Call us at 1-888-826-6342
DRA-ACT-S Series DIN Rail Conditioners are self powered AC Current/Voltage input and convert to either 0-1mA or 0-20mA output. Self powered design.
Product Number | Number of Inputs | Input Type | Input Ranges | Number of Output | Output Type | Response Time/Frequency | Form Factor | Accuracy Rating | Supply Voltage Type | Supply Voltage | Other Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
1
|
AC Current
|
0 to 1 Aac
|
1
|
0 to 20 mA
|
40 to 400 Hz
|
Din Rail
|
Better
|
Self-Powered
|
Not Applicable
|
Not Applicable
|
|
AC Voltage
|
0 to 300 Vac
|
mA
|
Loop
|
4000 V
|
Trim Pot
|
|||||
|
AC Voltage
|
AC Voltage
|
0 to 150 Vac
|
mA
|
Process
|
Loop
|
4000 V
|
Trim Pot
|
|||
|
AC Voltage
|
AC Voltage
|
0 to 300 Vac
|
mA
|
Process
|
Loop
|
4000 V
|
Trim Pot
|
|||
The DRG-AR Series Conditioners are TC, RTC, DC or AC voltage and current input with 2 SPDT Relay Outputs. Field configurable ranges with adjustable setpoints.
Product Number | Input Type | Input Ranges | Output Type | Supply Voltage Type | Additional Feature |
---|---|---|---|---|---|
|
AC Current/Voltage
|
100 mV to 200 V, 10 mA to 100 mA
|
2 Relays
|
DC
|
Field Configurable
|
|
RTD
|
(-200) to 850 °C
|
2 Relays
|
DC
|
Field Configurable
|
The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Display Type | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|---|
|
AC Current/Voltage
|
AC Current/Voltage
|
0 to 5 A, 0 to 300 Vac
|
mA, V
|
Process
|
Programmer
|
AC/DC
|
2300 V
|
Display Programmer
|
The DIN Rail DMD4380 Series converts, amplifies, filters and optically isolates mA or V input signals to process current or voltage outputs. Loop powered w/ 1200V isolation.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mA, V
|
Process
|
0 to 50 Vdc, 0 to 50 mA dc
|
mA, V
|
Process
|
AC
|
1200 V
|
Trim Pot/Switch
|
|
mA, V
|
Process
|
0 to 50 Vdc, 0 to 50 mA dc
|
mA, V
|
Process
|
DC
|
1200 V
|
Trim Pot/Switch
|
The DRSL-SP3 is a repeater/splitter that isolates and converts 1 bipolar process input to 2 process outputs. DIP switch selectable ranges, slim housing, high accuracy.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
mA, V
|
Process
|
±20 mA, ±10Vdc
|
mA, V (x2)
|
Splitter
|
DC
|
300 V
|
Switch
|
Bipolar Splitter
|
TXDIN101 has thermocouple, RTD, and mV input with 4-20mA output. LED display, configuration TX69-CABLE sold separately required to program via PC.
Product Number | Input Type | Input Ranges | Output Type | Display Type |
---|---|---|---|---|
|
Universal (TC, RTD, mV)
|
See Detail Specs
|
mA
|
LED
|
TXDIN400 series transmitters accept thermocouple or RTD input (TX401) or process voltage, current, or resistance (TX402). Configurable via RFID with TX400-RFID accessory.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
TC, RTD, mV
|
Temperature
|
See Detail Specs
|
mA
|
Process
|
Loop
|
1000 V
|
RFID Programmer
|
|
Resistance, mA, mV
|
Process
|
0 to 4K Ohm, 0 to 20 mA, 0 to 10 Vdc
|
mA
|
Process
|
Loop
|
1000 V
|
RFID Programmer
|
The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
RTD
|
Temperature
|
-200 to 850°C
|
mA
|
Process
|
Loop
|
None
|
Switch
|
DRA-ACT-4 Series DIN Rail Conditioners take a 4 wire AC Current/Voltage input and converts to 4-20mA output. AC Powered 115V or optional 230 V power.
Product Number | Number of Inputs | Input Type | Input Ranges | Number of Output | Output Type | Response Time/Frequency | Form Factor | Accuracy Rating | Supply Voltage Type | Supply Voltage | Other Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
1
|
AC Voltage
|
0 to 150 Vac
|
1
|
4 to 20 mA
|
40 to 500 Hz
|
Din Rail
|
Better
|
AC
|
115 Volts
|
4-Wire AC Powered Design
|
|
AC Voltage
|
AC Voltage
|
0 to 400 Vac
|
mA
|
Process
|
AC
|
4000 V
|
Trim Pot
|
|||
|
1
|
AC Voltage
|
0 to 400 Vac
|
1
|
4 to 20 mA
|
40 to 500 Hz
|
Din Rail
|
Better
|
AC
|
230 Volts
|
4-Wire AC Powered Design
|
The DRSP-I Series are DC current splitters that take one 4-20mA input to two 4-20mA outputs w/ AC or DC power. Zero and span adjustments for each output, status LEDs.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mA
|
Process
|
4 to 20 mA
|
mA (x2)
|
Splitter
|
DC
|
1200 V
|
Trim Pot
|
|
mA
|
Process
|
4 to 20 mA
|
mA (x2)
|
Splitter
|
AC
|
1200 V
|
Trim Pot
|
The DRSL-TEMP is an output loop powered temperature signal conditioner. Accepts Type J, Type K, or 2, 3 or 4 wire Pt100 RTD input. Slim housing, high accuracy.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
TC, RTD
|
Temperature
|
J -100 to 1200°C, K -180 to 1372°C, Pt 100 RTD -200 to 850°C
|
mA
|
Process
|
DC
|
300 V
|
Switch
|
The DRC-4710 and 4720 are DIN Rail bridge input signal conditioners that accept bridge (strain gage, load cell, or voltage) inputs and have 0-10Vdc or 4-20mA outputs.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mV
|
Bridge, strain, mV
|
0 to 30 mV dc
|
V
|
Process
|
DC
|
None
|
Switch
|
|
mV
|
Bridge, strain, mV
|
0 to 30 mV dc
|
mA
|
Process
|
DC
|
None
|
Switch
|
TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mV
|
Bridge, strain, mV
|
-38 to 38 mV dc
|
mA, V
|
Process
|
DC
|
500 V
|
Pushbutton/Software
|
The IDRN-IDRX Conditioners are TC, RTD, process, frequency, AC voltage input and provide analog or digital outputs. IDRN provides process out. IDRX provides RS-485 Output.
