text.skipToContent text.skipToNavigation

1,000 lbf, ±0.13%, Linearity, Digital Output, USB

$984.30

Item# LC411-1K-USBH

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $984.30
5-9 $935.09
10-24 $915.40
25-49 $876.03
50-99 $856.34
100+ $836.66

In stock

Lead Time ( If not in Stock): 10 weeks

1,000 lbf, ±0.13%, Linearity, Digital Output, USB LC411-1K-USBH LC411-1K-USBH
1,000 lbf, 0.13%, Linearity, Digital Output, USB is rated 4.0 out of 5 by 1.
  • y_2020, m_9, d_16, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_LC411-1K-USBH, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 1ms
  • REVIEWS, PRODUCT
  • High speed USB with up to 1000 Readings per Second with Free Software Included
  • 5-Point NIST Traceable Calibration Provided
  • Free Downloadable Logging and Charting Software
  • USB 2.0 and Below Compatible, Powered Completely by the USB Port
  • Standard USB Connector Termination
  • All Stainless Steel for Harsh Industrial Environments
  • Built-In 59K Shunt Cal Resistor
  • Dual Bridge Models Available

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Weight Capacity
Measurement Units
Force direction
Linearity
Electrical Output (nominal)
OD
Height
Connection Type
Cable Length


Product Specs

  • Linearity ≤3000 lb: ±0.13% FS
  • Maximum Ambient Temperature 80 {C} (176 {})
  • Maximum Compensation Temperature 71 {C} (160 {F})
  • Measurement Type Load
  • Minimum Compensation Temperature 16 {C} (60 {F})
  • Repeatability ±0.05%
  • Response Time Up to 1 ms
  • Safe Overload 150% FS Capacity
  • Ultimate Overload 300% FS Capacity
  • Temperature Effects Zero: 0.0045%FSO/°C (0.003%FSO/°F)
  • Zero Balance ±1.0% FS

The LC411-USBH Series high speed USB load cells connect directly to your computer. No additional power supply is needed. The load cell is powered directly from your computer’s USB port.

FREE OMEGA™ Downloadable Software!
Free OMEGA PC software takes the data from the transmitter directly to the digital domain, turning your laptop or Windows® tablet into a virtual meter, chart recorder, or data logger. Also included are .NET APIs and a command set for command-line access.
Download your free copy today!





SPECIFICATIONS
Excitation: From USB port
Output: Digital (USB 2.0)
5-Point Calibration: Included 0%, 50%, 100%, 50%, 0%
Note: Models > 300,000 lbf are calibrated at 300,000 lbf. Full scale calibrations above 300,000 lb by quotation only.
Response Time: Up to 1 ms; non-impact loading
Linearity:
    ≤3000 lb: ±0.13% full scale
    >3000 lb: ±0.10% full scale
Hysteresis:
    ≤3000 lb: ±0.12% full scale
    >3000 lb: ±0.10% full scale
Repeatability: ±0.05%
Zero Balance: ±1.0% full scale
Operating Temperature: -40 to 80°C (-40 to 176°F)
Compensated Temperature: 16 to 71°C (60 to 160°F)
Thermal Effects:
    Zero: 0.0045%FSO/°C (0.003%FSO/°F)
    Span: 0.006%FSO/°C (0.004%FSO/°F)
Safe Overload: 150% full scale capacity
Ultimate Overload: 300% full scale capacity
Full Scale Deflection: 0.025 to 0.076 mm (0.001 to 0.003") typical
Electrical Connection: 1.8 m (6') cable with standard USB connector
Protection Class: IP65

Rated 4 out of 5 by from Very good overall This load cell is accurate and the user friendly free software interface with the USB is easy to use. The load cell is very heavy and feels very durable, but the thin diaphragm between the center and ring has already been ripped through by relatively light use. Load cell still operates fine, but it would be nice if the durability of this area could be improved.
Date published: 2017-02-16
  • y_2020, m_9, d_16, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_LC411-1K-USBH, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT

how can these load cell be used in dasylab? I was not able to find any information about communication protocol. Can anyone help?

Asked by: ctou
SAE, let me a little bit more specific. the software available in the USBH.zip file has a glitch. when used together with a platinum display, the time synchronisation is going very badly. Basically it records more data points for the USBH unit that for the platinum, although both are selected at same sampling rate. this is very anoying. best regards, CT
Answered by: ctou
Date published: 2020-01-01
  • y_2020, m_9, d_16, h_17CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_LC411-1K-USBH, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 1ms
  • QUESTIONS, PRODUCT
  • CE Icon CE

en-US
en
Save Configuration