text.skipToContent text.skipToNavigation

High Performance Strain Meter, High Resolution 6-Digit Display

High Performance Strain gauge Meter, High Resolution 6-Digit Display

$928.80

Item# DP41-S-DC-A

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $928.80
5-9 $882.36
10-24 $835.92
25-49 $789.48
50-99 $743.04
100+ $696.60

In stock

Lead Time ( If not in Stock): 9 Days

High Performance Strain gauge Meter, High Resolution 6-Digit Display DP41-S-DC-A DP41-S-DC-A
High Performance Strain gauge Meter, High Resolution 6-Digit Display is rated 5.0 out of 5 by 1.
  • y_2020, m_12, d_2, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_DP41-S-DC-A, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 2ms
  • REVIEWS, PRODUCT
  • Compatible with Strain Gage Bridge Sensors or Ratiometric Voltage Sensors
  • Adjustable Filtering Up to 13 Hz
  • Displays Up to 999,999 Counts
  • NEMA-4 Front Panel
  • Remote Tare, Min, Max, Reset and Hold Features
  • Min/Max (Peak/Valley) Detection

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Measurement Type
Input Type
Number of Inputs
Form Factor
Display Type
Max Sampling Rate
Alarm Output
Retransmission Output
Communications
Supply Voltage Type
Additonal Features


Product Specs

The OMEGA ® DP41-S indicators offer exceptional performance in a strain gage meter. The DP41-S has standard built-in excitation. The input range is selected via internal jumpers, and scaling to engineering units is performed using the front keypad. The DP41-S accepts strain gage bridge sensors and ratiometric voltage measurements. Programming the DP41-S is accomplished through the five front panel keypads. If the optional RS-232 or RS-485 communications are installed, the operator can remotely set all display parameters.

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.

Rated 5 out of 5 by from Long time OMEGA customer Never been let down yet by any of their products, I have been purchasing from OMEGA for 20 plus years
Date published: 2017-05-02
  • y_2020, m_12, d_2, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_DP41-S-DC-A, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT

Can we buy JUST the mounting bracket for a # DP41-S-07 meter? We have lost ours which originally came with the unit.

Asked by: Rick 2020
Thank you for your inquiry. Unfortunately a replacement mounting sleeve (bracket) is not available for the DP41 Series
Answered by: JKengineer
Date published: 2020-12-01

Hi, Can I get some information on the RS232 command interface? The baud rate? Input/output data format?

Asked by: Tayo
Tayo, please see page 9-26 of the full manual for the Baud Rates: https://assets.omega.com/manuals/M1291.pdf
Answered by: SAE DVJ
Date published: 2020-11-03

would this device be able to read force in pounds. Would it be compatible to an ENERPAC set which includes an electric hydraulic pump and a hollow plunger hydraulic cylinder?

Asked by: Marvin
Thank you for your inquire This is a process meter that will take inputs for voltages & currents. Also with a output of voltage & current Please contact us directly to discuss further
Answered by: application engineer je
Date published: 2020-10-19

I want to measure the strain of one single strain gauge (quarter bridge) at site. I don't need data acquisition; just simple getting the strain value from display. Can I do it with DP41-S?

Asked by: ecanbay
Hello, thank you for contacting Omega engineering. You will not be able to a single strain gauge with just the DP41-S. You will need a BCM-1 bridge completing module and the DP41-S meter. This is assuming that you have extension wires. For an in depth explanation please email pressure@omega.com
Answered by: SAE DVJ
Date published: 2020-05-28

I did not find this code DP462 ?

Asked by: Steven Lee
The DP460 Series is an older display that has been discontinued for several year. The most current display the would take it's place is either the DP8PT (4 Digits) or the DP8EPT (6 Digits).
Answered by: JKengineer
Date published: 2020-04-17

Beside two pages PDF manual. Do you have full IO&M manual for the meter DP41-S-AR4. if yes, can you send to me?

Asked by: Oliver
Thank you for you question? Please email pressure@omega.com We will be more then happy to assist you with this.
Answered by: application engineer je
Date published: 2020-04-07

What are the dimensions?????????? DEPTH REQUIRED?????????

Asked by: serviceNWIUTB
Panel cutout for this diplay is standard 1/8 DIN 45mm x 92mm (1.78" x 3.64"). Depth behind panel 148.8mm (5.86" max). Height & Width of display in front of panel 48mm x 96mm (1.89'' x 3.78").
Answered by: JKengineer
Date published: 2019-09-19

Does the equipment require PM?

Asked by: Maurice
If the use of PM in your question refers to Phase Modulation the answer would be no. The DP41-S is simply a 115VAC powered scalable digital display. It accepts DC signals to the millivolt, Voltage or milliamp range.
Answered by: jkengineer
Date published: 2019-08-05
  • y_2020, m_12, d_2, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_9
  • loc_en_US, sid_DP41-S-DC-A, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 1ms
  • QUESTIONS, PRODUCT

en-US
en
Save Configuration