text.skipToContent text.skipToNavigation

Our response to COVID-19 and how remote monitoring can help #remotetogether.

Transducers for Vacuum/Absolute/Differential/GageMeasurements for Clean Gases

$128.00

Item# PX141-001D5V

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $128.00
5-9 $121.60
10-24 $119.04
25-49 $113.92
50-99 $111.36
100+ $108.80

In stock

Limited Stock

Transducers for Vacuum/Absolute/Differential/GageMeasurements for Clean Gases PX141-001D5V PX141-001D5V
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • Silicon Diaphragm
  • HIgh Level Output 1-6 Vdc @ 8 Vdc Excitation
  • Pressure, Vacuum, Differential, and Absolute Types
  • Printed Circuit Board Terminals Exit on Opposite Side from the Ports
  • High Impact Plastic Case
  • Accurate, All Models Temperature Compensated

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Pressure Range
Pressure Type
Accuracy Class
Accuracy Value
Output Signal
Electrical Output
Pressure Port Size
Pressure Port Type
Connection/Termination
Additional Options

Product Specs

  • Accuracy Value 1 to 6 Vdc (±2.5 Vdc PX143)
  • Excitation 8 Vdc regulated (7 to 16 limits) @ 8 mA
  • Maximum Compensation Temperature -18°C (0°F)
  • Minimum Compensation Temperature -18°C (0°F)
  • Wetted Materials Silicon Diaphragm
  • Zero Balance 1.0 Vdc ±0.05 (3.50 Vdc ±0.05 PX143)

The PX140 series has been discontinued. Please contact our Pressure Engineering department.

SPECIFICATIONS
Excitation: 8 Vdc regulated (7 to 16 limits) @ 8 mA
Output: 1 to 6 Vdc (±2.5 Vdc PX143)
Linearity: ±0.75% FS BFSL (±1.5% FS PX143)
Hysteresis: 0.15% FS (0.30% FS ≤5 psi range)
Zero Balance: 1.0 Vdc ±0.05 (3.50 Vdc ±0.05 PX143)
Operable Overpressure: 3x range except (60 psi for 30 psi range, 20 psi for 5 psi)
Response Time: 1 ms
MEDIA COMPATIBILITY
Absolute and P1:
Dry gases only
P2: Limited only to those media that will not attack polyester, silicon, borosilicate glass or epoxy adhesive
Compensated Temperature Range: -18 to 63°C (0 to 145°F)

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 23ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

en-US
en
Save Configuration