General Purpose RTD (PT100) Probes with No Transition Junction Between Leads and Sheath

$135.41

Item# PR-10-2-100-1/8-9-E-PFA

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-1 $135.41
2-9 $241.28
10-14 $128.64
15-24 $229.22
25-34 $121.87
35-99 $220.33
100-124 $115.10
125-499 $209.32
500-549 $108.33
550-999 $200.43
1000-1099 $101.56
1100+ $191.55

In stock

Lead Time ( If not in Stock): 3 weeks

General Purpose RTD (PT100) Probes with No Transition Junction Between Leads and Sheath PR-10-2-100-1/8-9-E-PFA PR-10-2-100-1/8-9-E-PFA
General Purpose RTD (PT100) Probes with No Transition Junction Between Leads and Sheath is rated 3.0 out of 5 by 3.
  • y_2020, m_9, d_16, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_PR-10-2-100-1-8-9-E-PFA, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 7ms
  • REVIEWS, PRODUCT
  • Temperature Range -200 to 600°C
  • Three Lead Configuration Standard
  • Two Black Leads Connected to Same Side of RTD Element
  • Leads Terminate with 3 Stripped Wires
  • Alpha = .00385 Standard
  • Accuracy: Class A Per IEC 60751
  • 6, 12, 18, and 24 inch Probe Lengths Standard
  • Ro = 100Ω @ 0°C

    OPTIONS
  • Shrink Tubing Strain Relief at End of Sheath
  • Two and Four Lead Configurations
  • PFA Coating of Probe
  • Stainless Steel Overbraid for 3/16' and 1/4' diameter probes
  • Alpha = .00392
  • Non-Standard Probe Lengths
  • Other Values of Ro

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination or click the CONFIGURE button to build your own.

Category
Process Temperature Range
Sensor Application
Accuracy
Nominal Resistance
Number of Wires
Sheath Material
Probe Diameter
Probe Length
Cable Insulation
Wire Gauge
Cable Length
Termination Connection Type
Additional Feature


Product Specs

This general purpose RTD probe transitions directly to 36' lead wires without the use of a metal transition fitting. This design makes for a more compact probe when space limitations are a factor. Note that the point where the lead wire exits the probe sheath will not be as durable as on the PR-11 probe, which uses the metal transition and spring as strain relief.

For special options consult Sales or Temperature Engineering for availability and pricing.

Rated 3 out of 5 by from Nice design - Required proprieatay connector I bought an Omega data logger with 4 thermocouple inputs and 2 RTD connections. The device worked right out of the box - is easy to use and record with. Unfortunately Omega has designed the data logger so that we have to use their proprietary connectors , almost like an earphone jack, for the RTDs. My master technician tried to solder these connects and messed one of them up. Called up Omega. 3 week lead time, and no they would not replace the connector. a Little disappointed on that front. Very limited instructions on how to solder this connector. We guessed as to what terminal goes to what RTD wire and took an educated guess. Lucky for us our guess was right.
Date published: 2018-03-26
Rated 2 out of 5 by from RTD Bad Ground The RTD is a three wire unit that appears robust and arrived in the configuration that was ordered. However, when it was connected to the digital controller for the oven, the sensor signal was lost each time the oven reached about 120 F. Tracing the issue revealed that one of the ground wires from the RTD had a bad connection. Just touching the wire as it exited the sensor would cause it to loss connection. The wire was not strained during installation given the generous space afforded by the oven. Since my lead wire is only 6' long, I am not so concerned about the added accuracy a 3-wire RTD offers over a 2-wire. So, I placed a jumper on the controller to connect both of the grounds together. If the lead time for ordering a new RTD was not so long, I would have returned this defective unit.
Date published: 2020-08-21
Rated 4 out of 5 by from Good for static measurement, response time varies Easy to use, accurate devices. Warning, I saw different response times between the two devices I ordered when the temperature was changing rapidly. One responded to an 80 C difference in ~ 1 min, the other took 5 min to stabilize.
Date published: 2020-07-20
  • y_2020, m_9, d_16, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_PR-10-2-100-1-8-9-E-PFA, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 1ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

en-US
en
Save Configuration