text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

RTD Thermometers

Item# 869C

RTD Thermometers RTD Thermometers
SPECIFICATIONS

Sensor: 3- or 4-wire 100 Ω Platinum RTD α=0.00385
Accuracy: Includes DIN 43760 conformity (no points), repeatability, temperature coefficient (18 to 28°C ambient), time stability (1 year) and errors with up to 50 Ω of resistance in each lead; excluded probe errors
Repeatability: Less than 0.2°F typical for one week at constant ambient temperature
Temperature Coefficient: 18 to 28°C (64 to 82°F); included in accuracy specification; less than 18°C (64°F) or greater than 28°C (82°F) less than ±(0.015°C)/°C
Maximum Lead Resistance: 4-wire:50 Ω max; 3-wire: 10 Ω max
Display: 3½ digit LCD, 13 mm (0.5") height; polarity, decimal point, open sensor and overrange indication
Reading Rate: 1.5 per second
Battery Life: 500 hours typical, with 9V alkaline battery (included)
Battery Indicator: Display reads "LO BAT" when less than 10% of life remains
Linearization: Ratiometric dual-slope A/D with continuous linearization
Mating Connection: OMEGA™ series T instrumentation connectors (model TA4F and TA4FL), see section G
Environmental Limits: Operating: -10 to 50°C (14 to 122°F), less than 80% RH, up to 35°C
Storage: -35 to 60°C (-31 to 140°F), less than 90% RH, up to 35°C
Maximum Common Mode Voltage: 42V peak
Dimensions: 160 H x 69 W x 31 D mm(6.3 x 2.7 x 1.2")
Net Weight: 210 g (7.5 oz)
                   
869C
  • Each Unit Comes with Certificate Stating NIST Traceability and ANSI/Z540-1-1994 Compliance
  • 3- and 4-wire RTD’s
  • Accurate
  • 0.1° and 1° Resolution
  • Compact and Rugged
  • DIN 43760 Standard
Sensor Type
Minimum Temperature Measurement
Maximum Temperature Measurement
Connection Type
Display Type
Accuracy Value
Resolution
Stem Length
Dial Diameter
Form Factor
Input Voltage
Battery Type
Measurement Type
Number of Inputs
Connection Size
Connection Gender
Retransmission/Analog Output
Probe Size Cable Length
Communications Protocol
Series
Field of View
Immersible
Features
Weight
 This item is available for quick shipping
See All Options
Quantity Price each
1-9 $429.53
10-24 $408.05
25-49 $399.46
50-99 $382.28
100-199 $373.69
200+ $365.10

In stock

Lead Time ( If not in Stock): 6 weeks

Product Specs

SPECIFICATIONS

Sensor: 3- or 4-wire 100 Ω Platinum RTD α=0.00385
Accuracy: Includes DIN 43760 conformity (no points), repeatability, temperature coefficient (18 to 28°C ambient), time stability (1 year) and errors with up to 50 Ω of resistance in each lead; excluded probe errors
Repeatability: Less than 0.2°F typical for one week at constant ambient temperature
Temperature Coefficient: 18 to 28°C (64 to 82°F); included in accuracy specification; less than 18°C (64°F) or greater than 28°C (82°F) less than ±(0.015°C)/°C
Maximum Lead Resistance: 4-wire:50 Ω max; 3-wire: 10 Ω max
Display: 3½ digit LCD, 13 mm (0.5") height; polarity, decimal point, open sensor and overrange indication
Reading Rate: 1.5 per second
Battery Life: 500 hours typical, with 9V alkaline battery (included)
Battery Indicator: Display reads "LO BAT" when less than 10% of life remains
Linearization: Ratiometric dual-slope A/D with continuous linearization
Mating Connection: OMEGA™ series T instrumentation connectors (model TA4F and TA4FL), see section G
Environmental Limits: Operating: -10 to 50°C (14 to 122°F), less than 80% RH, up to 35°C
Storage: -35 to 60°C (-31 to 140°F), less than 90% RH, up to 35°C
Maximum Common Mode Voltage: 42V peak
Dimensions: 160 H x 69 W x 31 D mm(6.3 x 2.7 x 1.2")
Net Weight: 210 g (7.5 oz)
                   

  • CE Icon CE

en-US
en