Tall, 1.5" OD Through-Hole, Compression Load Cells
150,000 lbf, ±0.5%, Linearity, 2 mV/V Output, Cable
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $1,291.00 |
5-9 | $1,226.45 |
10-24 | $1,200.63 |
25-49 | $1,148.99 |
50-99 | $1,123.17 |
100+ | $1,097.35 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- 5 Point NIST Traceable Calibration with
59 kOhm Shunt Cal Data - All Stainless Steel Construction
- Rugged Industrial Design
LC8302-151-150K Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Weight Capacity
OD
Through hole (ID)/ Threaded hole dimension
Height
Measurement Units
Force direction
Linearity
Electrical Output (nominal)
Connection Type
Cable Length
- Input Resistance 360 Ω minimum
- Accuracy Value 0.5
- Linearity ± 0.5% FSO
- Load Cell Material Stainless Steel
- Maximum Ambient Temperature 121 {C} (250 {F})
- Maximum Compensation Temperature 71 {C} (160 {F})
- Measurement Type Load
- Output Resistance 350 ±5 Ω
- Minimum Compensation Temperature 16 {C} (60 {F})
- Number of Conductors 4
- Repeatability ±0.1% FSO
- Safe Overload 150% of Capacity
- Ultimate Overload 300% of Capacity
- Temperature Effects ±0.009% FSO/°C
- Zero Balance ±2.0% FSO
- Style Through Hole
SPECIFICATIONS
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Linearity: ± 0.5% FSO
Repeatability: ± 0.1% FSO
Zero Balance: ±2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.009% FSO/°C
Span: ±0.018% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ±5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Linearity: ± 0.5% FSO
Repeatability: ± 0.1% FSO
Zero Balance: ±2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.009% FSO/°C
Span: ±0.018% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ±5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable