Cooling Jacket Kit for OS36 and OS36-2 Infrared Thermocouples

$40.67

Item# OS36-MB2

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $40.67
5-9 $38.64
10-24 $37.82
25-49 $36.20
50-99 $35.38
100+ $34.57

In stock

Lead Time ( If not in Stock): 3 weeks

Cooling Jacket Kit for OS36 and OS36-2 Infrared Thermocouples OS36-MB2 OS36-MB2
Cooling Jacket Kit for OS36 and OS36-2 Infrared Thermocouples is rated 4.0 out of 5 by 1.
  • y_2020, m_9, d_20, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_OS36-MB2, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 3ms
  • REVIEWS, PRODUCT
  • Seamless Copper Monotube Cooling Coil
  • Complete Equipment for Air Cooling and/or Water Cooling
  • Air Purge Included
  • Super-Efficient Design for Low Air or Low Water Use
  • Water Cooling to 540°C (1000°F) with as Little as 0.05 gpm (190 cc/min)

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Connection Size


Product Specs

Extraordinarily efficient in design, the OS36-APC needs water flow rate of only 0.05 gpm (190 cc/min.) to protect an infrared thermocouple at 540°C (1000°F). This convenient and inexpensive kit makes it possible to use either the OS36 or OS36-2 with air, water or both for service in harsh environments. Measuring only 25 x 100 mm (4" x 1") overall, the OS36-APC is small enough to fit into tight areas to closely monitor process temperatures up close (in the optimum position). It can withstand the harshest environments with its all stainless steel housing.

Rated 4 out of 5 by from works great Needed a way to keep our IR sensors cool in an oven. The air jacket worked perfect. With only 4PSI of air we were able to keep the sensor working in 300 deg. F surroundings.
Date published: 2019-03-20
  • y_2020, m_9, d_20, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_OS36-MB2, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 1ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • CE Icon CE

en-US
en
Save Configuration