Call us at 1-888-826-6342
Connects a PC to sensors and controls via analog and digital inputs and outputs via Windows® software. 16SE/8DI voltage input channels. Universal inputs.
Product Number | Input Type | Number of Inputs | Minimum Number of Analog Inputs | Maximum Analog Input Sample Rate (per second) | Analog Input Resolution (single-ended, bits) | Input Range | Power | Digital I/O | Number of Digital I/O | Interface Protocol | Additional Features | Analog Input Type | Analog Input Class | Number of Analog Inputs | Maximum Sample Rate (per sec) | Analog Input Resolution | Interface Protocol | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Universal
|
16
|
Up to 16 Analog Inputs
|
4000
|
16
|
See Details
|
USB
|
4 I/O
|
Up to 4 Digital Input or Output
|
USB
|
Not Applicable
|
Universal
|
Universal
|
16
|
4000
|
16
|
USB
|
Not Applicable
|
|
Universal
|
16
|
Up to 16 Analog Inputs
|
4000
|
16
|
See Details
|
USB
|
4 I/O
|
Up to 4 Digital Input or Output
|
USB
|
With Isolation
|
Universal
|
Universal
|
16
|
4000
|
16
|
USB
|
With Isolation
|
The OM-DAQ-USB-2401 is a thermocouple or voltage input USB data acquisition module. Accepts 8 differential or 16 single ended inputs. 24-bit resolution and 1kS/s.
Product Number | Analog Input Type | Analog Input Class | Number of Analog Inputs | Maximum Sample Rate (per sec) | Analog Input Resolution | Input Range | Power | Interface Protocol | Additional Features |
---|---|---|---|---|---|---|---|---|---|
|
TC, Process Voltage
|
Temperature, Process
|
8, 16
|
1000
|
24
|
See Details
|
USB
|
USB
|
12 Vdc Excitation
|
TC and Process Inputs. Low power design requires no external power or batteries. High resolution, high sample rate. Multi device support via USB hubs. Digital calibration
Product Number | Analog Input Type | Analog Input Class | Number of Analog Inputs | Maximum Sample Rate (per sec) | Analog Input Resolution | Input Range | Output Type | Number of Outputs | Output Range | Power | Digital I/O | Interface Protocol | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TC, Process Voltage
|
Temperature, Process
|
5, 10
|
80
|
22
|
See Details
|
None
|
None
|
None
|
USB
|
8 I/O
|
USB
|
Additional 2 Freq/Pulse Inputs
|
|
TC, Process Voltage
|
Temperature, Process
|
10, 20
|
80
|
22
|
See Details
|
None
|
None
|
None
|
USB
|
16 I/O
|
USB
|
Additional 4 Freq/Pulse Inputs
|
The OM-NET-TC has eight isolated 24-bit differential thermocouple inputs with 4 S/s maximum sample rate. Integrated CJC sensors and open sensor detection. 8x Digital I/O.
Product Number | Analog Input Type | Analog Input Class | Number of Analog Inputs | Input Range | Power | Digital I/O | Interface Protocol |
---|---|---|---|---|---|---|---|
|
TC
|
Temperature
|
8
|
See Details
|
AC Adaptor
|
8 I/O
|
Ethernet
|
D3000-D4000 Series transmitters take RS-232 or RS-485 signals from any PC and convert to DC analog current or voltage output. Multiple output ranges, 3x Digital Input.
Product Number | Output Type | Number of Outputs | Output Range | Power | Digital I/O | Interface Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
V
|
1
|
±1 V
|
DC
|
3 Inputs
|
RS-232
|
Not Applicable
|
|
V
|
1
|
±1 V
|
DC
|
3 Inputs
|
RS-485
|
Not Applicable
|
|
V
|
1
|
±5 V
|
DC
|
3 Inputs
|
RS-232
|
Not Applicable
|
|
V
|
1
|
±5 V
|
DC
|
3 Inputs
|
RS-485
|
Not Applicable
|
|
V
|
1
|
±10 V
|
DC
|
3 Inputs
|
RS-232
|
Not Applicable
|