text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Optical Chilled Mirror Dew Point Transmitter

Item# RHCM-40-AL-D

Optical Chilled Mirror Dew Point Transmitter Optical Chilled Mirror Dew Point Transmitter
The RHCM-40 Series dew point transmitter is an optical chilled mirror high performance hygrometer designed to continuously measure the moisture content in gases. The sensor provides accurate long term repeatability and high reliability performance for process control and energy management. The instrument is powered by 24 Vdc or optional AC universal supply 85 to 230 Vac. The RHCM-40 series uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance RTD to accurately measure that temperature. Options include air temperature and humidity measurement. There are two selectable analog outputs which include 4 to 20 mA, 0 to 5 Vdc, or 0 to 10 Vdc and an RS232 serial port as well as electrically isolated relay contacts.
RHCM-40-AL-D
  • Wall, Duct and Pipe Mount Models
  • Remote Type Models
  • 4-Wire RTD Measurement for Dew Point
  • ±0.2°C Accuracy for Both Dew Point and Temperature
  • Long-Term Stability and Repeatability
  • RS232, Bi-Directional, Serial Output
  • Electronics Housed in IP65 Enclosure (Wall Mount)
  • Aluminum Housing for Other Configurations
  • 2 Analog Outputs (4 to 20 mA/0 to 5 Vdc to 0 to 10 Vdc Selectable) Optional Features
  • Air Temperature and Humidity
  • 2 Line LCD (Graphical Display with 3 Parameters Displayed at One Time)
  • AC Universal Supply 85 to 230 Vac
  • Flow-Through Sample Chamber U High Pressure (20 bar)
Form Factor
Accuracy Value
Probe Type
Response Time
Measurement Units
Enclosure Type
See All Options
Quantity Price each
1-4 $2,970.00
5-9 $2,821.50
10-24 $2,762.10
25-49 $2,643.30
50-99 $2,583.90
100+ $2,524.50

In stock

Lead Time ( If not in Stock): 6 weeks

Product Specs

  • Connection Size Dew Point: 3 m (10') standard
  • Connection Type Cable
  • Battery Type 24 Vdc ±20%
  • Display Type 2 Line LCD (Graphical Display with 3 Parameters Displayed at One Time)
  • Measurement Type Dew Point
  • Measuring Range Dew Point (Standard): -40 to 60°C (-40 to 140°F)
  • Power Source 24 Vdc ±20%
  • Other Features Wall

The RHCM-40 Series dew point transmitter is an optical chilled mirror high performance hygrometer designed to continuously measure the moisture content in gases. The sensor provides accurate long term repeatability and high reliability performance for process control and energy management. The instrument is powered by 24 Vdc or optional AC universal supply 85 to 230 Vac. The RHCM-40 series uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance RTD to accurately measure that temperature. Options include air temperature and humidity measurement. There are two selectable analog outputs which include 4 to 20 mA, 0 to 5 Vdc, or 0 to 10 Vdc and an RS232 serial port as well as electrically isolated relay contacts.

  • CE Icon CE