text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Mass Flow Controllers with 20+ Gas Select Function

Item# FMA-2601A

Mass Flow Controllers with 20+ Gas Select Function Mass Flow Controllers with 20+ Gas Select Function
The FMA-2600A Series mass and volumetric flow controllers use the principle of differential pressure within a laminar flow field to determine and control mass flow rate. A laminar flow element (LFE) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop. A differential pressure sensor is used to measure the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).

The controller uses a true proportional valve coupled to the flow body to control flow using the integral PID loop controller. Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas-select feature and the setpoints can be adjusted from the front keypad or via RS232 communications. Volumetric flow, mass flow, absolute pressure, and temperature can all be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 46 m (150').
FMA-2601A
  • 130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
  • Pressure, Temperature, Volumetric Mass Flow Simultaneously Displayed
  • Easy Operator Push Button Interface
  • NIST Traceability Standard
  • Full Scale Ranges from 0.5 SCCM to 3000 LPM
  • Response Time of 100 milliseconds Typical
  • Turndown Ratio of 200:1 Typical
  • Position Insensitive
  • Accuracy: ±(0.8% of reading + 0.2%FS)
  • RS232 Standard
  • No Warm Up Time
Flow Measuring Range
Accuracy Value
Retransmission/Analog Output
Housing Material
Communications Protocol
Flange Type
Display Type
Media Type
Features
See All Options
Quantity Price each
1-4 $2,440.00
5-9 $2,318.00
10-24 $2,269.20
25-49 $2,171.60
50-99 $2,122.80
100+ $2,074.00

In stock

Lead Time ( If not in Stock): 4 weeks

Product Specs

  • Accuracy Value ±(0.8% of reading + 0.2% FS)
  • Connection Type 8-pin circular mini DIN
  • Maximum Ambient Humidity 100% RH
  • Maximum Ambient Temperature 50°C (122°F)
  • Minimum Ambient Humidity 0% RH
  • Measurement Type Flow
  • Minimum Ambient Temperature -10°C (14°F)
  • Pulse Output 0 to 5 Vdc
  • Response Time 100 ms
  • Supply Voltage 12 to 30 Vdc for units 20 SLM and smaller
  • Wetted Materials Small Valve: 303 & 302 Stainless Steel
  • Turndown Ratio 100:1
  • Zero Shift 0.02%/ATM FS/°C
  • Repeatability ±0.2% FS

The FMA-2600A Series mass and volumetric flow controllers use the principle of differential pressure within a laminar flow field to determine and control mass flow rate. A laminar flow element (LFE) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop. A differential pressure sensor is used to measure the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).

The controller uses a true proportional valve coupled to the flow body to control flow using the integral PID loop controller. Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas-select feature and the setpoints can be adjusted from the front keypad or via RS232 communications. Volumetric flow, mass flow, absolute pressure, and temperature can all be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 46 m (150').