text.skipToContent text.skipToNavigation

1 & 2 Channel High Accuracy 0.1% Type K Thermocouple Meter

0.1% Accuracy Handheld Thermometers | Single and Dual Channel Models

$95.36

Item# HH11C

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $95.36
5-9 $90.59
10-24 $88.68
25-49 $84.87
50-99 $82.96
100+ $81.06

In stock

Lead Time (If not in stock): 7 weeks
0.1% Accuracy Handheld Thermometers | Single and Dual Channel Models HH11C HH11C
  • Highly Accurate Thermometer with 0.1% Basic Accuracy
  • Thermocouple Offset Adjust
  • HH12C: Dual Input T1, T2, T1-T2
  • Rugged Protective Holster, Included
  • Auto-Power Off
  • MIN/MAX/AVG/REL/HOLD Functions
  • Wide Measuring Ranges for Versatile Applications

HH11C Model Options

View all models

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Number of Channels
Category
Input Type
Minimum Temperature Measurement
Maximum Temperature Measurement
Input Connection Type
Display Type
Accuracy Value
Resolution
Supply Power
Features


The HH11C and HH12C handheld thermometers feature Type K thermocouple inputs and are available in either single- or dual input models. The HH11C is a single-input model that has auto range resolution of 0.1 or 1°. The HH12C is a dual-input meter that allows the user to display T1, T2, or (T1 – T2) readings with 0.1 or 1° resolution. Both models have a 4½ digit display with a maximum reading of 19999, are °C/°F switchable and feature front-panel offset adjustment and maximum reading/display hold functions. Errors contributed by a particular thermocouple can be practically eliminated, over a limited range, by using the recessed offset adjustment on the face of the meter and an accurate temperature standard. An LED warning light indicates when an open thermocouple input situation exists. Both units also have improved temperature range and humidity specifications.

Specifications
Display: 4½ digit liquid crystal display (LCD) with a maximum reading of 19999
Low Battery Indication: The “battery symbol” is displayed when the battery voltage drops below the operating level
Measurement Rate: 1 times/second
Operating Environment: 0 to 50°C (32 to 122°F) at <80% RH
Storage Temperature: -20 to 60°C (-4 to140°F), 0 to 80% RH with battery removed from meter
Accuracy: Stated accuracy at 23°C (73°F), <80% RH
Battery: 9V (included)
Dimensions: 185 H x 65 W x 35 mm D (7.3 x 2.6 x 1.4')
Weight (Approximately):
    HH11C: 235 g (8.3 oz), including batteries
    HH12C: 240 g (8.5 oz), including batteries
Temperature Range:
    Range: -200 to 1372°C (-328 to 2502°F)
    Autorange: 0.1°C
    Accuracy: ±(0.1% rdg + 0.5°C) on -50 to 1372°C (-58 to 2502°F); ±(0.1% rdg + 2°C) on -50 to -200°C (-58 to -328°F) Type K (Chromic-Alum)
loading all models
loading all reviews
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
loading all QA
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration