Call us at 1-888-826-6342
Spring-loaded RTD probes with a powerful 13lb pull magnetic housing ideal for easily mounting to and measuring the surface temperature of ferrous metals up to 400°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style | Maximum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
0 to 100°C (32 to 212°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
PVC
|
Stripped Leads
|
1 m
|
PVC Cable
|
Magnetic Mount
|
100°C
|
|
RTD
|
0 to 400°C (32 to 753°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
Fiberglass
|
Stripped Leads
|
1 m
|
Fiberglass Cable
|
Magnetic Mount
|
400°C
|
|
RTD
|
0 to 400°C (32 to 753°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
Fiberglass
|
Stripped Leads
|
3 m
|
Fiberglass Cable
|
Magnetic Mount
|
400°C
|
|
RTD
|
0 to 100°C (32 to 212°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
PVC
|
Stripped Leads
|
3 m
|
PVC Cable
|
Magnetic Mount
|
100°C
|
|
RTD
|
0 to 200°C (32 to 392°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
Silicone Rubber
|
Stripped Leads
|
1 m
|
Silicone Rubber Cable
|
Magnetic Mount
|
200°C
|
General use fast response thermocouples mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 175°C. IEC color-coded.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Miniature Connector with Molded Strain Relief
|
2 m
|
IEC
|
Standard
|
Not Applicable
|
2 Meter
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
1 Meter
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
2 m
|
IEC
|
Standard
|
Not Applicable
|
2 Meter
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
3 m
|
IEC
|
Standard
|
Not Applicable
|
3 Meter
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
1 Meter
|
Not Applicable
|
The SAP series thermocouple sensors come in curved and flat styles. An adhesive pad holds the sensor onto the measuring surface. These come in types J, K, T and E.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Features |
---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Flat Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
72 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
72 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
The SAP series RTD sensors come in curved and flat styles. An adhesive pad holds the sensor onto the surface to be measured. The RTD element used is Class A platimum 100 Ω.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style |
---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Thin backing for fast response
|
Flat Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
3 m
|
Thin backing for fast response
|
Curved Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Thin backing for fast response
|
Curved Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
80 in
|
Thin backing for fast response
|
Curved Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
3 m
|
Thin backing for fast response
|
Flat Surface Mounting
|
Spring-loaded thermocouple element in a short housing that plugs directly into most handheld thermometers for easy ad-hoc surface temperature measurements up to 218°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Termination Connection Type | Color Code Standard | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 218°C (32 to 425°F)
|
Handheld Meter
|
Miniature Connector
|
ANSI (Standard)
|
Not Applicable
|
Not Applicable
|
General use RTDs molded into a silicone rubber with self-adhesive backing for easily measuring the temperatures of curved or flat surfaces up to 200°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Flexible Molded
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
120 in
|
Sensors For Curved Surfaces
|
Class A DIN Platinum
|
200°C
|
-50°C (-58°F)
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Flexible Molded
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
1 m
|
Sensors For Curved Surfaces
|
Class A DIN Platinum
|
200°C
|
-50°C (-58°F)
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Flexible Molded
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
3 m
|
Sensors For Curved Surfaces
|
Class A DIN Platinum
|
200°C
|
-50°C (-58°F)
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Flexible Molded
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Sensors For Curved Surfaces
|
Class A DIN Platinum
|
200°C
|
-50°C (-58°F)
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Flexible Molded
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
5 m
|
Sensors For Curved Surfaces
|
Class A DIN Platinum
|
200°C
|
-50°C (-58°F)
|
Epoxy encapsulated thermistors in small stainless steel disc-shaped housings ideal for measuring surface temperatures up to 100°C. Glue, epoxy, or cement onto a flat surface.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Cable Insulation | Termination Connection Type | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Disk for Surface
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Disk for Surface
|
2252 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Disk for Surface
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Disk for Surface
|
5000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Disk for Surface
|
30,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
Wire-wound pt100 RTDs encased in a thin polyimide film with fast response times. Can be glued, epoxied, or cemented onto surfaces for temperature measurement up to 290°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.50%
|
3
|
PFA
|
Stripped Leads
|
36 in
|
DIN Platinum
|
260°C (500°F)
|
Old Design
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.25%
|
3
|
PFA
|
Stripped Leads
|
36 in
|
DIN Platinum
|
260°C (500°F)
|
Old Design
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.50%
|
3
|
PFA
|
Stripped Leads
|
60 in
|
DIN Platinum
|
260°C (500°F)
|
New Design
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.50%
|
3
|
PFA
|
Stripped Leads
|
72 in
|
DIN Platinum
|
260°C (500°F)
|
New Design
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.25%
|
3
|
PFA
|
Stripped Leads
|
48 in
|
DIN Platinum
|
260°C (500°F)
|
Old Design
|
Flat leaf-type thermocouples with mini or standard connectors ideal for measuring the surface temperature of objects with layers like plywood, plastic, paper, and laminates.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Additional Features | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 210°C (32 to 410°F)
|
Handheld Surface
|
None
|
Miniature Connector
|
None
|
ANSI (Standard)
|
Overall Foil Length 4.44 in
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 210°C (32 to 410°F)
|
Handheld Surface
|
None
|
Miniature Connector
|
None
|
ANSI (Standard)
|
Overall Foil Length 4.44 in
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 215°C (32 to 420°F)
|
Handheld Surface
|
None
|
Standard Connector
|
None
|
ANSI (Standard)
|
Overall Foil Length 1 in
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 215°C (32 to 420°F)
|
Handheld Surface
|
None
|
Standard Connector
|
None
|
ANSI (Standard)
|
Overall Foil Length 1 in
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 215°C (32 to 420°F)
|
Handheld Surface
|
None
|
Standard Connector
|
None
|
ANSI (Standard)
|
Overall Foil Length 19 in
|
Not Applicable
|
Not Applicable
|
Thermocouple module intended for easily measuring and validating the temperature of soldering iron tips. Use with a handheld thermometer to easily calibrate a soldering iron.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 427°C (32 to 800°F)
|
Solder Iron
|
PFA
|
Miniature Connector
|
18 in
|
ANSI (Standard)
|
Solder Iron
|
Not Applicable
|
Not Applicable
|