text.skipToContent text.skipToNavigation

DISCONTINUED - Low Flow Turbine Meters Stainless Steel Construction

Item# FLR1000ST


DISCONTINUED - Low Flow Turbine Meters Stainless Steel Construction FLR1000ST FLR1000ST
  • ±1% Accuracy
  • 0.2% Repeatability
  • Available with 0 to 5V, 4 to 20 mA, or Pulse Output
  • Available With or Without Display
5 Year Warranty


Product Specs

  • Accuracy Value ±1% FS
  • electrical Connection 4-pin male connector for both power and signal included with 0.9 m (3') cable
  • Maximum Operating Pressure 34 bar (500 psig)
  • Maximum Ambient Temperature 55°C (131°F)
  • Minimum Ambient Temperature 5°C (41°F)
  • Retransmission/Analog Output Linear 0 to 5 Vdc or 4 to 20 mA non-isolated signal

Designed for applications where stainless steel may be required, the FLR1000ST Series flowmeters are rated to 500 psig. These units are available to cover flow ranges from 13 mL/min to 10 L/min. Not for use with Hydrogen or Helium. A 0 to 5 Vdc or 4 to 20 mA analog output is standard with all units; Voltage output models are also available with an additional pulse output, or with a 3 1/2 digit LCD readout.

SPECIFICATIONS
Accuracy/Linearity: ±1% FS
Repeatability: ±0.2% FS
Pressure Rating: 34 bar (500 psig), maximum
Operating Ambient: 5 to 55°C (41 to 131°F)
Storage Ambient: 0 to 70°C (32 to 158°F)
Temperature Sensitivity: = ±0.2% FS/°C
Wetted Parts: 316 SS, epoxy, Pyrex® glass, PPS, FKM O-rings, sapphire bearings
Filtration (Recommended): 25 microns or less
Analog Output: Linear 0 to 5 Vdc or 4 to 20 mA; non-isolated signal
Pipe Connections: 316 SS compression tube fittings, provided
Electrical Connections: 4-pin male connector for both power and signal; included with 0.9 m (3') cable
Power:
    Voltage Output Models: 11.5 to 12.5 Vdc (0.4 W @ 12 Vdc)
    Current Output Models: 18 to 24 Vdc (1.2 W @ 24 Vdc), 50 mA

Rated 5 out of 5 by from flowmeter FLR1012 it is good, accurate and like what i expected, thanks
Date published: 2016-03-18
Rated 5 out of 5 by from Needs flow direction mark on housing. Great product but, the flow direction is not marked on the actual units I got.
Date published: 2017-11-14
  • y_2020, m_4, d_14, h_12
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.5
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_FLR1000ST, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 1ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • CE Icon CE

en-US
en
Save Configuration