text.skipToContent text.skipToNavigation

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Please validate your credit card and billing information.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please validate your credit card and billing information.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter first name
Please enter last name
Please enter a zipcode
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
Zipcode is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated
Required Fields Missing or incorrect.
Required Fields Missing or incorrect.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, something went wrong on our side, please try again later or contact Customer Service.
We're sorry, something went wrong on our side, please contact Customer Service to avoid duplication.
We're sorry, something went wrong on our side, please contact Customer Service to avoid duplication.
Please confirm that you have entered the correct information for this credit card number.
We're sorry, there was an issue with your credit card, please contact your issuing bank.
This card is expired, please update the information or try another card.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, we're having trouble contacting your bank. Please try again later.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
Required Fields Missing or incorrect.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
Please confirm that you have entered the correct information for this credit card number.
Required Fields Missing or incorrect
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, there was an issue with your credit card, please try another form of payment.
We're sorry, something went wrong on our side, please try again later or contact Customer Service.
We're sorry, we're having trouble contacting your bank. Please try again later.
Required Fields Missing or incorrect.
We're sorry, something went wrong on our side, please contact Customer Service to avoid duplication.

Calibrator for Thermocouple and RTDs (PT100)

$1,668.00

Item# CL543B

 This item is available for quick shipping
Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $1,668.00
5-9 $1,584.60
10-24 $1,551.24
25-49 $1,484.52
50-99 $1,451.16
100+ $1,417.80

In stock

Lead Time ( If not in Stock): 3 weeks

Calibrator for Thermocouple and RTDs (PT100) CL543B CL543B
  • Calibrate Thermocouple Instruments to 0.1 and 0.01, °F and °C
    Types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), (T-DIN) and P (Platinel): -13.000 to 80.000 mV
  • Calibrate RTD Instruments to 0.1 and 0.01, °F and °C
    Pt 10, 50, 100, 200, 500 and 1000 (3850)
    Pt 100 (alpha = 3902, 3916, 3926)
    Cu 10 and 50 and Ni 120
  • Calibrate with Confidence
    Resolution to 0.01, °F and °C Accurate to 0.2°
    Cold Junction Sensor Accurate to 0.05°C
    NIST Traceable Cold Junction Sensor in Isothermal Block
  • Troubleshoot RTD Sensors and Instruments
    Automatic Detection of 2-, 3- or 4-Wire Connections Indicates When Individual Wire Connections are Open
    Verify Proper Instrument Operation by Measuring the Excitation Current
  • Fast Easy Calibrations
    Instantly Select 3 Outputs with the EZ-CHECK Switch
    Easily Find Trip Points with 2 Speed EZ-DIAL Knob and Automatic Stepping
  • Verify Resistance, Cold Junction Temperature and Output
    Secondary Display of Resistance for RTDs and Compensated millivolt Setting, and Cold Junction Temperature for Thermocouple
  • Use in the Plant, Field or Shop
    Includes Rubber Boot and mV Test Leads
    Low Profile Switches Resist Accidental Damage
    Brass Screws for Thermocouple Wires Plus Miniature Thermocouple Socket
  • Perform Heat Treating Surveys and Accuracy Tests
    Meets or Exceeds the Requirement of AMS 2750 as Both a Secondary Standard Instrument and as a Field Test Instrument
  • NIST Cert (No Points)

Product info

Power Source
Battery
Battery Run Time
50 Hours
Measurement Type
Temperature
Batteries Included
Yes
Form Factor
Portable
Input Type
Thermocouple, Millivolt

Product Specs

  • battery Life 50 hours
  • Battery Size AA
  • Battery Type Alkaline
  • Display Type High contrast graphic liquid crystal display
  • Maximum Ambient Temperature 60°C (140°F)
  • Measurement Units °C or °F
  • Minimum Ambient Temperature -20°C (-4°F)

THERMOCOUPLE CONNECTIONS
Simulating or reading thermocouples requires the use of thermocouple or extension grade thermocouple wire. Plug thermocouple wires into the miniature thermocouple jack or place bare thermocouple wires onto the brass block under the screws.

The CL543B has two banana jacks (1+ and 2-) mounted in the top end of the housing. These are not temperature compensated and are to be used only for millivolt signals.

RTD CONNECTIONS
Simulating or reading RTDs uses copper wire. Plug 2-, 3- or 4-wires into the corresponding jacks on the calibrator. For RTD source the CL543B simulates the (+) RTD from jacks 1 and 4 and the (-) RTD from jacks 2 and 3. When reading an RTD sensor the CL543B uses patented circuitry to automatically detects if 2-, 3- or 4-wires are connected. This is helpful to troubleshoot sensor connections.

Specifications
Operating Temperature Range: -20 to 60°C (-5 to 140°F)
Storage Temperature Range: -30 to 60°C (-22 to 140°F)
Temperature Effect: ?±25 ppm/°C of range
Cold Junction Sensor: ?±0.01% °/° from ambient temperature (°C or °F)
Relative Humidity Range:
    10% ?RH ?90% (0 to 35°C), non-condensing
    10% ?RH ?70% (35 to 60°C), non-condensing
Normal Mode Rejection: 50/60 Hz, 50 dB
Common Mode Rejection: 50/60 Hz, 120 dB
Dimensions: 143 L x 76 W x 41 mm H (5.63 x 3 x 1.60")
Weight: 0.34 kg (12.1 oz) with boot and batteries
Batteries: Four “AA” alkaline 1.5V (LR6) (included), optional NiMh rechargeable battery kit [120 Vac (North America only); charger, 4 NiMh batteries, AC and DC cords
Battery Life: 50 hours, low battery indication with nominal 1 hour of operation left
Over-Voltage Protection: Up to 60 vrms (rated for 30 seconds), protection against misconnection
Alerts: Red LED displays OVERLOAD or out of range conditions
Display: High contrast graphic liquid crystal display, LED backlighting for use in low lit areas
Voltage Source
Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV
Accuracy: ±(0.008% of setting + 0.006 mV)
Source Current: ?10 mA
Output Impedance: <0.3?
RMS Noise: ?±0.0005 mV from 0.1 to 10 Hz
Short Circuit Duration: Infinite Voltage Read
Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV
Accuracy: ±(0.008% of reading + 0.006 mV)
Input resistance: ?10 M? Thermocouple Source
Accuracy: ±(0.008% of setting + 0.006 mV)
Cold Junction Compensation: ±0.05°C (±0.09°F); thermistor traceable to NIST for 11 years
Output Impedance: <0.3?
Source Current: >10 mA (drives 80 mV into 10?)
RMS Noise: ?±0.0005 mV from 0.1 to 10 Hz
Thermocouple Read
Accuracy: ±(0.008% of reading + 0.006 mV)
Cold Junction Compensation: ±0.09°F (±0.05°C); thermistor traceable to NIST for 11 years
Input Impedance: >10 M?
Open Thermocouple Threshold: 10,000? nominal
Pulse: <10 microamp pulse for 300 milliseconds
RTD and O Source
3- and 4-Wire Accuracy:
    From 1 to 10.2 mA External Excitation Current: ±(0.015% of setting + 0.05?)
    Below 1 mA of External Excitation Current: Add (0.025 mV/mA excitation current)
2-Wire Accuracy: Add 0.1? to 3-wire and 4-wire accuracy
Resistance Ranges:
    400? Range: 0.00 to 401.00 and 0.000 to 401.000
    4000? Range: 0.0 to 4010.0 and 0.00 to 4010.00
RMS Noise:
    400? Range: ?±0.005? from 0.1 to 10 Hz
    4000? Range: ?±0.05? from 0.1 to 10 Hz
Allowable Excitation Current Range:
    400? Range: 10.2 mA max; steady or pulsed/intermittent
    4000? Range: 1 mA max; steady or pulsed/intermittent
Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width, 0.025 mV, mA excitation current
RTD and Ohms Read
Resistance Ranges:
    400? Range: 0.00 to 401.00 and 0.000 to 401.000
    4000? Range: 0.0 to 4010.0 and 0.00 to 4010.00
Accuracy: ±(0.015% of reading + 0.05?)
Excitation Current: 0.9 mA to 401?, 0.4 mA to 4010? (nominal)

  • CE Icon CE