text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

FLOAT LEVEL TRANSMITTER

Item# LVR516

FLOAT LEVEL TRANSMITTER FLOAT LEVEL TRANSMITTER
The LVR500 Series float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels.
LVR516
  • Level Measurement Up to 2 m (6.5') for High Pressure or Temperature applications
  • Rugged 316 Stainless Steel Float Guide and Process Mounting Plug
  • Polypropylene Junction Box Rated NEMA 4X (IP65) with Conduit Port and Terminal Strip
  • Great for High Pressure Applications Up to 200 psi (13.8 bar)
  • Use in Applications with Foam or Turbulence
  • Loop Powered Output Interfaces Directly with PLC/SCADA or Local Display
Indicating Length
Retransmission/Analog Output (Sku Variant)
Measurment Unit
Quantity Price each
1-4 $984.30
5-9 $935.09
10-24 $915.40
25-49 $876.03
50-99 $856.34
100+ $836.66

In stock

Lead Time ( If not in Stock): 5 weeks

Product Specs

  • Accuracy Value 0.25% span in water
  • Connection Type 2 NPT
  • Float Specific Gravity 0.55 min
  • Maximum Operating Pressure 200 psi (13.8 bar)
  • Maximum Ambient Temperature 60 {C} 140 {F}
  • Maximum Liquid Temperature 85 {C} (185 {F})
  • Measurement Type Float
  • Minimum Ambient Temperature -40 {C} (-40 {F})
  • Minimum Liquid Temperature -40 {C} (-40 {F})
  • Supply Voltage 10 to 30 Vdc

The LVR500 Series float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels.