Portable Chilled Mirror Dew Point Monitor
Portable Dew Point Monitor
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $7,725.00 |
5-9 | $7,338.75 |
10-24 | $7,184.25 |
25-49 | $6,875.25 |
50-99 | $6,720.75 |
100+ | $6,566.25 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- Primary Field Measurement Technique
- NIST Traceable
- +/- 0.2 deg C
- Rechargeable Batteries
- Easily Transportable in Hard Protective Case
- Wide Measurement Range: -60 to 75°C (-76 to 167°F)
- Microprocessor Controlled
- Self-Balancing
RHB-1500-C1S2 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Maximum Temperature Measurement
Supply Power
Features
Input Type
Display Type
Accuracy Value
This portable dew point hygrometer integrates the accuracy and reliability of the OMEGA™ chilled mirror with the battery life and ruggedness required for field use.
The RHB-1500-C portable chilledmirror hygrometer has all the standard features, such as drift-free NIST-traceable accuracy, low maintenance, high durability, and ease of use—in a system that is ideally suited for the demands of field use. Whether you use the RHB-1500-C as a field transfer standard or to spot-check your process air dryness or dew point, you'll find this system provides trouble-free operation.
The RHB-1500-C is a self-contained system. Not only is no field assembly required, but also there's no need to carry around a myriad of individual components such as control boxes, sensors, cables, pumps, and power cords. Simply attach the sample line, adjust the flow (with the integral flowmeter), and turn on the power. Within minutes you'll be collecting field dew point data with the same chilled-mirror accuracy of a lab-standard hygrometer. And with a nominal battery life of 12 hours, the RHB-1500-C lets you collect for the entire shift or spot-check your processes for several days.
The RHB-1500-C portable chilledmirror hygrometer has all the standard features, such as drift-free NIST-traceable accuracy, low maintenance, high durability, and ease of use—in a system that is ideally suited for the demands of field use. Whether you use the RHB-1500-C as a field transfer standard or to spot-check your process air dryness or dew point, you'll find this system provides trouble-free operation.
The RHB-1500-C is a self-contained system. Not only is no field assembly required, but also there's no need to carry around a myriad of individual components such as control boxes, sensors, cables, pumps, and power cords. Simply attach the sample line, adjust the flow (with the integral flowmeter), and turn on the power. Within minutes you'll be collecting field dew point data with the same chilled-mirror accuracy of a lab-standard hygrometer. And with a nominal battery life of 12 hours, the RHB-1500-C lets you collect for the entire shift or spot-check your processes for several days.


