Lightweight, Aluminum S-Beam Load Cells
500 lbf, ±0.03%, Linearity, 3 mV/V Output, Cable
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $434.57 |
5-9 | $412.84 |
10-24 | $404.15 |
25-49 | $386.77 |
50-99 | $378.08 |
100+ | $369.38 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- 5-Point NIST Traceable Calibration with
59 kOhm Shunt Cal Data Included - Aluminum for Light Weight and Durability
- Calibrated in Tension
- IP65 Level Protection
- LC105 Cable Style or LC115 Connector Style
LC105-500 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Weight Capacity
Height
Width
Length
Connection Type
Cable Length
Measurement Units
Force direction
Linearity
Electrical Output (nominal)
OD
- Hysteresis ±0.02% FSO
- Input Resistance 350 ± 5 Ohms
- Accuracy Value 0.03
- Linearity ±0.03% FSO
- Maximum Ambient Temperature 93 {C} (200 {F})
- Maximum Compensation Temperature 71 {C} (160 {F})
- Measurement Type Load
- Minimum Compensation Temperature 17 {C} (60{F})
- Repeatability ±0.01% FSO
- Safe Overload 150% of Capacity
- Ultimate Overload 300% of Capacity
- Zero Balance ±1% FSO
- Style S Beam
The LC105 & LC115 are also available in metric configurations, with ranges from 0-10 to 0-500 kgf and metric threads. Please see the LCM105 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 3 mV/V ±.0075 mV/V
Linearity: ±0.03% FSO
Hysteresis: ±0.05% FSO
±0.02% FSO
Repeatability: ±0.01% FSO
Zero Balance: ±1% FSO
Operating Temp Range: -40 to 93°C (-40 to 200°F)
Compensated Temp Range: 17 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.002% FSO/°C
Span: 0.002% rdg/°C
Safe Overload: 150% of Capacity
Ultimate Overload: 300% of Capacity
Bridge Resistance: 350 ± 5 Ohms
Full Scale Deflection: 0.25 to 0.50 mm (0.010 to 0.020")
Construction: Aluminum
Electrical (4-conductor shielded cable):
<250 kg: 9 m (30 ft) 24 AWG
>100 kg: 9 m (30 ft) 20 AWG
LC115/LCM115 Mating Connector: PT06F10-6S, sold separately
Compatible Meters: DP41-S and DP25B-S
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 3 mV/V ±.0075 mV/V
Linearity: ±0.03% FSO
Hysteresis: ±0.05% FSO
±0.02% FSO
Repeatability: ±0.01% FSO
Zero Balance: ±1% FSO
Operating Temp Range: -40 to 93°C (-40 to 200°F)
Compensated Temp Range: 17 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.002% FSO/°C
Span: 0.002% rdg/°C
Safe Overload: 150% of Capacity
Ultimate Overload: 300% of Capacity
Bridge Resistance: 350 ± 5 Ohms
Full Scale Deflection: 0.25 to 0.50 mm (0.010 to 0.020")
Construction: Aluminum
Electrical (4-conductor shielded cable):
<250 kg: 9 m (30 ft) 24 AWG
>100 kg: 9 m (30 ft) 20 AWG
LC115/LCM115 Mating Connector: PT06F10-6S, sold separately
Compatible Meters: DP41-S and DP25B-S



Accessories
Accessories & Compatible Meters