Resistivity and Conductivity Tester CDH-93 CDH-93
Resistivity and Conductivity Tester is rated 4.0 out of 5 by 1.
  • y_2020, m_10, d_24, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_CDH-93, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 3ms
  • REVIEWS, PRODUCT
  • Compact and Lightweight
  • Single Button Operation
  • Automatic Calibration
  • Easy Electrode Replacement
  • Dustproof and Waterproof NEMA 6 (IP57)
  • Large LCD
5 Year Warranty

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Measurement Type
Range
Accuracy
Supply Power
Features


Product Specs

The CDH-93 resistivity and conductivity meter uses advanced automatic frequency conversion and booster technology to keep the electrode constant the same in different solution strengths. It can meet measuring accuracy in the whole range of this electrode by using only the one-point calibration function. The result is the high performance and the lowest cost.

Specifications
Range
    Conductivity: 5 to 50.0µ S/cm, 50 to 500µ S/cm, 0.5 to 5.00 mS/cm, 5.0 to 50.0 mS/cm
    Resistivity: 2 to 20 M?-cm
    TDS: 0 to 35.0 g/L
    Salinity: 0 to 25.0 ppt
    Temperature: 0 to 50°C (32 to 122°F)
Accuracy:
    Conductivity/Resistivity: ±1.0% full scale temperature; ±0.5°C
ATC Range: 0 to 50°C (32 to 122°F)
Calibration: One-point calibration (1413µ S/cm)
Power: Two (2) CR2032 3V lithium ion batteries (included)
IP Standard: Waterproof and dustproof meets NEMA 6 (IP57) standard
Auto Power Off: After 10 minutes (override available)
Dimensions:
    Meter: 148 L × 29 W × 14 mm D (5.82 x 1.14 x 0.55")
    Carrying Case: 168 L × 96 W × 28 mm D (6.61 x 3.78 x 1.10")
Weight with Case: 178 g (6.28 oz)

Rated 4 out of 5 by from Good Tool. Poor instructions. So-so support. This will be a good tool for the intended purposes. It is easy to use and appears accurate and durable, but the documentation that comes with it is very meager. I called with a few questions. One was answered other wasn't. Didn't receive a return call or a response to an online support question submitted as a follow up.
Date published: 2017-05-02
  • y_2020, m_10, d_24, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_CDH-93, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT

Conductivity: 5 to 50.0µ S/cm, 50 to 500µ S/cm, 0.5 to 5.00 mS/cm, 5.0 to 50.0 mS/cm. The resolution is ±1% of full scale. Does that mean the accuracy is ±0.01x50mS/cm which is ± 0.5mS/cm?

Asked by: Maywu
Thank you for your inquiry about the handheld meter. Yes, this is correct for the accuracy.
Answered by: JC ENGR
Date published: 2020-09-09

The range is 2 megaohms to 20 megaohms correct? Do these come with calibration certificates? How long are the calibrations good for and can we send them to you guys to calibrate periodically before calibrations expire? Do you guys sell a standards?

Asked by: Anonymous
Thank you for your inquiry. Yes the resistivity range is 2 to 20 MΩ-cm. These electrodes are calibrated prior to shipping but calibration certificates are not provided. We can provide a Certificate of Conformance though. Field calibrations should be done at least monthly depending on frequency of use. We do sell calibration buffer solutions for this meter. The part number for the solution is CDSA-1413. For additional inquiries please contact us at flow@omega.com and our pH/Flow engineers will be able to help you.
Answered by: AS Engineer
Date published: 2020-05-21

Do you sell a meter that can read 500 ohms to 20 Megohms?

Asked by: Satch
Thanks for you question. Omega doesn't have a product that goes to the ranges you have specified. please contact the flow department to see if they would have other options?
Answered by: application engineer je
Date published: 2020-02-27

My sample I need to test, should I dilute it? The product is 'syrup' thick.

Asked by: AnnaLynne
Thank you for your inquiry. Please contact our Flow Engineering department with this request as they will need some more information about your application before advising whether dilution is necessary. You can email them at flow@omega.com.
Answered by: AS Engineer
Date published: 2019-09-18

Hi! Is the minimum resistivity 2 ohms or 2M ohms?

Asked by: SHERRI
Hi, Thank you for your question. The minimum resistivity is 2 M ohms.
Answered by: Application Engineer HB
Date published: 2019-06-25
  • y_2020, m_10, d_24, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_CDH-93, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 2ms
  • QUESTIONS, PRODUCT
  • CE Icon CE

en-US
en
Save Configuration