-
All Products
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
- Sign In
- Register
- Resources
- Services
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
- Sign In
- Register
- Home
- Sensors and Sensing Equipment
- Level
- Float Sensor
- FLOAT LEVEL TRANSMITTER
FLOAT LEVEL TRANSMITTER
$984.30
Item# LVR516
Quantity | Price each |
---|---|
1-4 | $984.30 |
5-9 | $935.09 |
10-24 | $915.40 |
25-49 | $876.03 |
50-99 | $856.34 |
100+ | $836.66 |
Please add to cart to keep it or exit the configuration
In stock
FLOAT LEVEL TRANSMITTER LVR516 LVR516
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getAggregateRating, 109ms
- REVIEWS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
- Level Measurement Up to 2 m (6.5') for High Pressure or Temperature applications
- Rugged 316 Stainless Steel Float Guide and Process Mounting Plug
- Polypropylene Junction Box Rated NEMA 4X (IP65) with Conduit Port and Terminal Strip
- Great for High Pressure Applications Up to 200 psi (13.8 bar)
- Use in Applications with Foam or Turbulence
- Loop Powered Output Interfaces Directly with PLC/SCADA or Local Display
Product info
Product Specs
- Accuracy Value 0.25% span in water
- Connection Type 2 NPT
- Float Specific Gravity 0.55 min
- Maximum Operating Pressure 200 psi (13.8 bar)
- Maximum Ambient Temperature 60 {C} 140 {F}
- Maximum Liquid Temperature 85 {C} (185 {F})
- Measurement Type Float
- Minimum Ambient Temperature -40 {C} (-40 {F})
- Minimum Liquid Temperature -40 {C} (-40 {F})
- Supply Voltage 10 to 30 Vdc
The LVR500 Series float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels.
Specifications
Range: 41 to 1222 cm (16 to 48")
Accuracy: 0.25% span in water
Configuration: None, fixed span
Orientation: ±20° from vertical
Specific Gravity: 0.55 min
Supply Voltage: 10 to 30 Vdc
Loop Resistance: 600 ? @ 24 Vdc
Signal Output: 4 to 20 mA, two-wire
Process Temp: -40 to 85°C (-40 to 185°F)
Ambient Temp: -40 to 60°C (-40 to 140°F)
Pressure: 200 psi (13.8 bar)
Enclosure Rating: NEMA 4X (IP65)
Enclosure Material: PP
Conduit Entrance: Single, 1/2 NPT
Process Mount: 2 NPT
Guide-Float Material: 316 SS
Classification: General purpose
Compliance: CE
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getReviews, 23ms
- REVIEWS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getContent, 136ms
- QUESTIONS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
Request an RoHS Status