reference cell which permits extended periods of pH measurements in the presence of sulfides or other silver complexing agents. This electrode also incorporates pressure compensating devices to protect the electrode from extreme temperature induced pressure deviations. Ten foot cable length and BNC connector are standard.
Application
• High Temperature Environment
• Continuous Processing Applications
• Harsh Conditions
• Steam Sterilization
Specifications
pH Range: 0 to 14 pH
Temperature Range:
-5 to +135°C (23 to 275°F)
Pressure Range: 500 psig @ 25°C
Accuracy: ±0.1% over full range
Impedance: 125 Mohm (standard version)
Reference Cell: Double Junction, KCl/AgCl, KNO3
Reference Junction: Porous PTFE
Wetted Materials: PTFE, Glass membrane, polymer outer body, EPR “O” Rings
Response Time: 95% of reading in 10 seconds
Drift: Less than 2 mV per week
Application
• High Temperature Environment
• Continuous Processing Applications
• Harsh Conditions
• Steam Sterilization
Specifications
pH Range: 0 to 14 pH
Temperature Range:
-5 to +135°C (23 to 275°F)
Pressure Range: 500 psig @ 25°C
Accuracy: ±0.1% over full range
Impedance: 125 Mohm (standard version)
Reference Cell: Double Junction, KCl/AgCl, KNO3
Reference Junction: Porous PTFE
Wetted Materials: PTFE, Glass membrane, polymer outer body, EPR “O” Rings
Response Time: 95% of reading in 10 seconds
Drift: Less than 2 mV per week