Product Number | Number of Inputs | Input Type | Input Ranges | Output Type | Other Features |
---|---|---|---|---|---|
|
1
|
Frequency, Pulse
|
Not Applicable
|
2-wire RS-485
|
IDRN-FP
|
|
1
|
Process
|
400 mV to 10 Vdc 0 to 20 mA
|
2-wire RS-485
|
IDRN-PR
|
|
2
|
Frequency, Pulse
|
Not Applicable
|
0 to 10V @ 10 mA max 0 to 20 mA or 4 to 20 mA, 10V compliance
|
IDRX-FP
|
|
1
|
Process
|
400 mV to 10 Vdc 0 to 20 mA
|
0 to 10V @ 10 mA max 0 to 20 mA or 4 to 20 mA, 10V compliance
|
IDRX-PR
|
|
2
|
Strain Gage, Bridge Transducer-Signal
|
0 to 30 mV 0 to 100 mV±100 mV
|
0 to 10V @ 10 mA max 0 to 20 mA or 4 to 20 mA, 10V compliance
|
IDRX-ST
|
The DRG-SC Series Conditioners have models with TC, RTD, Pot, Freq., AC/DC Voltage/Current, Strain/Bridge inputs and field configurable outputs from 0-5V, 0-10V, 0-20mA.
Product Number | Number of Inputs | Input Type | Number of Output | Output Type | Form Factor | Accuracy Rating |
---|---|---|---|---|---|---|
|
1
|
DC Voltage and Current (bipolar)
|
1
|
0 to 5V, 0 to 10V, 0 to 1 mA, 0 to 20 mA, 4 to 20 mA, +-5V, +-10 V
|
Din Rail
|
Good
|
The DRSL-DISPLAY Programmer is required to program DRST-AC, DRST-DC, DRST-UN, DRST-UR, DRSL-U devices. Snaps onto the front panel with transferable configurations.
Product Number | Input Type | Input Ranges |
---|---|---|
|
Not Applicable
|
Not Applicable
|
TXDIN1600 series has a universal thermocouple, RTD, or process input and 4-20mA output. Configuration via USB cable (sold separately). Push button user trim, relay output
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
TC, RTD, mA, mV
|
Universal
|
See Detail Specs
|
V
|
Process
|
DC
|
500 V
|
Pushbutton/Software
|
|
TC, RTD, mA, mV
|
Universal
|
See Detail Specs
|
2 Relays
|
Relay
|
DC
|
500 V
|
Pushbutton/Software
|
DIN-100 Conditioners convert analog signals to RS-485 to a PC or other processor based equipment. Input types are temperature, bridge, V or mA, D I/O. NV memory storage.
Product Number | Input Type | Input Ranges | Output Type | Additional Feature | |
---|---|---|---|---|---|
|
Voltage
|
+5V
|
Rs 485
|
Not Applicable
|
|
|
1
|
Voltage
|
+100 V
|
RS-485
|
Din Rail
|
|
1
|
Bridge
|
+30 mV 10V excitation
|
RS-485
|
|
|
1
|
Bridge
|
+100 mV 10V excitation
|
RS-485
|
|
The DRC-8900 Series Conditioners are available with TC, RTD, or mA inputs and Voltage outputs. Inputs and outputs are isolated and linearized. 24Vdc power w/ slim housing.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mA
|
Process
|
4 to 20 mA
|
V
|
Process
|
DC
|
700 V
|
Trim Pot
|
|
TC (J)
|
Temperature
|
0 to 500°C
|
V
|
Process
|
DC
|
700 V
|
Trim Pot
|
|
RTD
|
Temperature
|
100 Ohm
|
V
|
Process
|
DC
|
700 V
|
Trim Pot
|
The DRSL-LPO Series Conditioners are 1 or 2 channel output loop powered 2 wire isolators. 1:1 signal ratio, low voltage drop, slim housing. 0.05% accuracy.
Product Number | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
mA
|
Process
|
4 to 20 mA
|
mA
|
Process
|
DC
|
300 V
|
Switch
|
1-Channel
|
|
mA
|
Process
|
4 to 20 mA
|
mA
|
Process
|
DC
|
300 V
|
Switch
|
2-Channel
|