Metric, Stainless Steel, Beam Load Cell with Overload Stops
1,000 kgf, ±0.03%, Linearity, 3 mV/V Output, CableQuantity | Price each |
---|---|
1-4 | $465.56 |
5-9 | $442.28 |
10-24 | $432.97 |
25-49 | $414.35 |
50-99 | $405.04 |
100+ | $395.73 |
Please add to cart to keep it or exit the configuration
- 5-Point NIST Traceable Calibration with 59 kOhm Shunt Cal Data Provided
- All Stainless Steel Construction
- 0.25% Interchangeable for Multiple Cell Applications
Edit Options
View all modelsNot all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Product Specs
The LCM501 & LCM511 are also available in standard configurations, with 0-100 to 0-100,000 lb ranges. Please see the LC501 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 3 mV/V ±0.25%
5-Point Calibrated (in Compression): 0%, 50%, 100%, 50%, 0% (includes 59 k? shunt cal data)
Linearity: ±0.03% FSO
Hysteresis: ±0.02% FSO
Repeatability: ±0.02% FSO
Zero Balance: ±1% FSO
Operating Temp Range: -34 to 82°C (-30 to 180°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.001% FSO/°F (0.0018%/°C)
Span: ±0.001% FSO/°F (0.0018%/°C)
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Input Resistance: 360 ? minimum
Output Resistance: 350 ±10 ?
FS Deflection: 0.5 mm (0.02") typical
Construction: 17-4 PH stainless steel
Electrical:
LC501/LCM501: 4.6 m (15') 4 conductor shielded cable
LC511/LCM511: 6-pin DT02H-10-6P or equivalent
Mating connector: PT06F10-6S, sold separately