Call us at 1-888-826-6342
Configurable thermistor probes for immersion applications with 316 SS sheath, strain relief spring and PFA extension cable. Available with selection of resistances and sizes.
Product Number | Category | Sensor Application | Accuracy | Nominal Resistance | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
Transition Joint Style
|
±0.2°C
|
2252 Ω
|
316 Stainless Steel
|
0.125 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
Thermistor
|
Transition Joint Style
|
±0.2°C
|
2252 Ω
|
316 Stainless Steel
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
Thermistor
|
Transition Joint Style
|
±0.2°C
|
3000 Ω
|
316 Stainless Steel
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
Thermistor
|
Transition Joint Style
|
±0.2°C
|
3000 Ω
|
316 Stainless Steel
|
0.125 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
Thermistor
|
Transition Joint Style
|
±0.2°C
|
10,000 Ω
|
316 Stainless Steel
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
Thermocouple probes made with Omegaclad XL sheath material and extension cable. These probes have superior long-term stability and low drift at high temperatures.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Ungrounded
|
0.125 in
|
12 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1204°C (32 to 2200°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Ungrounded
|
0.250 in
|
4 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Air Probe
|
Super OMEGACLADâ„¢ XL
|
Exposed
|
0.125 in
|
3 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Air Probe
|
Super OMEGACLADâ„¢ XL
|
Exposed
|
0.125 in
|
4 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.125 in
|
8 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
RTD probes that can be cut to the desired length with a standard tube cutter to fit field applications. Plastic plug in tube end protects the wires from sharp edges.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 500°C (-58 to 932°F)
|
Immersion Probe - Cut to Length
|
Class A per IEC60751
|
100 Ω
|
3
|
316 Stainless Steel
|
0.250 in
|
24 in
|
Fiberglass
|
26 AWG
|
40 in
|
Stripped Leads
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe - Cut to Length
|
Class A per IEC60751
|
100 Ω
|
3
|
316 Stainless Steel
|
0.250 in
|
24 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe - Cut to Length
|
Class B per IEC60751
|
100 Ω
|
3
|
316 Stainless Steel
|
0.250 in
|
24 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe - Cut to Length
|
Class A per IEC60751
|
100 Ω
|
4
|
316 Stainless Steel
|
0.250 in
|
24 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe - Cut to Length
|
Class A per IEC60751
|
100 Ω
|
3
|
316 Stainless Steel
|
0.250 in
|
24 in
|
PFA
|
26 AWG
|
240 in
|
Stripped Leads
|
Thermocouple probe has a metal transition between the sensor & cable. Cable has BX armor or Stainless Steel Overbraid to protect from damage and a mini connector attached.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 1070°C (32 to 1960°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.125 in
|
12 in
|
PFA with Armored Cable
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 920°C (32 to 1690°F)
|
Air Probe
|
304 Stainless Steel
|
Exposed
|
0.062 in
|
4 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.010 in
|
36 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.020 in
|
36 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 920°C (32 to 1690°F)
|
Air Probe
|
304 Stainless Steel
|
Exposed
|
0.062 in
|
12 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
None
|
0 to 100°C (32 to 212°F)
|
None
|
2252 Ω
|
±0.1°C
|
2
|
PVC
|
Phone Plug
|
10 ft
|
None
|
22 AWG
|
1
|
Shrink Tube
|
|
Thermistor
|
None
|
0 to 100°C (32 to 212°F)
|
None
|
2252 Ω
|
±0.1°C
|
2
|
PVC
|
Phone Plug
|
10 ft
|
None
|
26 AWG
|
1
|
Vinyl Tipped
|
PFA-Coated RTD Probes for Harsh Chemical Applications
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
2
|
304 Stainless Steel
|
0.062 in
|
4 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-30 to 350°C (-22 to 662°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.062 in
|
4 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
|
RTD
|
-30 to 350°C (-22 to 662°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.062 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.062 in
|
9 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
4
|
304 Stainless Steel
|
0.062 in
|
4 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
General use, straight thermistor probes can be used as-is or adapted with mounting accessories. Multiple resistances and accuracies available. Probes have extension cables.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
-80 to 150°C (-112 to 302°F)
|
Immersion Probe
|
±0.2°C
|
3000 Ω
|
304 Stainless Steel
|
0.125 in
|
4 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
Stripped Leads
|
10,000 Ω @ 25°C
|
40 in
|
2 in
|
Stainless Steel
|
1/4 in
|
General Purpose Probe
|
Standard
|
||||
|
Thermistor
|
-80 to 150°C (-112 to 302°F)
|
Immersion Probe
|
±0.2°C
|
10,000 Ω
|
304 Stainless Steel
|
0.250 in
|
2 in
|
PFA
|
26 AWG
|
80 in
|
Stripped Leads
|
|
Thermistor
|
-80 to 150°C (-112 to 302°F)
|
Immersion Probe
|
±0.2°C
|
10,000 Ω
|
304 Stainless Steel
|
0.250 in
|
4 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
|
Thermistor
|
-80 to 150°C (-112 to 302°F)
|
Immersion Probe
|
±0.2°C
|
10,000 Ω
|
304 Stainless Steel
|
0.125 in
|
2 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
Small diameter probes that provide the most sensitive response to temperature. Type K with 310 or 316 SST sheaths and a compact transition junction.
Product Number | Category | Sensor Type | Thermocouple Type | Process Temperature Range | Sensor Application | Accuracy | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
150 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
200 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
300 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
500 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Ungrounded
|
0.50 mm
|
150 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
Thermocouple probes with lead wire. Sheaths made with Omegaclad XL material. These probes have superior long-term stability and low drift at high temperatures.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Air Probe
|
Super OMEGACLADâ„¢ XL
|
Exposed
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.062 in
|
3 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.062 in
|
8 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Air Probe
|
Super OMEGACLADâ„¢ XL
|
Exposed
|
0.125 in
|
3 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
none
|
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 450°C (-58 to 842°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
2 in
|
Fiberglass
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
2 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 450°C (-58 to 842°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
4
|
304 Stainless Steel
|
0.250 in
|
2 in
|
Fiberglass
|
26 AWG
|
120 in
|
Stripped Leads
|
none
|
1/16",or 1.5mm diameter RTD probes available with lead wire, 3-prong connector, or handle probe. Small size provides maximum sensitivity and response time to temperature.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Probe Diameter | Sheath Housing Material | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
6 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
4
|
0.062 in
|
304 Stainless Steel
|
9 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
12 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
18 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
24 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
Class A, pt100 RTD probes have a copper tip that provides enhanced temperature response. Available in 2, 3, or 4 wire configurations and various sizes.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
9 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class A per IEC60751
|
100 Ω
|
4
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class A per IEC60751
|
100 Ω
|
4
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
9 in
|
PFA
|
26 AWG
|
40 in
|
3-Prong Standard Connector
|
none
|
Spring-loaded quick-connect bayonet style RTD probes with armored cable. Commonly used in extruder & molding equipment. Both Straight and bend options available.
Product Number | Category | Process Temperature Range | Sensor Application | Process Connection Size | Accuracy | Nominal Output | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
3.5 in
|
PFA with Armored Cable
|
60 in
|
Spade Lugs
|
90 Degree Angle Probe
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
2.25 in
|
PFA with Armored Cable
|
60 in
|
Spade Lugs
|
Straight Probe
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
2.25 in
|
PFA with Armored Cable
|
60 in
|
3-Prong Standard Connector
|
Straight Probe
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
3.5 in
|
PFA with Armored Cable
|
60 in
|
Spade Lugs
|
Straight Probe
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
3.5 in
|
PFA with Armored Cable
|
60 in
|
3-Prong Standard Connector
|
Straight Probe
|
Class B, pt100 RTD probes have a copper tip that provides enhanced temperature response. Available in 2, 3, or 4 wire configurations and various sizes.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
9 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
12 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
18 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
24 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
none
|
Most Thermocouple Probe Styles, Handle, Molded Junction, Quick Disconnect, Heavy Duty, and Well KHSUP, KTSUP, KQSUP, TJ36CASUP, NB1-CASUP
Product Number | Thermocouple Type | Type of Sensor | Process Connection | Process Connection Size | Sheath Housing Material | Junction Type | Probe Diameter | Probe Length | Insulation | Termination Connection Type | Additional Feature 1 | Additional Feature 2 | Application of Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Exposed
|
1/4 in
|
12 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Grounded
|
1/4 in
|
12 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Grounded
|
Not Applicable
|
24 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Ungrounded
|
1/4 in
|
12 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Ungrounded
|
Not Applicable
|
18 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
Small diameter sensor allows for use in tight spaces, hermetically sealed and available in three resistances and standard lengths.
Product Number | Category | Sensor Type | Nominal Resistance | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|
|
Thermistor
|
Sealed Tip
|
10000 Ω @ 25°C
|
1 m (40 in)
|
Stripped Leads
|
none
|
|
Thermistor
|
Sealed Tip
|
10000 Ω @ 25°C
|
2 m (80 in)
|
Stripped Leads
|
none
|
|
Thermistor
|
Sealed Tip
|
2252 Ω @ 25°C
|
1 m (40 in)
|
Stripped Leads
|
none
|
|
Thermistor
|
Sealed Tip
|
2252 Ω @ 25°C
|
3 m (120 in)
|
Stripped Leads
|
none
|
|
Thermistor
|
Sealed Tip
|
2252 Ω @ 25°C
|
1 m (40 in)
|
Stripped Leads
|
none
|
Probes with Hastelloy Tips for use at the high pressures and temperatures found in plastic extruders. Available in single and dual element options with 1/2"-20 NF Threads.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Process Connection Size | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Ungrounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Ungrounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
6" Body Length
|
|
Thermocouple
|
J
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
|
Thermocouple
|
J
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
6" Body Length
|
|
Thermocouple
|
K
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
Thermocouple probe connects directly with your computer via the provided USB connector. Free software allows for temperature data to be displayed directly on your screen.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 315°C (32 to 600°F)
|
USB Thermocouple Probe
|
Inconel® 600
|
Ungrounded
|
0.250 in
|
4 in
|
72 in
|
USB Connector
|
|
Thermocouple
|
K
|
0 to 315°C (32 to 600°F)
|
USB Thermocouple Probe
|
304 Stainless Steel
|
Ungrounded
|
0.250 in
|
8 in
|
72 in
|
USB Connector
|
|
Thermocouple
|
K
|
0 to 315°C (32 to 600°F)
|
USB Thermocouple Probe
|
Inconel® 600
|
Ungrounded
|
0.250 in
|
18 in
|
72 in
|
USB Connector
|
|
Thermocouple
|
K
|
0 to 1000°C (32 to 1832°F)
|
USB Thermocouple Probe
|
Inconel® 600
|
Ungrounded
|
0.250 in
|
18 in
|
72 in
|
USB Connector
|
|
Thermocouple
|
K
|
0 to 315°C (32 to 600°F)
|
USB Thermocouple Probe
|
Inconel® 600
|
Ungrounded
|
0.250 in
|
24 in
|
72 in
|
USB Connector
|
Thermocouple probe has a section of coiled 304 SS cable that allows the probe to extend and retract as needed for use in steam washdown and other applications.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Autoclave
|
304 Stainless Steel
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Autoclave
|
304 Stainless Steel
|
Ungrounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
J
|
0 to 440°C (32 to 825°F)
|
Autoclave
|
304 Stainless Steel
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
J
|
0 to 440°C (32 to 825°F)
|
Autoclave
|
304 Stainless Steel
|
Ungrounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
|
Thermocouple
|
K
|
0 to 920°C (32 to 1690°F)
|
Autoclave
|
304 Stainless Steel
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
none
|
Immersion probe with bracket for easy mounting. Often used in appliance & lab temp applications up to 500°C. Great for air, gas, or liquid measurement.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-70 to 500°C (-95 to 930°F)
|
Air Probe
|
Class A per IEC60751
|
100 Ω
|
2
|
316 Stainless Steel
|
5.00 mm
|
51 mm
|
Fiberglass
|
24 AWG
|
6 in
|
Stripped Leads
|
|
RTD
|
-70 to 500°C (-95 to 930°F)
|
Air Probe
|
Class A per IEC60751
|
100 Ω
|
2
|
316 Stainless Steel
|
5.00 mm
|
152 mm
|
Fiberglass
|
24 AWG
|
6 in
|
Stripped Leads
|
|
RTD
|
-70 to 500°C (-95 to 930°F)
|
Air Probe
|
Class A per IEC60751
|
100 Ω
|
2
|
316 Stainless Steel
|
5.00 mm
|
51 mm
|
Fiberglass
|
24 AWG
|
6 in
|
Stripped Leads
|