text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

High Accuracy High Pressure Low-Flow Meters

Item# FTB501(8.67CK)115VAC

High Accuracy High Pressure Low-Flow Meters High Accuracy High Pressure Low-Flow Meters
FTB500 series low flowmeters offer extremely accurate low flow measurement of liquids. They utilize a pelton wheel-like rotor whose motion is converted by a pickup coil into a pulse output that is proportional to flow . Each flowmeter comes with an integral signal conditioner, powered by either 15-35 Vdc or 115 Vac (opt.) to provide amplified frequency and analog outputs. The signal conditioner corrects for the inherent zero offset of the flowmeter pulse output. It is mounted in a NEMA-4, explosion-resistant enclosure rated for class I, groups C & D, class II, groups E, F, and G.
FTB501(8.67CK)115VAC
  • 1% of Rate Accuracy
  • 1000 psig, 5000 psig Optional
  • For Flows Down to 0.02 GPM
  • Includes dc or ac Powered Signal Conditioner
  • Linear Pulse and Analog Outputs
Flow Measuring Range
Measurement Type
Connection Type
Wetted Materials
Output Type
Features
See All Options
Quantity Price each
1-4 $3,575.00
5-9 $3,396.25
10-24 $3,324.75
25-49 $3,181.75
50-99 $3,110.25
100+ $3,038.75

In stock

Lead Time ( If not in Stock): 8 weeks

Product Specs

  • Accuracy Value ±1% of rdg for pulse
  • Maximum Operating Pressure 1000 psig std
  • Maximum Ambient Temperature 80°C (176°F)
  • Output Signal 0 to 125 Hz
  • Minimum Ambient Temperature -20°C (-4°F)
  • Pressure Drop 10 psid
  • Response time adjustable from 0.5 to 2 seconds
  • Supply Voltage 15 to 35 Vdc std

FTB500 series low flowmeters offer extremely accurate low flow measurement of liquids. They utilize a pelton wheel-like rotor whose motion is converted by a pickup coil into a pulse output that is proportional to flow . Each flowmeter comes with an integral signal conditioner, powered by either 15-35 Vdc or 115 Vac (opt.) to provide amplified frequency and analog outputs. The signal conditioner corrects for the inherent zero offset of the flowmeter pulse output. It is mounted in a NEMA-4, explosion-resistant enclosure rated for class I, groups C & D, class II, groups E, F, and G.