DUAL PULSE TIMER/Totalizer, Wall Mount, NEMA 4
DUAL PULSE TIMER
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-9 | $761.60 |
10-24 | $723.52 |
25-49 | $708.29 |
50-99 | $677.82 |
100-199 | $662.59 |
200+ | $647.36 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
DPT35S Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Alarm Output
Measurement Type
Input Type
Number of Inputs
Form Factor
Display Type
Max Sampling Rate
Retransmission Output
Supply Voltage Type
Additonal Features
The DPT35 digital counter-timer is designed to be used with OMEGA™ (or similar) meters and flow sensors that produce a pulse signal. It is typically used in water treatment and chemical dosing applications, most often in cooling towers and boilers. The DPT35 serves as either a single or a dual timer, depending on whether one or both of its independent accumulators and timers are used. When the DPT35 is used as a single timer, the accumulator counts the pulses coming from the meter. When a pre-set number of pulses has been reached, output power turns on for a set time, and then the cycle repeats. For applications requiring dual timers (typically, one chemical feed and one water bleed), both accumulators and timers are set to operate independently, even though input is from a single meter or flow sensor. A sequential function can be selected to lock one timer out while the other is operating, this prevents feed and bleed from occurring simultaneously.
SPECIFICATIONS
Power: 115 Vac
Sensor Power: 12 Vdc
Output (2): 115 Vac
Enclosure: 127 x 178 mm (5 x 7') polycarbonate
Accumulator Range: 1 to 9999 pulses
Timer Range: 1 to 9999 seconds
Maximum Input: Frequency 1000 Hz
Relay Contact Rating: 5 A resistive @ 115 Vac, or 1/4 HP
Temperature: 0 to 55°C (32 to 130°F)
Weight: 4 lbs (64 oz)
SPECIFICATIONS
Power: 115 Vac
Sensor Power: 12 Vdc
Output (2): 115 Vac
Enclosure: 127 x 178 mm (5 x 7') polycarbonate
Accumulator Range: 1 to 9999 pulses
Timer Range: 1 to 9999 seconds
Maximum Input: Frequency 1000 Hz
Relay Contact Rating: 5 A resistive @ 115 Vac, or 1/4 HP
Temperature: 0 to 55°C (32 to 130°F)
Weight: 4 lbs (64 oz)