text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Through-Hole Bolt Load Cells, 2.00 Inch O.D.

Item# LC8200-1.00-100

Through-Hole Bolt Load Cells, 2.00 Inch O.D. Through-Hole Bolt Load Cells, 2.00 Inch O.D. Through-Hole Bolt Load Cells, 2.00 Inch O.D." LC8200-1.00-100
  • 5 Point NIST Traceable Calibration with
    59 kOhm Shunt Cal Data
  • Low Profile
  • All Stainless Steel Construction
  • Rugged Industrial Design
Weight Capacity
Measurement Units
Style
Linearity
Electrical Output
Through Hole Dimentions Dims
Connection Type
Option
See All Options
Quantity Price each
1-4 $572.00
5-9 $543.40
10-24 $514.80
25-49 $486.20
50-99 $457.60
100+ $429.00

In stock

Lead Time ( If not in Stock): 0 week

Product Specs

  • Input Resistance 360 Ω minimum
  • Accuracy Value 0.5
  • Linearity ±0.5% FSO
  • Load Cell Material 17-4 PH stainless steel
  • Maximum Ambient Temperature 121 {C} (250 {F})
  • Maximum Compensation Temperature 71 {C} (160 {F})
  • Measurement Type Load
  • Output Resistance 350 ±5 Ω
  • Minimum Compensation Temperature 16 {C} (60 {F})
  • Number of Conductors 4
  • Repeatability ±0.1% FSO
  • Safe Overload 150% of Capacity
  • Ultimate Overload 300% of Capacity
  • Temperature Effects Zero: ±0.009% FSO/°C
  • Zero Balance ±2.0% FSO
  • Style Through Hole

Through-Hole Bolt Load Cells, 2.00 Inch O.D."

en-US
en
Save Configuration